Page 241
1-33 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies Figure 1-22 Installing the Power Supply in the Chassis Step 6 Determine whether you will be routing the source DC cables on the left- or right-side of the power supply. Loosen and remove the two screws securing the top half of the fixed cable guide on the side you will be routing the source DC cables. Remove the top half of the cable...
Page 242
1-34 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies Step 8Connect the source DC cable lugs to the 2700 W power supply terminal block posts (Figure 1-23) in this order: Ground cable lug to the ground terminal posts Negative (–) source DC cable lug to terminal post –VE-1 Positive (+) source DC cable lug to terminal post +VE-1 NoteIf you are only going to install one pair of source DC cables...
Page 243
1-35 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies Figure 1-24 Securing the Cables to the Cable Guides Step 11 Install the detached source DC cable guide that is supplied with the power supply (see Figure 1-25): a.Position the thicker half of the cable guide under the two or four source DC cables and align the cables with the grooves in the cable guide. The cable guide should be placed...
Page 244
1-36 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies Step 12Remove the warning flags and cautionary tape from the source DC mains and switch the source DC on. Step 13Verify the power supply operation by checking that the power supply front panel LEDs are in the following states: INPUT 1 OK LED—If you have source DC cables attached to the VE-1 pair of power supply inputs, verify that the...
Page 245
1-37 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies Figure 1-26 4000-W DC-Input Power Supply Installation Features Required Tools The following tools are required for the power supply removal and installation procedures: Number 2 Phillips-head screwdriver 1/4-inch open-ended wrench or 1/4-inch nutdriver Wire cutters to cut the cable tie-wraps Additional tools might be necessary to install...
Page 246
1-38 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies Removing a 4000 W DC-Input Power Supply WarningWhen installing the unit, always make the ground connection first and disconnect it last. Statement 42 WarningBefore performing any of the following procedures, ensure that power is removed from the DC circuits. To ensure that all power is removed, locate the circuit breakers or fuses on the...
Page 247
1-39 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies Step 7Loosen the captive installation screw on the power supply. (See Figure 1-27.) CautionUse both hands to install and remove power supplies. The 4000 W DC-input power supply weighs 32 pounds (14.5 kg). Step 8Grasp the power supply handle with one hand, and slide the power supply part of the way out of the chassis. Place your other...
Page 248
1-40 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies Figure 1-28 Handling a 4000 W DC-Input Power Supply Step 9 If the power supply bay is to remain empty, install a blank power supply filler plate (Cisco part number 700-03104-01) over the opening, and secure it with the captive installation screw. Installing a 4000 W DC-Input Power Supply The 4000 W DC-input power supply can be wired for...
Page 249
1-41 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies When installing a 4000 W DC-input power supply, observe the following guidelines: For proper 4000 W DC-input redundant power configuration, all source DC cables for one 4000 W DC-input power supply must come from the same battery system (A feed), and all source DC cables for the second 4000 W DC-input power supply must come from a...
Page 250
1-42 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies Installing the 4000 W Power Supply (Wiring for 2700 W Operation; Left Power Bay) Refer to Figure 1-26 for item location and identification on the 4000 W DC-input power supply. NoteYou should allow a minimum of 2.5 to 3 inches (63.5 mm to 76.2 mm) of space between the side of the power supply and any obstructions (such as the side of an...