Page 31
Chapter 2: Installation GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 27 Figure 2-14 : Wiring the redundant power inputs 3. Tighten the wire-clamp screws to prevent the wires from coming loose. Figure 2-15: Wiring the redundant power inputs 1 2 3 4 5 6 Power 2 Power 1 - + - + NOTE: The wire gauge for the terminal block should be in the range between 12 ~ 24 AWG. For the GE-DSH-82-PoE, A 48VDC, 3A power in put is required for full PoE load on the PoE. Please...
Page 32
Chapter 2: Installation 28 GE-DSH-73/DSH-82 and DSH-82-PoE User Manual forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts. Figure 2-16 : 6-Pin Terminal Block Fault Alarm contact NOTE: The wire gauge for the terminal block should be in the range between 12 ~ 24 AWG. Figure 2-17: Power Fault Alarm trigger description Wiring the Digital Inputs / Outputs (GE-DSH-73) There is another terminal block comprising two sets...
Page 33
Chapter 2: Installation GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 29 Figure 2-18 : DI/DO terminal block of GE-DSH-73 Installing the SFP transceiver The section describes how to insert an SFP transceiver into an SFP slot. The SFP transceivers are hot pluggable and hot swappable. You can plug-in and out the transceiver to/from any SFP port withou t having to power down the Industrial Switch. Shown in Figure 2-19. Figure 2-19 : Plug-in the SFP transceiver
Page 34
Chapter 2: Installation 30 GE-DSH-73/DSH-82 and DSH-82-PoE User Manual Approved GE Security SFP Transceivers GE Security Industrial Switch supports both Single mode and Multi-mode SFP transceiver. The following list of approved GE Security SFP transceivers is correct at the time of publication: o SFP1000SX-220 SFP (1000Base-SX SFP transceiver / Multi-mode / 850nm / 220m~550m) o SFP1000LX-10Km SFP (1000Base-LX SFP transceiver / Single mode / 1310nm / 10km) o SFP100FX1310-TSC-2Km SFP...
Page 35
Chapter 2: Installation GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 31 Figure 2-20 : LC fiber optical cable connects to the transceiver • Remove the transceiver module 1. Make sure there is no network activity by consulting or checking with the network administrator or through the management interface of the switch/converter (if available) to disable the port in advance. 2. Remove the Fiber Optic Cable gently. Figure 2-21 : Pull out the SFP transceiver 3. Turn the handle of the MGB...
Page 36
Chapter 2: Installation 32 GE-DSH-73/DSH-82 and DSH-82-PoE User Manual Figure 2-22: Pull out from the transceiver NOTE: Never pull out the module without pull th e handle or the push bolts on the module. Pulling out the module with too much force could damage the module and SFP module slot of the Managed Industrial Switch.
Page 37
GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 33 Chapter 3 Network Application This chapter discusses how the Switches f unction in various Network environments. A couple sample applications of the in dustrial switch are shown below. Factory Redundant Ring Application
Page 38
Chapter 3: Network Application 34 GE-DSH-73/DSH-82 and DSH-82-PoE User Manual Transportation Networking and Public Wireless Service
Page 39
Chapter 3: Network Application GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 35 X-Ring Application The industrial Switch supports the Rapid Ri ng (X-Ring) protocol that can help the network system to recovery from network co nnection failure within 20ms or less, and make the network system more reliable. The X-Ring algorithm is similar to spanning tree protocol (STP) algorithm but its recovery time is faster than STP. The following figure is a sample X-Ring application....
Page 40
Chapter 3: Network Application 36 GE-DSH-73/DSH-82 and DSH-82-PoE User Manual Coupling Ring Application In the network, it may have more than one X-Ring group. By using the coupling ring function, it can connect each X-Ring fo r the redundant backup. It can ensure the transmissions between two ring groups not to fail. The following figure is a sample of coupling ring application. Dual Homing Application Dual Homing function is to prevent the connection lose from between X-Ring group and...