IMI 66-031System Programming
SMDR ANP COS PRINTOUT
SMDR PRINTOUT
A data printer can be connected to the system to be
used for printing station message detail recording
(SMDR) information. The SMDR data is provided
automatically as it is generated. No intervention is
required to obtain the printout. The data is for-
matted as shown in Figure 3-2. Either an 80
column or a 
40-column printout line can be
selected through the system COS programming.
COS PRINTOUT
When a data printer is connected to the system...

Page 22

STATION NUMBER
40 COLUMN
PRINTOUT
LINES
1T [CARRIAGE RETURN! (LlNEj
2X &ARRlAGE FE~URN 1 I--,I-
MONTH/DAY/YEARINITIATE TIME-HOUR : MINUTE
(24 HOUR REAL TIME CLOCK)
\J
DIALED DIGITS-UP TO MAXIMUM OF 32
(ACCOUNT CODES ARE ISOLATED BY l OR # SYMBOLS
NOTES
1. CARRIAGE RETURN AND LINE FEED IMMEDIATELY
;O$.OW LAST PRINTED CHARACTER ON EACH
9782200
OUTGOING CALL24 2 
12/05/06 17:Ol.5
(WITH ACCOUNT CODES)1~~33456789’0#‘7412580#9831’w
AC POWER FAILURE AND
RESTORATION
2FFTlME l * 12/05/8617:03.;. 12/05/06 17:08...

Page 23

IMi 66-031System Programming
SYSTEM COSTOLL RESTRICTION TABLES
PAUSE TIRE2.0 SECPULSE DIAL 20 PPS
FLASH TIME720 MSECHOLD RECALL 240 SEC
TABLE1DENY11
2 0
3 
-4
LINE 
COSLINE PRV TYPE PU- HOLD TOLL
RLSLSE.SOMS TABLESTABLE 2 ALLOW
1 17034344664
2 17039493113
3 1985
4 1831
1C.O.2C.O.3C.O.4 xc-0.5 x
AUX
6NONE7PABX x
8 XPABX x
STATION 13
TOLL RESTRICTION
P.A. ENABLE
PRIME 
LINE123 6
123 6
123 6
123 6
78X
456X456
123
1
LINE12345678
RING X
DELAY RING X
NITE RING
ACCESS DENY
ORIGIN DENYPRIVACY 
RLS
ALL CALL...

Page 24

IMI 66-031System Programming
SYSTEM CLOCK INFORMATION
SElTlNG THE CLOCK
1.Press ITCM, then dial +# #.
2.Dial clock date with keypad keys.l
Values less than 10 must be dialed asox.
l
Hours must be expressed in 24-hour for-
mat..
Enter: YEAR MONTH DAY HOURMINUTE
Example: 8808061530 (August 6,1988,3:30 PM)
3.If SMDR printer is installed and operating, clock
date will be printed as illustrated in following typi-
cal example:
W 01/08/86 16:00
4.Reset minutes setting, if necessary, as follows:l
Repeat step...

Page 25

IMI 66-031
SYSTEM SPEED DIAL PROGRAMMING
System Programming
Ten (10) system speed dial numbers can be stored
from station 10 for use at all stations in the system.
To store speed dial numbers,To end procedure,l Press MONITOR
l Press 
ITCMt. .
l
Perform the following steps:l Press SAVE.
l
Dial storage location (1-O) from keypad.
Press line select key (program keys 
Bl-S6)l
SYSTEM SPEED DIAL INDEX
(enter programmed numbers)
1
2
to identify line to be preselected during opera-3
tion (otherwise system will...

Page 26

IMI66-031System Programming
Table 
3-l. System COS Programming Reference
PROCEDURE
Note: Circle the record values at right
before performing the procedure given below.
1. BASE LEVEL ENTRY.PressfTCM*746+
2PULSWONE OR TONE ONLY DIALING MODE. Presst.
Press 0 for tone dialing.Press 
1% pulse/tone dialing
.
Press*
3.FIRST ATEMPTED INTERCOM SIGNALING MODEPress Al3 for tone signalling .
.Press Al4 for voice signalling
.Press*
4. TIME MERVAL FOR PROGRAMMED PAUSE.Press4
.Press one key
KEY 1 1 1 2 1 3 1 4 1 5 1 6...

Page 27

1MI 66-031System Programming
0. TOLL RESTRICTION RtQlhMtNTS.
Set system toll restriction requirements per instructions
given on Table 3-4Record 
all toll restricbn data on table 3-4.
9. SMDR DATA SPEED BAUD RATE. 
Press3=3oDbaud.
Press OZlO baudI. Press1 
=7!5Omsec..
Press ,fl-2 sec.
No&: If a timeout occurs during the program-
ming sequence, 
perform base level entry again
and proceed at any program step. 

Page 28

IMI 66-031System Programming
Table 3-2. 
Line COS Programmlng Reference
PROCEDURE
NUltEnter the information In the box at right before
performing the pfugram pfucadwes givan below
1. BASE LEVELENTRY.Press ITCM * 746 S2 PRNACY STATLJS.
Press 6. All line6 private.
Press keys for non-private..(Bl-86 for model 0616x). (B1-86formodelO616X). Press*
3. SELECT LINE FOR PROGRAMMING.
Press 81-88 (model 0816X).
Press BTi6 (model 0616X)4. SPECIFY LINE TYPE. 
Pressby: O=Disabledl.he
1 = Auxiliary Line
2=COtine...

Page 29

IMI 66-031System Programming
Table 3-3. Statlon COS Programming Reference
(Copy 
this sheet as required)
PROCEDURE
Circle or enter the record v&es st right before
RECORD
Enter lnfotmstion or circle desin?d veh8 below before
2. 
DlALTWO-DIGITPORT NUMBER
. Press RECALLINTERCOM NUMBER
4. CONFIGUF& PA PORT (opti
[(06,6X)!, 12 (3 14 15 16 I~~M~ji&j$jj~. . . . _ ..:..:c...: ::. . . . . . . . . . . . .
ressBl-B6(model D616X). Press4
(0816X) 
11 /2 13 (4 15 16 17 1. Press6
.
Press Bl-B6 (model D616X).
Press By-&...

Page 30

IMI 66-031System Programming
Table 3-3, STATION COS PROGRAMMING REP ERENCE (Continued)
(Copy this sheet as required)
PROCEDURE
circle or enter therecordvalues at right
14. ALL 
CALLAND ZONE PAGING
.Press # lTCM to clear allcall..
Press keys: Bl-B4 = receive A. B, C, and all-call.
Press keys: BS-B8 = originate A. B. C and allcall
0 Dial l-6 (0616X)
. Dial 
147&16X)
usedkeyand light. Press*
17. PROGRAM NEXT 
STATlON.Repeat procedure from step 218. END 
P&&AMMING.Press MONITOR
NO7E If a timeout occurs...