Comdial Dxp Plus Instructions Manual
Here you can view all the pages of manual Comdial Dxp Plus Instructions Manual. The Comdial manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 651
2.4 Checking Signal Paths To verify correct signal paths between the server and the system, use the following illustration to locate the signal paths and check them using an ohmmeter. Be sure that the RD, TD, RTS, and CTS signals from the server connect to the appropriate signals at the system serial data port as detailed in this table. Server Signal ConnectionsSystem Signal Connections 9-Pin Serial Connector25-Pin Serial Connector Modular Serial Data Connector RDPin 2RD Pin 3 TD Pin 4 TDPin 3TD Pin 2 RD...
Page 652
2.5 Programming The DXP and DXP Plus System You can change the baud rates, data bits, stop bits, parity, and flow control for each serial data port in the system to match the data device that you connect there. Select a serial port and set the parameters shown in the following table. Baud OutBaud InData BitsStop BitsParityFlow Control 96009600 8 1 NONE RTS/CTS Once you enter the DXP or DXP Plusprogramming mode, perform the following steps; 1. Press CONTROL T for main menu. 2. From main menu, select...
Page 653
3.0 Administering The Data Link From Server To System This section covers system administration issues, including the opening and closing of the Telephony Services data link, and using the system driver/interface. 3.1 Using Administration Options From the DXP Administration portion of the main menu, the following options exist: 1. About... 2. Active Session Information 3. DXP Link Administration 4. Select Active Serial Port 3.1.1 Using The About... Menu To Access Software Version Information Selecting...
Page 654
3.1.3 Using The Link Administration Menu Options Selecting the Link Administration menu option provides additional options as follows: 1. Clear Port Statistics 2. Close DXP Link 3. Edit Port Configuration 4. Open DXP Link The first line of the option screen shows the active serial port (example, “Board:0 Port:0). 3.1.3.1 Clearing Port Statistics Selecting this option resets all of the monitored items on the “Link Statistics Screen” such as busy hour, busy minute, and packets received. 3.1.3.2 Closing A...
Page 655
4.0 Trouble shooting The Interface Option Problem Possible Cause Unable to load Comdial NLM 1. Telephony Service’s software not installed correctly. 2. Telephony Service’s network loadable module (NLM) not loaded. The COMDIAL.NCF file on the supplied diskette shows the loading order of all required NLM’s Cannot establish DXP link 1. Line cord between server and DXP not connected or loose connection in house wiring, if used. 2. Software key incorrect or not installed. 3. DB-9 to DB-25 adapter does not...
Page 656
Installing And Programming The Analog Terminal Interface On The Digital Communications System 1.0 Introducing The Analog Terminal Interface This publication describes the features, applications, installation, and specifications of the Comdial Analog Telephone Interface (ATI-D-1PT). The ATI-D-1PT is a multipurpose,on-premiseaccessory for the digital communications system. It provides the following features: ·INDUSTRY-STANDARD TELEPHONE (IST) INTERFACE -This feature adapts most industry-standard telephone...
Page 657
1.1 Detailing The Specifications Electrical Specifications Power requirements: Supplied by the common equipment Ringing voltage: 55 VAC Nominal @ 20 Hz (45 VAC minimum) Power rated to maximum REN = 2.0 Battery feed voltage: 24 VDC nominal Loop current limits between ATI-D and IST interface: 20 ma min. at 620 ohms 70 ma max. at 0 ohms DC loop limits from ATI-D to industry standard interface per port: 620 ohms maximum including interfaced telephony device (Approximately 4000 feet with #26 AWG twisted-pair...
Page 658
Environmental Specifications Operating temperature: 32-122 F (0-50 C) Humidity: 90 % relative, non-condensing Mechanical Specifications Height: 2.375 inches Width: 8.062 inches Length: 11.125 inches Weight: 4 lbs. (plus 2 lbs. for packing material) Industry/Regulatory Standards FCC registered and listed for safety compliance as part of digital communications system FCC certified, Part 15 (class A) Installing And Programming For ATI–D–1PT IMI89–208 Installing The ATI–D–1PT – 3
Page 659
2.0 Installing The Analog Terminal Interface 2.1 Detailing The Mounting Considerations 1. The ATI-D-1PT can be attached to any sturdy, flat surface. 2. The distance between the ATI-D-1PT and the common equipment must be 25 feet or less. 3. The mounting location must be secure and dry and have adequate ventilation. The temperature range of the location must be within 32-122° F (0-50° C). 4. If the mounting surface is damp or if it is concrete or masonry material, a backboard must be attached to it before...
Page 660
Outline Dimensions (In Inches)Spacing For Mounting Hardware (In Inches) AW139 Detailing The ATI–D–1PT Dimensions Installing And Programming For ATI–D–1PT IMI89–208 Installing The ATI–D–1PT – 5