D-36Mirage WU-L User Manual020-100774-01 Rev. 2 4-2012 Appendix D: Serial Command Reference (LBL) LEFT BLANKING CONTROL GROUP: Input SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Set the number of lines to blank (turn to black) at the left of the image. This can be used to blank out any unwanted data near the left edge of the image. A positive amount of blanking makes the image smaller. A negative amount of blanking makes the image larger. Negative blanking is only applicable...
Page 202
Appendix D: Serial Command Reference Mirage WU-L User ManualD-37020-100774-01 Rev. 2 (4/2012) (LDV) LEVEL DETECTOR VALUE CONTROL GROUP: Unsaved SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION The Level Value control specifies the value to be used by the level detector. The range is 1-1023. This control takes place before the scaler/deinterlacer. SUBCODE DESCRIPTION OF USE EXAMPLE: (LDV 500) - Set level detector to 500. All data greater than or equal to 500 will be shown in the...
Page 203
D-38Mirage WU-L User Manual020-100774-01 Rev. 2 4-2012 Appendix D: Serial Command Reference EXAMPLES: (LSH 1) - Turn OFF the LEDs. (LSH ?) - Report current logical shutter setting. (MCS) MENU CASCADING ENABLE CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Enable or disable cascading menus. When disabled, a single menu level will be displayed at a time. SUBCODE DESCRIPTION OF USE Enable or disable cascading. EXAMPLES: (MCS ?) - Get the current state of...
Page 204
Appendix D: Serial Command Reference Mirage WU-L User ManualD-39020-100774-01 Rev. 2 (4/2012) EXAMPLES: (MFT ?) - Get current font option used by the OSD. 0 is small font, 1 is large font. (MFT 1) - Use large font as the OSD font. (MLK) CHANNEL MEMORY LOCK CONTROL GROUP: Channel SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Lock a channel from being edited. SUBCODE C0xx DESCRIPTION OF USE Lock channel (xx=channel number from 01 to 99). MAIN Lock the channel being used by main....
Page 205
D-40Mirage WU-L User Manual020-100774-01 Rev. 2 4-2012 Appendix D: Serial Command Reference SUBCODE DESCRIPTION OF USE View/change the current state of the OSD (0=presentation, 1=main, 2=submenu). EXAMPLE: (MNU?)(MNU!0) (MSH) MENU SHIFT HORIZONTAL CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Change the horizontal position of the main menu. If the position is not from one of the preset positions, MSP will be changed to Custom. SUBCODE DESCRIPTION...
Page 206
Appendix D: Serial Command Reference Mirage WU-L User ManualD-41020-100774-01 Rev. 2 (4/2012) (NAM) CHANNEL NAME CONTROL GROUP: Channel SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Channel Name is optional text assigned to a channel and can appear in the Channel Setup menu, Channel Edit menu, the channel list and the Status menu. SUBCODE C0xx DESCRIPTION OF USE Set the channel name for the channel (xx=channel number from 01 to 99). MAIN Set the channel name for the channel...
Page 207
D-42Mirage WU-L User Manual020-100774-01 Rev. 2 4-2012 Appendix D: Serial Command Reference EXAMPLES: (NET+ETH0 192.168.1.35) - Set new IP address on the first ethernet controller. (NET+GATE 192.168.0.1) - Set the gateway. (NET+SUB0 255.255.255.0) - Set the subnet mask on the first ethernet controller. (NET+HOST MyHostName) - Set the host name. (NET+DOMA MyDomainName) - Set the domain name. (NET+ETH0 ?) - Get IP address from first controller. (NET+ETH0! 192.168.1.35). (NET+ETH1 ?) - Get IP address...
Page 208
Appendix D: Serial Command Reference Mirage WU-L User ManualD-43020-100774-01 Rev. 2 (4/2012) (NTR) NETWORK ROUTING CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Set routing for ASCII messages. SUBCODE DESCRIPTION OF USE Used to enable or disable daisy chaining. 0 = RS-232, RS-422 & Ethernet communications are all separate from one another 1 = RS-422 port(s) is/are connected to the RS-232 network 2 = The Ethernet port is connected to the RS-232...
Page 209
D-44Mirage WU-L User Manual020-100774-01 Rev. 2 4-2012 Appendix D: Serial Command Reference (OST) OSD TRANSPARENCY CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Enable or Disable on screen display transparency. SUBCODE DESCRIPTION OF USE Enable/Disable OSD transparency. EXAMPLE: (OST 1) - Enable OSD transparency. (PBC) PIP BORDER COLOR CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION This control lets you...
Page 210
Appendix D: Serial Command Reference Mirage WU-L User ManualD-45020-100774-01 Rev. 2 (4/2012) (PDT) PEAK DETECTOR CONTROL GROUP: Unsaved SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Enables or disables the peak detector test mode. This is used to aid in setup of Input levels. For each color, pixel values very near black will be displayed black, pixel values very near peak level will be displayed full on. All others will be displayed in mid-level grey. Input levels for each color...