Home > Comdial > Communications System > Comdial Executech Model 0616x, 0816x Electronic Key Systems Instructions Manual

Comdial Executech Model 0616x, 0816x Electronic Key Systems Instructions Manual

Here you can view all the pages of manual Comdial Executech Model 0616x, 0816x Electronic Key Systems Instructions Manual. The Comdial manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 1

COMCHAL
ExecuTech
Model 0616X & 0816XElectronic Key Systems
This manual applicable for the following key system models:l 0616X Manufacturing Code 
8xxC and Later
* 0816X All Ma~uf&cturing Codes1.1J
IMI 66-031.043/89 

Page 2

IMI 66-031Table of Contents
TABLE OF CONTENTS
CHAPl-ERt INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . .;‘:
MANUAL SCOPERELATEDPUBLICATioN’S . . . . . . . . . . . . . . . . . .. . . . . . -
fNSTALLEWUSER INFORMATIONREGARDING FCC RULES AND ‘REGULATIONS . . . . . . . . . . . . . . . . . l-l
CHAPTER 2 INSTALLATION0 . m . . . . 0 . . . . . . . .2-l
MOUNTtNGCONSIDERATldNS l : l . ‘. * . l : : : . . . . . . . . . . . . . . .2-lMOUNTING PROCEDURE . . . . . . . . . . . . . . . . . . . . . . ....

Page 3

lMl66-031Introduction
CHAPTER 1
INTRODUCTION
MANUAL SCOPE
This publication contains installation, programming,
and maintenance information for the following 
Execu-Tech electronic key systems and the associated
telephone equipment.l
Model 0616X - manufacturing code 8xxCand
laterl
Model 0816X - all manufacturing codes
This system is fully protected, and therefore the instal-
lation does not require the services of an authorized
agent. However, the installation procedures detailed in
this manual should...

Page 4

IntroductionIM! 66-031
Disconnect all equipment not owned by the telephone
company.If this corrects the problem, the faulty equip-
ment must not be reconnected to the telephone line untilthe problem has been corrected. Any 
trouble that
causes improper operation of the telephone network
may require the telephone company to discontinue ser-
vice to the trouble site after they notify the user of the
reason.
REPAIR 
AUTHORIZATION
FCC regulations do not permit repairof customer owned
equipment by anyone...

Page 5

IMI 66-031installation
CHAPTER 2
INSTALLATION
MOUNTING 
CONSIDERATIONS
l
The KSU should be attached vertically to any stur-
dy, flat, surface. It may be vertically rack mounted
if desired.

l
The KSU must be located within six (6) feet of a
proper electrical outlet. The power supply requires
a dedicated 
117VAC  .15 AMP circuit, with a third-
wire ground, supplied to a standard (NEMA 
515R)
electrical outlet.
 l 
The distance between the KSU and the
TELCO/PBX  jacks must be 25 feet or less as per
FCC...

Page 6

InstallationIMI 66-031
II
I
0-
I-t-
19.22 INCHES
1l----sk~
0----o--
lI
Figure 2-1. Mounting DimenSlOnS
SYSTEM WIRING
System cabling may be routed concealed or visible as
the installation location requires, Good engineering
practices must be observed 
and all applicable building
codes must be adhered to.
Table 2-l and Figures 2-2
through 2-4 illustrate the system wiring and connection
points for the key system.
AC Power Connection
The AC power is applied to the system by connectingthe AC power cord to the...

Page 7

IMI 66-031Installation
jacks, it is a good practice to connect them to earth
ground.Doing this may help prevent them from induc-
ing radio frequency and/or AC interference into the 
SYS-tern
The polarity between the individual wires in a par-
ticular voice or data pair is not critical; however do
not connect the voice circuits to the data 
CirCuits.
Cable CIipsEach cabinet-mounted 
50-pin male connector is
equipped with a retaining clip. This clip is designed to
secure the matted connection once it is...

Page 8

InstallationIMl66-@31
Wire the KSU TD (data to device from KSU) pin to
the device RD (receive data) pin.
Wire the KSU SG (signal ground) pin to the device
SG (signal ground) pin.Wire the KSU CTS (clear-to-send status from
device to KSU) pin to the device FITS (request-to-
send) output pin.
NOTE: The KSUrequires a positive voltage, wtth
respect to signal ground, in order to send data.If required, wire the KSU 
FITS (request-to-sendstatus signal from the KSU to the device) pin to the
device DSR...

Page 9

IMI 66-031Installation
Area 
Paging Interface - Station PA Port
A station port can be configured by class of service
programming to be a PA port. As a PA port, it can be
used to couple a station voice path to an external device
(see Chapter 3 for programming details).
The audio input of an external paging amplifier can
be connected to the audio pair of the station port as
illustrated in Figure 2-3.
The audio input connection must be isolated with a
600 ohm to 600 ohm audio matching transformer.
Terminate...

Page 10

InstallationMI 66-031l----1CLIP TERM.
-I-OUTPUT AS
LOW24V@ 0.4A MAXREOUIRED BY
RELAY COILVpOokZESUPPLY
AC-- 
-VOLTAGE CLAMPING DIODE
RECOMMENDED
v ;g :bXlNPUt.
SIGNALLING0
0
Flgure 2-2. External Signalling-Typical Connection.
600~ TO SOOn( 1:1)AUDIO
TRANSFORMi%TO KSU STATION
PORT 23 OR 25 IF
ENABLE IS REQUIRED
OR TO ANY UNUSED
STATION PORT IF
ENABLE IS
NOT REQUIRED.
uus
62OnA SYSTEM
-0AUDIO INPUT
4
ENABLE INPUTQQ
TO KSU EXTERNAL CONTROL CONNECTION 
POlNTSON 
66WXX CONNECTOR BLOCK.
l CLIPS 45 & 46 FOR...
Start reading Comdial Executech Model 0616x, 0816x Electronic Key Systems Instructions Manual

Related Manuals for Comdial Executech Model 0616x, 0816x Electronic Key Systems Instructions Manual

All Comdial manuals