Page 21
IMI 66-064 Description Of Prgrammable Features NIGHT TRANSFER (OF RINGING) The day, or normal, ringing of incoming lines can be : transferred to a particular station or stations (chosen through class of service programming) for off-hour or special purpose answering. The night transfer mode can only be activated from station 10. Night transfer of ringing can be assigned to specific stations using system or administration programming. It is then turned on or off by using system or administration...
Page 22
IMI 66-064 Description Of Prgrammable Features line selection is enabled by the system or administra- tion class of service programming. SECURE OFF-HOOK VOICE ANNOUNCE With the secure off-hook voice announce (SOHVA) fea- ture, a secure announcement can be made from one station to another station that is off-hook or busy on a call. A station being operated in a handsfree mode cannot receive a SOHVA announcement. A station must be equipped with a telephone that includes SOHVA capability to...
Page 23
:. .,/ IMI 66-064 -,.yT:,~ .‘... ” .:‘:.;, Description Of Prgrammable Features TONE OR VOICE SIGNALLING (INTERCOM) Intercom calls can be tone signalled or voice signalled as desired. The tone signalled intercom call must be answered by lifting the handset. The voice signalled intercom call can be responded to in a handsfree man- ner. The class of service programming determines which signalling method is employed as the primary method when an intercom call is made. The alternate method is...
Page 24
IMi 66-064 Installation . . I l l l l 0 a CHAPTER 3 INSTALLATION SECTION 1 STANDARD INSTALLATION DETAILS MOUNTING CONSIDERATIONS The common equipment cabinet should be attached vertically to any sturdy, flat, surface or vertically rack mounted if desired. Cabinet must be located within six (6) feet of a proper electrical outlet. The system requires a dedicated 117VAC 15 AMP circuit, with a third-wire ground, supplied to a standard electrical outlet (NEMA 5-l!%). The distance between...
Page 25
installation IMl66-664 yodels NO820 and N1024 Model NO61 6 Model NO308 Figure 3-1. Mounting Details _ _ 3-2
Page 26
lMli 66-064 Installation AC POWER CONNECTION - Employ a dedicated 117VAC 15 AMP circuit, with a third-wire ground, supplied to a standard electrical outlet (NEMA 5-133) for the AC power connection. AC power connection is illustrated in Figure 3-2, shown on the following page l A plug-in power line surge protector should be installed between the power cord and the AC outlet. l Do not connect the AC power cord until the installation has been checked. l To apply AC power, connect the power cord...
Page 27
Installation IMI 66-064 ’ TYPICAL EARTH GROUND (METAL COLD WATER PIPE, BUILDING FRAME,..ETC.l Figure 3-2. AC Power Connection and System Grounding LINE CONNECTIONS The common equipment cabinet line terminations are standard modular plug/jack connections. Each modular jack (2-6) provides termination for two lines. Modular jacks 2 and 3 also provide termination for an auxiliary pair in addition to the two outside lines. CO line terminations can be at a type 66M-xx connector block or at...
Page 29
Installation IMI 66-064 I Table 3-2a. Station Connections (Model N0616, N0820, and N1024) EN I I I I I EN 1 15 1 127 1 I --_ .-._ -..... _-- .- -. -- , -..TA YELLOW ORANGE-BLACK 1 I12 124 1 BLACK BLACK-GREEN I 13 I 38 125 I VOICE GREEN 16 28 131 I I I I .TA 1 YELLOW 1 I I I 1 ZK EN 21 33 , I i 3-6
Page 30
, IM; 66-064 Installation ‘ / Table 3-2b. Station Connections (Model N0308) ( Data I 1 6 1 No Connection 3-7