Home > Comdial > Communications System > Comdial Executech Model 0616x, 0816x Electronic Key Systems Instructions Manual

Comdial Executech Model 0616x, 0816x Electronic Key Systems Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Comdial Executech Model 0616x, 0816x Electronic Key Systems Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 133 Comdial manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							IMI 66-031System Programming
    SMDR ANP COS PRINTOUT
    SMDR PRINTOUT
    A data printer can be connected to the system to be
    used for printing station message detail recording
    (SMDR) information. The SMDR data is provided
    automatically as it is generated. No intervention is
    required to obtain the printout. The data is for-
    matted as shown in Figure 3-2. Either an 80
    column or a 
    40-column printout line can be
    selected through the system COS programming.
    COS PRINTOUT
    When a data printer is connected to the system to be
    used for printing SMDR data, it can be commanded
    from station 10 to also print a record of the current
    COS configuration. Partial or complete printouts can
    be obtained. When the printer is being used to obtain
    a COS printout, the SMDR printout is temporarily
    halted; however, SMDR data collection is continued
    by the system during a COS printout operation. If
    more than two calls are logged for any one tine
    during the halt, call records may be lost. Typical COS
    printouts are shown in Figure 3-3.To obtain the COS printout,l
    Press ITCM * 7 4 6 +% (base level if not active)
    PRINT SYSTEM AND LINE COS PLUS TOLL RESTRICTIONSl
    Press memory key to select type of printout desired.
    The COS printout will begin immediately.
    To abort printout,l
    Press memory key A9.
    To exit COS 
    prfntout mode,l
    Press f MONITOR.
    - -- -----3-8 
    						
    							STATION NUMBER
    40 COLUMN
    PRINTOUT
    LINES
    1T [CARRIAGE RETURN! (LlNEj
    2X &ARRlAGE FE~URN 1 I--,I-
    MONTH/DAY/YEARINITIATE TIME-HOUR : MINUTE
    (24 HOUR REAL TIME CLOCK)
    \J
    DIALED DIGITS-UP TO MAXIMUM OF 32
    (ACCOUNT CODES ARE ISOLATED BY l OR # SYMBOLS
    NOTES
    1. CARRIAGE RETURN AND LINE FEED IMMEDIATELY
    ;O$.OW LAST PRINTED CHARACTER ON EACH
    9782200
    OUTGOING CALL24 2 
    12/05/06 17:Ol.5
    (WITH ACCOUNT CODES)1~~33456789’0#‘7412580#9831’w
    AC POWER FAILURE AND
    RESTORATION
    2FFTlME l * 12/05/8617:03.;. 12/05/06 17:08
    Flgure 3-2. Station Message Detail Record Prlntout Format 
    						
    							IMi 66-031System Programming
    SYSTEM COSTOLL RESTRICTION TABLES
    PAUSE TIRE2.0 SECPULSE DIAL 20 PPS
    FLASH TIME720 MSECHOLD RECALL 240 SEC
    TABLE1DENY11
    2 0
    3 
    -4
    LINE 
    COSLINE PRV TYPE PU- HOLD TOLL
    RLSLSE.SOMS TABLESTABLE 2 ALLOW
    1 17034344664
    2 17039493113
    3 1985
    4 1831
    1C.O.2C.O.3C.O.4 xc-0.5 x
    AUX
    6NONE7PABX x
    8 XPABX x
    STATION 13
    TOLL RESTRICTION
    P.A. ENABLE
    PRIME 
    LINE123 6
    123 6
    123 6
    123 6
    78X
    456X456
    123
    1
    LINE12345678
    RING X
    DELAY RING X
    NITE RING
    ACCESS DENY
    ORIGIN DENYPRIVACY 
    RLS
    ALL CALL
    RECEIVE
    ORIGIN
    GROUPABCD
    ABCD
    X
    X
    BUTTON12345678LINE NO.2 3 4 1 6 7 8 5TABLE3 
    DENY1 8313
    2 5891
    34TABLE 4 DENY
    1 91
    2 90
    :TABLE 5 ALLOW
    1 91804
    2 917034341133
    3 
    91703494?7??
    4TABLE6 ALLOW
    1 1800
    2 91800
    :TABLE 7 DENY
    11
    2 2
    3 3
    4 91985
    TABLE 8 ALLOW
    14
    2 5
    3 6
    4 17039491234
    Figure 3-3. Typical COS Printout
    (Model 0616X Shown. Model 0616X same except six 
    lines)
    3-10 
    						
    							IMI 66-031System Programming
    SYSTEM CLOCK INFORMATION
    SElTlNG THE CLOCK
    1.Press ITCM, then dial +# #.
    2.Dial clock date with keypad keys.l
    Values less than 10 must be dialed asox.
    l
    Hours must be expressed in 24-hour for-
    mat..
    Enter: YEAR MONTH DAY HOURMINUTE
    Example: 8808061530 (August 6,1988,3:30 PM)
    3.If SMDR printer is installed and operating, clock
    date will be printed as illustrated in following typi-
    cal example:
    W 01/08/86 16:00
    4.Reset minutes setting, if necessary, as follows:l
    Repeat step 1.l
    Dial new digits, and press #.l
    A new clock date printing will occur.
    CHECKING THE TIME SETTING
    A printing of the current clock date can be obtained
    from station 10 whenever needed as follows:l
    Press ITCM and dial * # #.A clock date printing will automatically occur once
    each 24-hour period. This daily, automatic printing
    will formatted as follows:
    W MO/DY/YR 0O:OO (current date and 0O:OO hours)POWER 
    INTERRUPTIoN
    The system clock will continue to run for at least 30
    minutes after AC power has been removed form the
    system. If power is restored within the 
    30-minute
    backup period, the 
    following.printing sequence will
    occur:
    OFF 
    TIME +I& MOlDY/YR iiR:Mti
    (time of power outage)
    +#+ MOlDY/YR HR:MN(time of poker return)
    If power is not restored within the backup period, the
    following printing sequence will occur when the
    power is restored.
    CLOCK 
    NOT VALID
    ++G% 12/01/86 0O:OO(default clock date)
    The clock will begin running from the default date. It
    must be reset to the current date per the instructions
    above.
    :
    3-l 1 
    						
    							IMI 66-031
    SYSTEM SPEED DIAL PROGRAMMING
    System Programming
    Ten (10) system speed dial numbers can be stored
    from station 10 for use at all stations in the system.
    To store speed dial numbers,To end procedure,l Press MONITOR
    l Press 
    ITCMt. .
    l
    Perform the following steps:l Press SAVE.
    l
    Dial storage location (1-O) from keypad.
    Press line select key (program keys 
    Bl-S6)l
    SYSTEM SPEED DIAL INDEX
    (enter programmed numbers)
    1
    2
    to identify line to be preselected during opera-3
    tion (otherwise system will pick prime line or
    last line used).4
    *Dial speed dial number from keypad (up to31 digits). .‘.5
    -Dial 1 - 0, #, and +K as required.6l
    Press HOLD to store pause if required.
    7
    -Press RECALL to store flash if required.
    Repeat the preceding steps for each number8-
    to be stored.9
    2
    3-12 
    						
    							IMI66-031System Programming
    Table 
    3-l. System COS Programming Reference
    PROCEDURE
    Note: Circle the record values at right
    before performing the procedure given below.
    1. BASE LEVEL ENTRY.PressfTCM*746+
    2PULSWONE OR TONE ONLY DIALING MODE. Presst.
    Press 0 for tone dialing.Press 
    1% pulse/tone dialing
    .
    Press*
    3.FIRST ATEMPTED INTERCOM SIGNALING MODEPress Al3 for tone signalling .
    .Press Al4 for voice signalling
    .Press*
    4. TIME MERVAL FOR PROGRAMMED PAUSE.Press4
    .Press one key
    KEY 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 
    I 9 I 0SEC. 
    ~0.5~1.0)1.5~2.0(3.0)5.0~7.5~1o.~15.~2o.
    RECORD
    (Shading Denotes Default Value)
    Note: Circle the desired value
    for the system being programmed.
    I;=11.:‘:~~~~~~-gPULSE/TONE SWITCHABLEI
    ~~~~~&~~~~-gg@$@!J .._._._... ._. . . . . . . . . . :. . . . _ . . ..: :.. 1
    TONE SIGNALLINGSECONDS
    0.5 
    p;g$ 1.5 1 2.0 1 3.0 5.0 7.5 10. 15. 120..Press 
    Y
    5.PULSE DlAL CHARACTERISTICS - PPI AND MAKE/BREAK.Press5
    .Press 
    1= 10 PPI and 60140.Press 
    2y20 PPI and 60140.
    Press*
    6. HOOKSWITCH FIASHIRECALLTIME INTERVAL.Press6
    KEY 
    I 1 1 2~3~4~5~6~7~8~9~ 0
    SEC. 
    I -08 -30 .50 .60 .75 .875 1.0 1.5 2.0 3.0
    .Press one key:
    .Press*
    7. HOLD RECALL TIME INTERVAL.Press7
    .Press one key:
    KEY 1 1 
    ( 2 1 3 ) 4 I 5 I 6 I 7 1 8 ( 9 I 0
    SEC. 30 80 90 120 180 240 300 360 420 
    noneSECONDS
    90 1120118012401300 
    360142O(nona.Press 
    t
    3-13 
    						
    							1MI 66-031System Programming
    0. TOLL RESTRICTION RtQlhMtNTS.
    Set system toll restriction requirements per instructions
    given on Table 3-4Record 
    all toll restricbn data on table 3-4.
    9. SMDR DATA SPEED BAUD RATE. 
    Press3=3oDbaud.
    Press OZlO baudI. Press1 
    =7!5Omsec..
    Press ,fl-2 sec.
    No&: If a timeout occurs during the program-
    ming sequence, 
    perform base level entry again
    and proceed at any program step. 
    						
    							IMI 66-031System Programming
    Table 3-2. 
    Line COS Programmlng Reference
    PROCEDURE
    NUltEnter the information In the box at right before
    performing the pfugram pfucadwes givan below
    1. BASE LEVELENTRY.Press ITCM * 746 S2 PRNACY STATLJS.
    Press 6. All line6 private.
    Press keys for non-private..(Bl-86 for model 0616x). (B1-86formodelO616X). Press*
    3. SELECT LINE FOR PROGRAMMING.
    Press 81-88 (model 0816X).
    Press BTi6 (model 0616X)4. SPECIFY LINE TYPE. 
    Pressby: O=Disabledl.he
    1 = Auxiliary Line
    2=COtine
    3=PBXLine5.ASSIGN TOLL TABLES TO LINE. Press memory keys:
    Al-A8 = Tables l-8
    6. DIALING MODE OF LINE.
    Press 6 = pulse/tone dialingQ-.Press 7 = ton8 only dialing7. ABANDONED HOLD RECALLTIME. Press8=5Omsec. Press 
    6Y3C0 msec.
    8.SELECT NEXT LINE FOR PROGRAMMING.
    Press Bl-B8 (model 0616X).
    Press ByB6 (model 0616X)
    9. END LINE g PROGRAMMING
    . Press S MONITORNOTE: 
    If a timeout occurs during the ptvgrammlng seqoence, perform base level entry again and proceed at any
    progmm step.
    RECORD
    (Shading Denotes System Default Values)I
    NOlECheck each line number block for rhe fine featwu that is sdIWrfte in the calling number and locaffon status.
    NON-PRIVATE NON-PRIVATE
    DISABLED 1/
    RESTRICTION RESTRICTION
    CALLING NO. CALLING NO.
    Change page 
    41913-65 
    						
    							IMI 66-031System Programming
    Table 3-3. Statlon COS Programming Reference
    (Copy 
    this sheet as required)
    PROCEDURE
    Circle or enter the record v&es st right before
    RECORD
    Enter lnfotmstion or circle desin?d veh8 below before
    2. 
    DlALTWO-DIGITPORT NUMBER
    . Press RECALLINTERCOM NUMBER
    4. CONFIGUF& PA PORT (opti
    [(06,6X)!, 12 (3 14 15 16 I~~M~ji&j$jj~. . . . _ ..:..:c...: ::. . . . . . . . . . . . .
    ressBl-B6(model D616X). Press4
    (0816X) 
    11 /2 13 (4 15 16 17 1. Press6
    .
    Press Bl-B6 (model D616X).
    Press By-& (model 0816X) 
    						
    							IMI 66-031System Programming
    Table 3-3, STATION COS PROGRAMMING REP ERENCE (Continued)
    (Copy this sheet as required)
    PROCEDURE
    circle or enter therecordvalues at right
    14. ALL 
    CALLAND ZONE PAGING
    .Press # lTCM to clear allcall..
    Press keys: Bl-B4 = receive A. B, C, and all-call.
    Press keys: BS-B8 = originate A. B. C and allcall
    0 Dial l-6 (0616X)
    . Dial 
    147&16X)
    usedkeyand light. Press*
    17. PROGRAM NEXT 
    STATlON.Repeat procedure from step 218. END 
    P&&AMMING.Press MONITOR
    NO7E If a timeout occurs during the progmmmfngsequence, perform base level entry again and
    proceed at any progmm step.