COMCHAL ExecuTech Model 0616X & 0816XElectronic Key Systems This manual applicable for the following key system models:l 0616X Manufacturing Code 8xxC and Later * 0816X All Ma~uf&cturing Codes1.1J IMI 66-031.043/89
Page 2
IMI 66-031Table of Contents TABLE OF CONTENTS CHAPl-ERt INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . .;‘: MANUAL SCOPERELATEDPUBLICATioN’S . . . . . . . . . . . . . . . . . .. . . . . . - fNSTALLEWUSER INFORMATIONREGARDING FCC RULES AND ‘REGULATIONS . . . . . . . . . . . . . . . . . l-l CHAPTER 2 INSTALLATION0 . m . . . . 0 . . . . . . . .2-l MOUNTtNGCONSIDERATldNS l : l . ‘. * . l : : : . . . . . . . . . . . . . . .2-lMOUNTING PROCEDURE . . . . . . . . . . . . . . . . . . . . . . ....
Page 3
lMl66-031Introduction CHAPTER 1 INTRODUCTION MANUAL SCOPE This publication contains installation, programming, and maintenance information for the following Execu-Tech electronic key systems and the associated telephone equipment.l Model 0616X - manufacturing code 8xxCand laterl Model 0816X - all manufacturing codes This system is fully protected, and therefore the instal- lation does not require the services of an authorized agent. However, the installation procedures detailed in this manual should...
Page 4
IntroductionIM! 66-031 Disconnect all equipment not owned by the telephone company.If this corrects the problem, the faulty equip- ment must not be reconnected to the telephone line untilthe problem has been corrected. Any trouble that causes improper operation of the telephone network may require the telephone company to discontinue ser- vice to the trouble site after they notify the user of the reason. REPAIR AUTHORIZATION FCC regulations do not permit repairof customer owned equipment by anyone...
Page 5
IMI 66-031installation CHAPTER 2 INSTALLATION MOUNTING CONSIDERATIONS l The KSU should be attached vertically to any stur- dy, flat, surface. It may be vertically rack mounted if desired. l The KSU must be located within six (6) feet of a proper electrical outlet. The power supply requires a dedicated 117VAC .15 AMP circuit, with a third- wire ground, supplied to a standard (NEMA 515R) electrical outlet. l The distance between the KSU and the TELCO/PBX jacks must be 25 feet or less as per FCC...
Page 6
InstallationIMI 66-031 II I 0- I-t- 19.22 INCHES 1l----sk~ 0----o-- lI Figure 2-1. Mounting DimenSlOnS SYSTEM WIRING System cabling may be routed concealed or visible as the installation location requires, Good engineering practices must be observed and all applicable building codes must be adhered to. Table 2-l and Figures 2-2 through 2-4 illustrate the system wiring and connection points for the key system. AC Power Connection The AC power is applied to the system by connectingthe AC power cord to the...
Page 7
IMI 66-031Installation jacks, it is a good practice to connect them to earth ground.Doing this may help prevent them from induc- ing radio frequency and/or AC interference into the SYS-tern The polarity between the individual wires in a par- ticular voice or data pair is not critical; however do not connect the voice circuits to the data CirCuits. Cable CIipsEach cabinet-mounted 50-pin male connector is equipped with a retaining clip. This clip is designed to secure the matted connection once it is...
Page 8
InstallationIMl66-@31 Wire the KSU TD (data to device from KSU) pin to the device RD (receive data) pin. Wire the KSU SG (signal ground) pin to the device SG (signal ground) pin.Wire the KSU CTS (clear-to-send status from device to KSU) pin to the device FITS (request-to- send) output pin. NOTE: The KSUrequires a positive voltage, wtth respect to signal ground, in order to send data.If required, wire the KSU FITS (request-to-sendstatus signal from the KSU to the device) pin to the device DSR...
Page 9
IMI 66-031Installation Area Paging Interface - Station PA Port A station port can be configured by class of service programming to be a PA port. As a PA port, it can be used to couple a station voice path to an external device (see Chapter 3 for programming details). The audio input of an external paging amplifier can be connected to the audio pair of the station port as illustrated in Figure 2-3. The audio input connection must be isolated with a 600 ohm to 600 ohm audio matching transformer. Terminate...
Page 10
InstallationMI 66-031l----1CLIP TERM. -I-OUTPUT AS LOW24V@ 0.4A MAXREOUIRED BY RELAY COILVpOokZESUPPLY AC-- -VOLTAGE CLAMPING DIODE RECOMMENDED v ;g :bXlNPUt. SIGNALLING0 0 Flgure 2-2. External Signalling-Typical Connection. 600~ TO SOOn( 1:1)AUDIO TRANSFORMi%TO KSU STATION PORT 23 OR 25 IF ENABLE IS REQUIRED OR TO ANY UNUSED STATION PORT IF ENABLE IS NOT REQUIRED. uus 62OnA SYSTEM -0AUDIO INPUT 4 ENABLE INPUTQQ TO KSU EXTERNAL CONTROL CONNECTION POlNTSON 66WXX CONNECTOR BLOCK. l CLIPS 45 & 46 FOR...