Page 31
Rev C August 2009 Page 2.9 Digital Projection TITAN 1080p-600/700, Reference, Ultra Contrast User Manual 2. Installation Lens charts continued Full height image 1.6:1 Use the chart below to choose which lens best suits your application. if you need to be more precise, then use the calculations on the page immediately following the lens charts. Notes This chart has a TRF of 1.1, for use with the following images: 1.6:1 feetmetres Screen width 10 20 30...
Page 32
Page 2.10 Rev C August 2009 2. Installation Digital Projection TITAN 1080p-600/700, Reference, Ultra Contrast User Manual Notes This chart has a TRF of 1.33, for use with the following images: 4:3 = 1.33 Lens charts continued Full height image 4:3 Use the chart below to choose which lens best suits your application. if you need to be more precise, then use the calculations on the page immediately following the lens charts. feetmetres Screen width 10 20 30...
Page 33
Rev C August 2009 Page 2.11 Digital Projection TITAN 1080p-600/700, Reference, Ultra Contrast User Manual 2. Installation Notes The Throw ratio for a particular lens is fixed, and assumes that the image fills the width of the DMD. For images that do not fill the width of the DMD, the Throw ratio is effectively increased. To correct for this, a Throw Ratio Factor (TRF) is used. Choosing a lens by calculation For any screen size not listed above, or if you need to be more precise, then use...
Page 34
Page 2.12 Rev C August 2009 2. Installation Digital Projection TITAN 1080p-600/700, Reference, Ultra Contrast User Manual Notes The Throw ratio for a particular lens is fixed, but assumes that the image fills the width of the DMD. For images that do not fill the width of the DMD, the Throw ratio is effectively increased. To correct for this, a Throw Ratio Factor (TRF) is used. Useful lens calculations The following lens calculations may be useful: Throw ratio = Throw distance Screen...
Page 35
Rev C August 2009 Page 2.13 Digital Projection TITAN 1080p-600/700, Reference, Ultra Contrast User Manual 2. Installation Notes Each time a new lens is fitted to the projector, the calibration procedure must be carried out. See Setup menu, in Section 4. Controlling the projector. Make sure the rear lens cap is removed, before fitting the lens. Make sure the front lens cap is removed, before switching on the projector. Be careful not to scratch the lens surfaces. If you do accidentally...
Page 36
Page 2.14 Rev C August 2009 2. Installation Digital Projection TITAN 1080p-600/700, Reference, Ultra Contrast User Manual Notes For more information on using the Lens shift feature, see section 4. Using the menus, Using the control keys. If the lens is to be shifted in two directions combined, the maximum range is somewhat less, as can be seen below. (zoom lens shift shown). full horizontal or vertical shift without distortion combined shift is reduced Shifting the image The normal...
Page 37
Rev C August 2009 Page 2.15 Digital Projection TITAN 1080p-600/700, Reference, Ultra Contrast User Manual 2. Installation Mounting the projector The projector is designed to be used on a flat surface, but the optional rigging frame will allow it to be suspended from a lighting truss or rigging. The four adjustable feet under the chassis allow the projector to be lowered onto a flat surface without any danger of hands being trapped between the bottom frame and the surface. Chassis adjustment If...
Page 38
Page 2.16 Rev C August 2009 2. Installation Digital Projection TITAN 1080p-600/700, Reference, Ultra Contrast User Manual Adjusting the rigging frame Coarse adjustment of projector level should be made by adjusting the length of the supporting wires or chains, or by adjusting the position of the truss or rigging. Once the initial coarse adjustment has been made, fine adjustment can be made by turning the frame adjusters on the rigging frame: To tilt the projector forwards and backwards (pitch...
Page 39
Rev C August 2009 Page 2.17 Digital Projection TITAN 1080p-600/700, Reference, Ultra Contrast User Manual 2. Installation Notes When stacking projectors, the stack MUST be vertical, to ensure that the stresses are distributed to all frame couplings. Make sure that the surface, ceiling or rigging that is to support the projector is capable of supporting the combined weight of all the projectors and lenses (see specification for weights). Do not place heavy objects on top of the projector...
Page 40
Page 2.18 Rev C August 2009 2. Installation Digital Projection TITAN 1080p-600/700, Reference, Ultra Contrast User Manual Notes For more information on selecting an input source, see section 4. Overview, Using the control keys, and Using the menus. SDI not present on earlier models For more information about pin connections and control codes see section 7. Appendix. For more information on input modes see section 4. Overview. Connecting the projector Signal Inputs The following inputs...