TABLE OF CONTENTS Chapter 1 introduction.............................................l-l MenualScupe........................................................1.1 Related information.....................................................1.1 StatlonTypes........................................................i.i InatallerNaer lnformatlon Regarding FCC Rules And Ragulatlona...........................l-2 Chapter 2 lnstallatlon...............;..............................2-1 Mounting...
Page 3
IMI 66-074 Line COS Programmlng Reference Table.........................................3.10 Statlon Coo Programming.......,.........................................3-11 StationDefaults.............................................................3-11Procdum................................................................ -11 Statlon COS Programming Reference Tablec3.......................................3-l COS And SMDR Printout..................................................3.18 Caeaette Tape Record Of...
Page 4
CHAPTER 1INTRODUCTION MANUAL SCOPE This publication contains installation, programming, and maintenance information for the Model 1432 KSU electronic key system and associated electronic key telephone stations. NOTE: This manual is applicable for model 14328 KSU Rev F and later. This key system is fully protected, and therefore the installation does not require the services of an authorized agent. However, the installation procedures detailed in this manual should only be performed by individuals...
Page 5
inrroauctronIMI 66-074 INSTALLER/USER INFORMATION REGARDING FCC RULES AND REGULATIONS This electronic key system complies with Federal Communications Commission (FCC) Rules, Part 68. The FCC registration label on the KSU contains the FCC registration number, the ringer equivalence number, the model number, and the serial number or production date of the system. NOTlFlCATlON TO TELEPHONE COMPANY Unless a telephone operating company provides and installs the system, the telephone operating company which...
Page 6
CHAPTER 2INSTALLATION MOUNTING CONSIDERATIONS The KSU cabinet should be attached vertically to any sturdy, flat, surface. It may be vertically rack mounted if desired. The KSU must be located within six (6) feet of a proper electricaloutlet. The KSU power supply requires a dedicated 117VAC 15 AMP circuit, with a third-wire ground, supplied to a standard (NEMA 5-l 5R) electrical outlet. The distance between the KSU and the TELCWPBX jacks must be 25 feet or less as per FCC requirements. A nominal distance...
Page 7
CABINET OUTLINE 24%iPPROX)MOUNTING HOLE LOCATIONS . . + I-L4 (APPROX) (ALL DIMENSIONS IN INCHES) Figure 2-1. KSU Mountlng DimensionsSYSTEM WIRI’::LINE CONNECTIONS System cabling may be routed car (?d or visible as the installation location requires. ( : j engineering practices must be observed and a : ;- licable building codes must be adhered to. Tables _ : through 2-5 and Figures 2-2 through 2-5 illustrate the system wiring and connection points.AC POWER CONNECTION Employ a dedicated 11 NAC 15 AMP...
Page 8
some protectlon to the commonequipment, It should not be relied upon for total protection. To help ensure that external overvottage surges do not damage the system, lt Is recommended that gas discharge tubes, or slmllar primary protectlon devices, be Installed, and properly grounded, In all connected TELCO Ilnes.STATION CONNECTIONS Connections between the KSU and the stations are typically via type 66M-xx connector blocks which are cable connected to the KSU 50-pin male connector. The maximum...
Page 9
11 latallarlonIMI 66-074 l Connect a keyset to the first data-paired port. l Connect the DB32S Adjunct Feature Module to the voice pair and data pair of the second data-paired port. lFor the feature to be enabled, the port to which the Adjund Feature Module is connected must be programmed as a DSS console with call announce. SECURE OFF-HOOK VOICE ANNOUNCE TELEPHONE CONNECTIONS This telephone system supports the Secure Off-Hook Voice Announce (SOHVA) feature provided by certain keyset models. Two...
Page 10
SYSTEM GROUNDINGThe wmmon equipment cabinet has internal secondary surge protection on all line ports. In order for this protection to be effective, the cabinet MUST be connected to a reliable earth ground such as a metal wld water pipe or a building frame ground. The grounding wire must be of #lO or #12 insulated, solid copper and separate from the three-wire AC line cord. A ground stud is located on the wmmon equipment cabinet for this purpose.COMMON AUDIBLE AND AUXILIARY STATION INTERFACE Two sets...