J Series 1000W and 1200W User ManualB-1020-100706-02 Rev. 1 (03-2014) Appendix B: GPIO This section explains how to use a GPIO link from the projector to external equipment, such as devices for 3D synchronizing. B.1 GPIO Port The GPIO connector located on the input panel provides a flexible method of interfacing a wide range of external I/O devices to the projector. There are 7 GPIO pins available on the 9pin D-Sub GPIO connector, which are configurable via RS-232 commands. The other two pins are reserved for ground and power - see table below for pin identification. Table B.1 GPIO Pin The serial cable required for connecting the external device to the projector GPIO connector, must be compatible with th e external device. GPIO PINS PIN #SIGNAL Pin 1 + 12V (200mA) Pin 2 GPIO 2 Pin 3 GPIO 4 Pin 4 GPIO 6 Pin 5 Ground Pin 6 GPIO 1 Pin 7 GPIO 3 Pin 8 GPIO 5 Pin 9 GPIO 7
B-2J Series 1000W and 1200W User Manual020-100706-02 Rev. 1 (03-2014) Appendix B: GPIO Configuring the GPIO The GPIO connector can be configured to automate any number of events using the serial command code GIO . Each Pin is defined as either an input or output depending on the desired outcome. Configure the pin as an input if you want the projector to respond to somethin g the device does and as an output if you want the external device to respond to an action taken by the proj ector. For example, configure the pin as an output if you want the lighting in a room to automatic ally dim when the projector is turned on. By using the GIO command, you can also set the state of each output pin as high or low . By default, the state of each pin is high. The voltage applied to pins in the high state is +3.3V. A low state (or value of 0) will be read on an input pin if the circuit attached to the pin is open. A high state (or value of 1) will be read on an input pin if the circuit attached to the pin is shorted to ground. This corresponds to a switch closing event. Example 1. Turn room lighting on when th e projector is turned off. (Assumes a control/automation unit is configured to turn the lights on when pin 2 of its input goes high. ) NOTE: The strings in the commands refer to pins 2, 3, 4, 6, 7, 8, 9 in order from left to right. (GIO+CNFG “OOOIIII”) Set pin #2, 3 & 4 configuration to output and pin 6, 7, 8 & 9 to input (GIO+STAT “HLXXXXX”) Set pin #2 to high, pin 3 to low and the state of all other pins unchanged Query Command (GIO+STAT) Request the state of all pins (GIO+STAT “HLLHLLH”) Reply of pin st ates - H means pin is high, L means pin is low (GIO+CNFG) Request the configuration of all pins (GIO+CNFG “IIIOOOO”) Reply of pin configurations - pins 2, 3 & 4 are Inputs, pins 6, 7, 8 & 9 are Outputs PinOpen (0 or L) PinClosed (1 or H)
J Series 1000W and 1200W User ManualC-1020-100706-02 Rev. 1 (03-2014) Appendix C: DMX / ArtNet C.1 DMX and Real Time Events What is DMX? DMX is a standard for digital communication networks that are commonly used to control stage lighting and effects. What is Real Time Events? A real time event is a pre-recorded sequence of 1 or mo re serial commands which are executed when a defined trigger occurs. For example: • A trigger can be timed base d (i.e. Saturday at 1:00pm; occurring every other week) • A trigger can be event based (i.e. System powers on, good signal, etc.) • A trigger can be a number of other events (For more details, refer to 4.3.7 Advanced Tabbed Page - RTE ) NOTE: A real time event can use nested loops and delays. Only statically defined commands can be executes (i.e. PWR 0, SHU 1). You cannot use variables or other complex programming techniques. Lens Control Limit i at ions WARNING: Normal ILS control of the lens horizontal and vertical positions by the projector respects the boundaries of the lens keep out area. This area is necessary to prevent damage to components within the projector. When the DMX controls are used to set the abso lute position of the lens, setting values in these keep out areas may result in an unwanted fina l lens position. You must ensure that any interim or final lens positions, at any time during the lens moveme nt, do not enter the keep out area. FIGURE C-1 LENS CONTROL LIMITATIONS Keep Out Keep Out Facing Screen 2050 0 -100 -2050 2050 100 0 -400 -2050
C-2J Series 1000W and 1200W User Manual020-100706-02 Rev. 1 (03-2014) Appendix C: DMX / ArtNet C.1.1 DMX Channel Setup Each personality has a different number of channels: • Setup Personality - 38 channels • Show Personality - 18 channels • ZAP VIP Projector Yoke Personality - 25 channels It is very important to properly configure the base ch annel (depending on which personality is used) correctly. While the DMX specification allows fo r device overlapping, this may cause undesired results. Below is a table of how projectors should be configur ed (assuming that all projectors are to be controlled independently and use the same personality): Table C.1 “Show personality” Co rrect Example Table C.2 “Setup personality” Correct Example Base Channel All projectors using Show Personality (Correct) Base Channel All projectors using Setup Personality (Correct) 1 Projector 1 (18 ch) 1 Projector 1 (38 ch) 19 Projector 2 (18 ch) 39 Projector 2 (38 ch) 37 Projector 3 (18 ch) 77 Projector 3 (38 ch) Table C.3 “Show personal ity” Incorrect Example Base Channel All projectors using Show Personality (Incorrect) 1 Projector 1 (18 ch) 1 Projector 2 (18 ch) 12 Projector 3 (18 ch)
Appendix C: DMX / ArtNet J Series 1000W and 1200W User ManualC-3020-100706-02 Rev. 1 (03-2014) Setup Personality Channel Group NameDescriptionDefault Va l u e Notes 1 Safety Slider Lock 0-171 Locked 172-255 Unlocked255No Channel changes will be applied when this control is locked. Channel changes made while the slider is locked will be applied once the slider becomes unlocked. 2 Video Fade to/from Black 0-85 Black screen (Picture mute ON) 172-255 Live Video (P icture mute OFF) 255If you wish to manually con- trol the fade to black time, the brightness channel can be used to achieve the same effect. 3 Lens Shutter 0-85 Shutter Closed (Black Screen) 172-255 Shutter Open (Live Video) 255 4 LensLens shift enable 0-85 Lens shift disable 172-255 Lens shift enable 255 Locks all lens motors. 5 Lens Zoom (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 2100 125 Locked by channel “Lens shift enable”. 6 Lens Zoom (Fine) 0 7 Lens Zoom (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 2100 128 Locked by channel “Lens shift enable”. 8 Lens Zoom (Fine) 0 9L en s Lens Horizontal position (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 4096 128 Locked by channel “Lens shift enable” 10 Lens Lens Horizontal position (Fine) 0 11 L e ns Lens Vertical position (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 4096 128 Locked by channel “Lens shift enable” 12 Lens Lens Vertical position (Fine) 0 13 Input Channel Projector Channel Selection 0 to 9 Projector Channel 1 10 to 19 Projector Channel 2 20 to 29 Projector Channel 3 .... 180 to 189 Projector Channel 19 190 to 199 Projector Channel 20255
C-4J Series 1000W and 1200W User Manual020-100706-02 Rev. 1 (03-2014) Appendix C: DMX / ArtNet Channel Group NameDescriptionDefault Va l u e Notes 14 Input Input Input Selection 0 to 9 Slot 1, Input 1 10 to 19 Slot 1, Input 2 .... 50 to 59 Slot 1, Input 6 60 to 69 Slot 2, Input 1 .... 110 to 119 Slot 2, Input 6 120 to 129 Slot 3, Input 1 .... 170 to 179 Slot 3, Input 6 180 to 189 Slot 4, Input 1 .... 230 to 239 Slot 4, Input 6255 Will not change input on default 15 Image Image Freeze 0-85 Unfreeze image 172-255 Freeze Image0 16 Lamps/ Power Power 0-85 Power Off (Switch lamps off, cool lamps down and go to Standby mode) 172-255 Power On (Switch lamps on, warm up mode) 128A 5 second timer will be used before executing a power state change. If th e slider moves out of the On/Off range within the 5 seconds, the timer will be cancelled. Will not change power stat on default. 17 Image Size 0 to 255 Scaled as % of total control range, which is 200 to 400067 18 Image Vertical Stretch 0 to 255 Scaled as % of total control range, which is 200 to 300091 19 Setup Functions Projector Orientation 0-49 Front Projection 50-99 Rear Projection 100-149 Front Projection Inverted 150-199 Rear Projection Inverted 255 Will not change projector ori- entation on default. 20 Setup Functions On Screen Display 0-85 OSD Off 172-255 OSD On 128Will not change OSD on default. 21 Setup Functions Lens Calibrate 172-255 Run calibration 0 Locked by channel “Lens shift enable”. 22 Setup Functions Lamp Power Scaled as % of total control range. 0 minimum .... 127 mid-range .... 255 maximum 255 Depends on what lamps are used, power rating may be dif- ferent scale. 23 Reserved Reserved for future expansion 0
Appendix C: DMX / ArtNet J Series 1000W and 1200W User ManualC-5020-100706-02 Rev. 1 (03-2014) Channel Group NameDescriptionDefault Va l u e Notes 24 Setup Func- tions Test Pattern 0-19 Off 20-39 Grid 40-59 Grey Scale 16 60-79 White 80-99 Flat Grey 100-119 Black 120-139 Checker 140-159 13 Point 160-179 Color Bars 180-199 Aspect Ratio 200-219 Edge Blend 220-239 Boresight 0 25 Colorimetry Brightness 0 to 255 Scaled as % of total control range, which is 0 to 100128 26 Colorimetry Contrast 0 to 255 Scaled as % of total control range, which is 0 to 100128 27 Colorimetry Gamma 0 to 255 Scaled as % of total control range, which is -100 to 100128 28 Colorimetry Color Space 0-49 RGB 50-99 YCbCr SDTV (ITU-R BT.601) 100-149 YCbCr HDTV (ITU-R BT.709)0 29 Colorimetry Output Color 0-19 Max Drivers 20-39 Color Temperature (enables 31) 40-59 SD Video 60-79 HD Video 80-99 User setting 1 100-119 User setting 2 120-139 User setting 3 140-159 User setting 40 30 Colorimetry Color Purity Filter0-85 CPF Off 172-255 CPF On This is the global CPF control, not the channel control. 0 31 Colorimetry Interpolated Color (Temperature)*0 to 255 Scaled as % of total control range, which is 3200 to 9300 128*Output Color control must be set to “Color Temperature” in DMX channel 29 32 Advanced Image Blend enable 0-19 Blend disable 20-39 Standard Blend enable 40-59 User Blend 1 enable 60-79 User Blend 2 enable .... 220-239 user Blend 10 enable 0 The list of blends depends on the blends having been saved on the projector by the user. 33 Advanced Image Warp/keystone enable 0-19 Warp/keystone disable 20-39 2D Keystone enable 40-59 Warp 1 enable .... 220-239 Warp 10 enable 0 The list of warps depends on the warps having been saved on the projector by the user.
C-6J Series 1000W and 1200W User Manual020-100706-02 Rev. 1 (03-2014) Appendix C: DMX / ArtNet Channel Group NameDescriptionDefault Va l u e Notes 34 Real Time Events RTE 1 0-85 Cancel current running RTE 172-255 Triggers RTE 1 128 35 Real Time Events RTE 2 0-85 Cancel current running RTE 172-255 Triggers RTE 2 128 36 Real Time Events RTE 3 0-85 Cancel current running RTE 172-255 Triggers RTE 3 128 37 Reserved Reserved for future expansion No reset 38 Reserved Reserved for future expansion No reset J Series Show Personality Channel Group NameDescriptionDefault Va l u e Notes 1 Safety Slider Lock0-171 Locked 172-255 Unlocked 255No channel cha nges will be applied when this control is locked. Channel changes made while the slider is locked will be applied once the slider becomes unlocked. 2Video Fade to/from Black0-85 Black screen (Picture mute ON) 172-255 Live video (P icture mute OFF) 255If you wish to manually con- trol the fade to black time, the brightness channel can be used to achieve the same effect. 3L en s Shutter 0-85 Shutter Closed (Black Screen) 172-255 Shutter Open (Live Video) 255 4L en s Lens shift enable 0-85 Lens shift disable 172-255 Lens shift enable 255 Lock all lens motors. 5L en s Zoom (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 2100 128 Locked by channel “Lens shift enable”. 6L en s Zoom (Fine) 0 7L en s Focus (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 2100 128 Locked by channel “lens shift enable”. 8L en s Focus (Fine) 0 9L en s Lens Horizontal position (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 4096 128 Locked by channel “lens shift enable”. 10 Lens Lens Horizontal position (Fine) 0 11 L en s Lens Vertical position (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 4096 Locked by channel “lens shift enable”. 12 Lens Lens Vertical position (Fine)
Appendix C: DMX / ArtNet J Series 1000W and 1200W User ManualC-7020-100706-02 Rev. 1 (03-2014) Channel Group NameDescriptionDefault Va l u e Notes 13 Input ChannelProjector Channel Selection 0 to 9 Projector Channel 1 10 to 19 Projector Channel 2 20 to 29 Projector Channel 3 .... 180 to 189 Projector Channel 19 190 to 199 Projector Channel 20 255 14 Input InputInput Selection 0 to 9 Slot 1, Input 1 10 to 19 Slot 1, Input 2 .... 50 to 59 Slot 1, Input 6 60 to 69 Slot 2, Input 1 .... 110 to 119 Slot 2, Input 6 120 to 129 Slot 3, Input 1 .... 170 to 179 Slot 3, Input 6 180 to 189 Slot 4, Input 1 .... 230 to 239 Slot 4, Input 6 255 Will not change input on default. 15 Image Image Freeze0-85 Unfreeze image 172-255 Freeze image 0 16 Lamps/ Power Power 0-85 Power Off (Switch lamps off, cool lamps down and go to Standby mode) 172-255 Power On (Switch lamps on, warm up mode) 128A 5 second timer will be used before executing a power state change. If the slider moves out of the On/Off range within the 5 seconds, the timer will be cancelled. Will not change power state on default. 17 Reserved Reserved for future expansion No Reset 18 Reserved Reserved for future expansion No Reset ZAP VIP Projector Yoke Personality Channel Group NameDescriptionDefault Va l u e Notes 1Video Fade to/from Black0-85 Black screen (Picture mute ON) 172-255 Live video (Picture mute OFF) 0 Shutter Closed 1-255 Shutter Open 255If a value of 0 is set, the shut- ter will be closed. Any non- zero values will open the shut- ter. If you wish to manually control the fade to black time, the brightness channel can be used to achieve the same effect.
C-8J Series 1000W and 1200W User Manual020-100706-02 Rev. 1 (03-2014) Appendix C: DMX / ArtNet Channel Group NameDescriptionDefault Va l u e Notes 2L en s Shutter 0-85 Shutter Closed (Black Screen) 172-255 Shutter Open (Live Video) 255 3L en s Lens shift enable 0-85 Lens shift disable 172-255 Lens shift enable 255 Locks all lens motors 4L en s Zoom (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 2100 128 Locked by channel “Lens shift enable”. 5L en s Zoom (Fine) 0 6L en s Focus (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 2100 128 Locked by channel “Lens shift enable”. 7L en s Focus (Fine) 0 8 LensLens Horizontal position (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 2100 128 Locked by channel “Lens shift enable”. 9 LensLens Horizontal position (Fine) 0 10 LensLens Vertical position (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 2100 128 Locked by channel “Lens shift enable”. 11 LensLens Vertical position (Fine) 0 12 InputInput Projector Channel Selection 1 to 20 Projector Channel 1 to 20 86 LOAD Input Selection 111 to 116 Slot 1, Input 1 to 6 121 to 126 Slot 2, Input 1 to 6 131 to 136 Slot 3, Input 1 to 6 141 to 146 Slot 4, Input 1 to 6 171 EXECUTE 255 13 Image Size 0 to 255 Scaled as % of total control range, which is 200 to 4000 67 14 Image Vertical Stretch 0 to 255 Scaled as % of total control range, which is 200 to 3000 91