Home > Comdial > Communications System > Comdial Executech Model 0616x, 0816x Electronic Key Systems Instructions Manual

Comdial Executech Model 0616x, 0816x Electronic Key Systems Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Comdial Executech Model 0616x, 0816x Electronic Key Systems Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 133 Comdial manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							IMI 66-031Installation
    Table 2-l. KSU To Station Wring.I
    ----.----a-l.“mI ---.I.- Y-L. I_-_.STATION
    GREEN-WHITBGREEN 5RED6YEUDW 7 
    !BLACK 6 
    hers~mzu.1 Is-.--wmllt-JUIt
    SLATE-WHITE65
    RED-BLUE31BLUE-RED66RED-ORANGE32.ORANGE-RED77
    RED-GREEN,
    GREEN-REDRFCLRRVOICE
    PAIR
    DATA
    PAIRVU&C “n==- 122 .PAIRRED 1;
    xtYEUOW 11
    BLACK 12CREEP l * *_..--- -_--
    BROW..-..,,.,1141______RED-SLATE1__t65nhTA1241__--
    DATA1 YEUDWn 10iiI-n.-SLATE-RED 1DAID
    :K-BLUE36 i
    15
    16
    ORANGE-YELLOW1
    YELLOW-GREEN,643
    GREEN-YELLOW18r-.8x
    YELLOW-BROWN.19U
    BROWN-YELLOW1919Y!EEIYELLOW-SLATE.2645IDATA
    SLATE-YELLOW20llilrn,
    VII31 FT-RL IIFA6SPARE
    I“rn”bIIYELLOW 1 29
    I -
    I =+UCK
    IIII-.-I19I1481COMM.1CONTACT1t--UjTIPGREEN45GREEN-VIOLETI-n”-
    TELCOI-RIINGRED46LINE6 
    fAYELLOW47Al
    BLACK461III --~~--~-- IVIOLET-SIATE13s159)POWER1TIPCDARFGREEN49SLATE-VICRED56)LET 1 --
    I 25 1 FAIL 1 RING 1 “’ -‘=-
    :
    2-7 
    						
    							Installation
    CHECKOUT
    Check the KSU and telephone installation for proper
    operation by performing the following actions.
    Resistance 
    Check
    Make the following resistance measurements at the Sta-
    tion connector blocks under the following conditions.l
    AC power cord disconnected from electrical outlet.l
    KSU connected to station connector blocks.l
    Stationswired, and wiring punched downon blocks.l
    Bridging clips removed from blocks to isolate sta-
    tions from common equipment.
    1.Measure the resistance of each installed sta-
    tion and wiring from the station side of the con-
    nector blocks. Resistance values will vary with
    cable length and station type but should be
    within the following limits. Readings which are
    outside of these limits indicate a possible wiring
    or station problem.
    2.
    VOICE PAIR:
    (40 OHMS MIN.-150 OHMS MAX.)
    DATAPAIR:
    (0.3 OHMS 
    MIN.-100 OHMS MAX.)
    Measure the resistance of the KSU and cablesfrom the KSU side of the station connector
    blocks. Resistance values should be within the
    following limits.
    MEASURFD PAIR
    VOICE PAIR
    DATA PAIR
    Voltage Check
    MEASURED KSURFSISTANCF IN OHMS40-50
    0.3 - 0.5
    Make the following voltage measurements at the station
    connector blocks under the following conditions:
    *Bridging clips installedl
    AC power connected to the common equipment
    Measure the voltage across one voice line and one data
    line and then across the other voice line and the other
    data line for each even and odd station. The measured
    voltage must be as follows:
    UNIT UNDtR66Mxx BLOCKMt I tH LtADMEASURtD
    TESTCONNECTIONPOLARITYVOLTAGE
    TYPICAL EVEN
    Voice 1I(+I
    STATlONData 3I-1. +33+&5vDcI
    (Repeat for
    each even sta.)
    TYPICAL ODD
    STATION
    (Repeat for
    each odd sta.)
    voice2
    Data 4
    Voice5
    Data7
    Voice 6
    Data 8
    (+I_
    t-1+33+1-SVDC
    (+II-)-33+I-5VDC
    (ii
    t-1-33+/-5VDc
    Variant readings can indicate a possible wiring, station,
    or common equipment problem.
    General Check
    1.
    2.
    3.
    Check the red light emitting diode (LED) sys-
    tem status indicator.
    Be sure that it is on steady.If it is off or flash-
    ing, disconnect and reconnect the AC power
    plug.If the indicator is still not on steady, referto the Failure Analysis Flow Chart found in
    Chapter 4.
    Refer to the station User’s Guide for operating
    information.
    Perform a general operational test of the sys-
    tem by exercising the systemfeaturesfrom sta-
    tion port 10 or 11. Operational parameters are
    per the system default conditions as detailed inChapter 3 until COS programming is per-
    formed.
    Once the basic system is verified as operation-
    al, perform the COS programming.
    :
    2-9 
    						
    							IMI 66-031System Programming
    CHAPTER 3
    SYSTEM PROGRAMMING
    GENERAL INFORMATION
    Class Of Service (COS) programming consists of
    setting the Class Of Service (COS) operating con-
    ditions. COS programming is divided into the fol-
    lowing three major categories: System COS, tine
    COS, and Station COS.
    All COS programming commands must originate at
    station 10. No COS programming commands can
    be accepted from any other station connected to the
    system. COS programming causes station 10 todefault to a square condition (line select key 1
    selects line 1, key 2 selects line 2, etc.). It is recom-
    mended that station 10 always remain in a square
    conditionto avoid possible programming confusion.
    COS programming does not require that a sequen-tial process be followed once the base level
    program entry mode has been established except
    where noted herein.
    The system defaults to preset characteristics when
    it is initially powered up or whenever programmed
    to do so.If the default characteristics, or any otherpreviously set characteristics, are satisfactory,
    those portions of the programming sequence may
    be omitted.
    Prior to taking any programming action, record the
    system, line and station COS conditions on Table
    3-1,3-2, and 3-3 (included at the end of this chap-
    ter). Also, record all toll 
    restdction requirements on
    Table 3-4.THE PROGRAMMING STEPS MUST BE PER-
    FORMED WITH LESS THAN 17 SECONDS OF
    DELAY TIME BETWEEN KEYSTROKE OPERA-
    TIONS. A delay of longer that 17 seconds causes
    the KSU programming mode to time out.
    Flgure 3-3 found at the end of this chapter provides
    a quick-reference flow diagram of the class of ser-
    vice programming requirements.
    Programming is the same for both the model 0616X
    and 0816X key systems. The only difference be-tween these two models is the number of lines
    which each serves (six or eight).
    BASE LEVEL PROGRAM ENTRY MODE
    The first step in a COS programming sequence is to
    enter the base level programming mode. Once in
    this mode, COS can be set as desired.
    1.Press ITCM. The dial tone will sound.2. Press the following keys in sequence: 
    8 7 4 6.
    The dial tone stops and a tone burst sounds to in-
    :
    3.
    c&ate that the base level programming mode is
    entered.
    Press 
    *. The dial tone will return as a confirma-
    tion that the base level mode is active.
    CLASS OF SERVICE DEFAULT
    The system can be defaulted to a standard class of
    service per the following procedure.1. Press 
    ITCM.
    2.Press the following keys: * 7 4 6 * # 0 *3. Press MONITOR.
    The following system default conditions are set:-
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    All lines are DTMF
    Voice signalling attempted first when inter-
    com call is made
    1 sec. pause time
    2 sec. dial tone recall time
    30 sec. recall from hold
    All lines private
    All lines are CO lines
    No toll restriction set
    300 msec. held call abandon time
    No ringing line preference enabled
    No 
    prtme line is chosen
    DSSBLF port is disabled
    PA port is disabled
    No delayed ringing enabled
    No access denied
    No origination denied
    No automatic privacy released
    Day and night ringing patterns set as follows:
    -station 10, 4 7, and 24 all lines
    System-wide, all call paging in zone D
    Printer port set for 110 baud data rate
    Line select keys l-n selects lines l-n
    (squared pairing)PROGRAMMING KEYS
    Figure 3-l illustrates the programming keys called
    out in the following procedures. 
    						
    							IMI 66-031System Programming
    Al -
    A2-
    A3 -
    A4 -
    A5 -
    A6 -
    A7 
    -B5 
    -
    84 -
    Bl -
    10-o
    0100
    El30
    0
    0
    00
    0
    0
    O-0
    I
    4’
    ,
    Figure 3-l. Programming Key Layout
    1
    A8
    A9
    A10
    All
    A12
    - Ad3
    - Al4
    - B6
    - 87
    - 88
    - 83
    - B2
    :
    3-2 
    						
    							IMl66-031System Programming
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    SYSTEM.COS PROGRAMMING PROCEDURE
    SYSTEM DEFAULTS
    All lines are DTMF
    Voice signalling attempted first when inter-
    com call is made
    1 sec. pause time
    2 sec. dial tone recall time
    30 sec. recall 
    from hold
    All lines 
    prfvate
    All lines are CO lines
    No toll restriction set
    Printer port set for 110 baud data rate
    2 sec. automatic pause insertion wait time
    PROCEDURE
    NOTE: Before performing this procedure, turnto the System COS Programming Reference
    Chart (Table 3-l), locatedat the end of this chap
    ter, and record all system COS requirements on
    it.1. Press 
    tTCM ++ 7 4 6 +K (base level entry)
    2.Select the PULSE/TONE or TONE ONLY dialing
    system default characteristics.l
    Press #. Dial tone will stop.l
    Press 0 to select TONE ONLY.ml
    Press 1 to sgct PULSE/TONE.l
    Press *. Dial tone will return.
    NOTE: In addition to setting the dialing mode,
    the above action defaults the system, line and
    station COS.3. Select Intercom 
    slgnalling first performed
    when intercom call is placed.l
    Press Al3 for tone signalling.
    -or-.
    Press Al4 for voice signalling.l Press 
    *.
    4.Select time interval for programmed pause.l
    Press 4. Dial tone will stop.l
    Press key to select time interval per
    chart. Tone burst confirms selection.l
    Press f. Dial tone will sound.
    5.Select pulse dial operatlng characteristics.l
    Press 5. Dial tone will stop.l
    Press keypad key to select operating
    characteristic per chart. Tone burst con-
    firms selection.
    \ KEYPULSES PER SECOND I BREAK/MAKE RATIO
    110 PPSI6W40
    220 PPS6W40
    0Press the % key. Dial tone will sound.
    6.Select flash/dial tone recall time interval.l
    Press 6. Dial tone will stop.l
    Press keypad key to select time interval
    .from chart.l
    Press *. Dial tone will sound.
    7.Select hold recall time interval.l
    Press 7. Dial tone will stop.l
    Press keypad key to select hold recall in-
    terval from chart.
    NOTE: The Q program selection makes It pos-
    sible for an exclusive hold condition, when set
    at a station, to place a line on a pennanent hold
    thaf cannot be released at any other station.
    :
    3-3 
    						
    							System Program-~~166-031
    8.l
    Press *. Dial tone will sound.
    Select 
    toll restriction table entries. Refer to
    programming table (Table 3-4) to preselect entry
    requirements.l
    Select table with memory key. The dial
    tone will stop when the selection is made.1 KEY 1 TABLE 1 KEY I TABLE 
    1Al Al
    1 1A5 A55 5
    A2 A22 2A6 A6
    6 6
    A3 A33 3A7 A7
    7 7
    A4 A44 4A8 A8
    8 8l
    Select mode of table with keypad key.
    Tone burst conforms selection.l
    Select entry line on table with memory
    key. Action clears any current entry and
    causes continuous busy tone to sound.l
    Dial number for entry line. Press % key
    to enter “match anything” digit. Tone
    burst sounds after each key is pressed.
    NOTE: An entry line can contain a maximum of
    16 digits.When the maximum number of digits
    are entered, the system sounds a fast 
    ringback
    tone, and steps to the next entrypoint on a table
    or to the next table.
    .*If less than sixteen digits are entered on
    line, select next entry location with
    memory key.l
    Repeat procedure for each desired toll
    restriction table.
    NOTE: Select an et&y line even if no input is re-
    quired.This action insures that any previous
    entry is cleared.Select a table and then select
    each line in the table to clear the table of 
    ail
    entries.
    Do not dial any numbers after the entry
    line selections.l Press 
    f.
    9.Program data speed baud rate for printer port.l
    Press 3 to set data speed of 300 baud.
    -or-
    *Press 0 to set data speed of 110 baud
    (defautt).l Press 
    *.
    10.When the system stores a dialed number for later
    redial, it automatically stores a pause each time
    the user waits a period of time between digits.
    (The length of the stored pause was programmed
    in step 4.) To program 
    length of time to wait be-
    tween’digits is inserted, proceed as follows:l
    Press ITCM +K 7 4 6 * to enter program-
    ming mode.l Press RECALL..
    l
    Press keypad key 1 to set wait time to
    750 milliseconds.
    -or-
    *Press keypad key 2 to set wait time to 2
    seconds.l Press 
    *.11. Press 
    MONtTOR to exit system COS program-
    ming mode..
    :
    3-4 
    						
    							IMI 66-031System Programming
    LINE COS PROGRAMMING PROCEDURE
    -
    -
    -
    -
    -
    LINE DEFAULTS
    All lines private
    All lines are CO lines
    No toll restriction Set
    Dialing mode is tone only
    300 
    msec. held call abandon time
    5.
    6.
    PROCEDURE
    NOTE: Before performing this procedure, turn
    fo the Line COS Programming Reference Chart
    (Table 
    3-2), located at the end of this chapter,
    and record all line COS requirements on it.
    7.
    1.Enter base level programming mode:lPress 
    ITCM +K 7 4 6 +K. The dial tone8.
    will sound.Press keypad key to restore after hold is aban-
    doned.
    KEYTIME INTERVAL
    8
    60 MSEC.
    9300 MSEC. (MFAULT)
    Repeat procedure from step 3 for next fine to be
    programmed.
    2.Choose privacy status of each line.NOTE: There are a maxlmum of six lines to bel
    Press 8. Dial tone will stop. This actionprogrammed on a model 0616X system and a
    initializes all lines as private. This condi-maximum of eight lines on an 0816X system-
    tion is also system default value.9.lPress line select key of each line whichPress& MONtTOR to exit line COS programming.
    is to be non-private.Dial tone will sound. Press memory 
    keys to assign toll restriction
    tables to 
    Ilne.
    KEYTABLEKEYTABLE .
    Al
    1A66
    A2
    2A66
    A33A77
    A44A88
    Specify dialing mode per chart with keypad key.
    A tone burst will confinn selection.
    -A tone burst sounds after each selection
    for confirmation.l
    Press %. Dial tone will sound.
    3. Press tine select key (program keys Bl-B6 for
    model 0616X or Bl -B8 for model 0816X) for line
    to be programmed. Dial tone will stop.
    NOTE: Selecting a line forprogramming clears
    all assigned toll restriction tables.
    4.Specify line type per chart with keypad key. Atone
    burst will confirm selection.
    3-5 
    						
    							IMI 66-031
    STATION COS PROGRAMMING PROCEDURE
    System Programming
    STATION DEFAULTS
    r No ringing line preference enabled
    - No prime line is chosen
    - DSS/BLF port is disabled
    -PA port is disabled
    - No delayed ringing enabled
    - No access denied
    - No orfgination denied
    - No privacy released
    -Day and night ringing patterns set as follows:
    - station 10, 17, and 24 all lines
    - System-wide, all call paging in zone D
    -tine select keys 1 -n selects lines 1 -n(squared pairing)
    PROCEDURE
    NOTE: Before peffotming this procedure, turnto the Station COS Programming Reference
    Chart (Table 3-3), located at the end of this chap-
    ter, and record ail station COS requirements on
    it.
    1.Enter the base programming mode:l
    Press ITCM +# 7 4 6 +#. Dial tone will
    sound.
    2.Press a two-key sequence on keypad to choose
    station port for programming (i. 
    e.,to choose sta-
    tion 11 press 11). Tone burst sounds to confirm
    selection. Improper selection results in dial tone.
    NOTE: Station port selection defaults the foi-
    lowing features: 
    DSS/BLFport enable, ,PA port
    enable, prime line selection, and ringing line
    preference enable. Pius, toil restriction table
    assignments are disabled.
    3.Configure port as DSS/BLF console port (if con-
    sole port is required)..
    Press RECALL. Tone burst sounds to
    confirm selection.l
    Skip this step if DSS/BLF console is not
    installed at station port currently being
    programmed.l
    If enabled, do not proceed beyond this
    step unless port is also to be
    programmed as PA port.
    4.Configure port as PA port (if PA port is desired).
    *Press 9. Tone burst confirms selection.
    :
    aSkip this step if PA port is not desired.l
    Do not proceed beyond this step if PA
    port selection 
    is made.5. Choose prime line or prime 
    fntercom. Tone
    burst confirms selection.l
    Press tine select key for line desired.
    -or-* Press 
    ITCM.NOTE: if more than one iine selection key is
    pressed, the last one pressed selects the 
    ac-
    cep ted prime line.
    6. Enable ringing line preference.l Press 1.
    7. Press memory keys to assign toll restriction
    tables 
    to station.l
    At this point, there are no toll restriction
    tables assigned.l
    Tone burst confirms each selection.
    Skip to step 16 after programming the toll restric-
    tion table assignments unless other station COS
    programming 
    must be performed.l
    Durfng initial programming of a station, it
    is recommended that programming steps
    8-14 be performed in the order that they
    are presented below. In steps 8-14, the
    defautt condition is automatically set
    whenever the program selection key is
    pressed. This default value is overridden
    by the subsequent programming action.l
    During subsequent reprogramming of a
    station, any step, controlling a feature
    that does not need to be reprogrammed,
    can be skipped over thus leaving the cur-
    rent COS condition intact. 
    It is not neces-
    sary to return to the base programming
    mode to shift from one programming step
    to another except when performing step
    15. Program step 15, which sets the line
    appearance to key assignment, must be
    followed by a return to base level
    programming (press 
    *).
    8. Program direct ringing assignments.NOTE: A 
    line may be programmed for direct
    ringing or delayed ringing but not for both ring-
    3-6 
    						
    							IMI 66-031System Programming
    trig features. If dtrect rtngtng Is setected after
    delayed rtngtng Is selected, delayed rtngtng wttt
    be disabled.
    Press 2 for direct tinging. Tone burst
    sounds to confirm.
    DefauQ condition of no ringing enabled
    now set on all iines.
    Press line select 
    key (program keys Bl-
    B6 for 0616X and Bl -B8 for 0816X) for
    each line on which direct ringing is
    desired. Tone sounds after each selec-
    tion.
    9. Program 
    delayed ringing assignments.l
    Press 3 for delayed tinging. Tone burst
    sounds to confirm.l
    Press Iine select key (program keys Bl-
    B6 for 0616X and Bl -B8 for 0816X) for
    each line on which delayed 
    n’nging is
    desired.l
    Tone sounds after each selection. Delay
    time is 15 seconds.
    10. Choose 
    access denled status.
    0Press 4. Tone burst sounds. Defauft
    condition of access not denied set on all
    lines.l
    Press line select key (program keys Bl-
    B6 for 0616X and Bl -B8 for 0816X) for
    each line on which access is to be
    denied.l
    Tone burst sounds after each selection.
    11.Program 
    call origination denled status.l
    Press 5. Tone burst sounds. Default
    condition of call origination not denied set
    on all lines.l
    Press line select key (program keys Bl-
    B6 for 0616X and Bl -B8 for 0816X) for
    each line on which call origination is to
    be denied. Tone burst sounds after each
    selection.
    12.Set access to privacy release.l
    Press 6. Tone burst sounds. Defauit
    condition of no access to privacy release
    set on all lines.l
    Press line select key (program keys Bl-
    B6 for 0616X and Bl -B8 for 0816X) for
    each line on which access is to be
    denied. Tone burst sounds after each
    selection.13. Set night ringing status.
    l
    Press 8. Tone burst sounds. Defauit con-
    dition of no night ringing will be set on all
    lines.
    ePress line select key (program keys Bl-
    B6 for 0616X and Bl -B8 for 0816X) for
    each line on which night ringing is
    desired. Tone burst sounds after each
    selection.
    14. Set all-call and zone paglng capability. Default
    value is all-call at all stations in system.l
    Press 1. Tone burst sounds. Clears sta-
    tion from paging zones A, B, and C.l
    Press ITCM to clear station from atl-catl
    (if required).l
    To assign reception by zone,l
    Press line select key 1 (Bl) for zone Al
    Press tine select key 2 (B2) for zone Bl
    Press line select key 3 (B3).for zone C.l
    Press line select key 4 (84) for all-call (if
    it was previously cleared).l
    To enable origination by zone,l
    Press line select key 5 (B5) for zone A.
    Press line select key 6 (B6) for zone Bl
    Press line select key 7 (B7) for zone Cl
    Press line select key 8 (B8) for all-call (if
    it was previously cleared).
    NOTE:Step ldmustbe tmmedtapty fottowedby
    a 
    return to bass level.
    15. Set llne appearance to key assignment if cur-
    rent settings are not correct. System default con-
    figures 
    line appearance to key assignment so that
    line assignments are squared. A squared assigri-ment has tines l-6 assigned to keys Bl-B6 for
    model 0616X, and lines l-8 assigned to keys Bl-
    B8 for model 816X.l
    To re-assign line/key configuration,l
    Press 7. Tone burst sounds.l
    Press Gne key (Bl-88). Tone burst
    sounds.l
    Press keypad key for number of line (l-
    6). Tone burst sounds.l
    Press next line key and keypad key com-
    bination. Repeat for each line. All iine
    select keys can be programmed to select
    same tine if such a condition is desired.l
    To disable line select key and indicator
    tight for any 
    lines which are unassigned
    to a particular station,l
    Press line select key for unassigned line.l Press 9.
    l
    Repeat for each unassigned line.
    16.Press 
    % to return to base programming mode.
    17.Repeat steps 1 through 16 for each station con-
    nected to the system.
    18. Press MONITOR to exit programming 
    mode. 
    						
    All Comdial manuals Comments (0)