3 - 20 CONTROL PANEL NETWORK (only on a Network) Display ShowsDescription TCP/IPSubsetting Description TCP/IP ENABLE=ON/OFF IP ADDRESS=###.###.###.### SUBNET MASK=###.###.###.### GATEWAY=###.###.###.### IP BOOT TRIES=# IP METHOD=AUTO, STATIC, RARP, BOOTP, DHCP APIPA=ON/OFF NETWARE NETWARE ENABLE=ON/OFF NET FRAME=AUTO, 8023, ENET, 8022, SNAP APPLETALK=ON/OFF NETBEUI=ON/OFF DLC/LLC=ON/OFF NETBIOS/IP=ON/OFF ENET=AUTO, 100B-FD, 100B-HD, 10B-FD, 10B-HD
CONTROL PANEL 3 - 21 INTERFACE Display ShowsDescription SELECT=AUTO/PARALLEL/USB/NETWORK AUTO IF TIME= 1, 2, 3 ... 99 (sec) You need to set the time-out period for the auto interface selection. INPUT BUFFER= Level1, 2, 3 ... 15 Increases or decreases the input buffer capacity.RESTART PRINTER? PARALLELWhen using the parallel interface Sub-setting Menu Description HIGH SPEED=ON/OFF Turns high-speed parallel communications ON or OFF. BI-DIR=ON/OFF Turns bi-directional parallel communications ON or OFF. INPUT PRIME=ON/OFF Turns prime signal ON or OFF. USB 2.0 HIGH SPEED=ON/OFF Turns High-Speed USB 2.0 communications ON or OFF. RESET MENU Display ShowsDescription RESET PRINTERResets the printer and restores all printer settings (including command settings) to settings you have previously made with the control panel buttons. FACTORY RESETResets the printer and restores all printer settings (including command settings) to the factory settings. See List of factory settings on page 3-24.
3 - 22 CONTROL PANEL Set IP Address Press the + or - button until NETWORK appears (and to display each setting shown below). Press the Set button. Press the Set button. Press the + button. Press the Set button. The last digit in the first part of the number is blinking. Press the + or - button to increase or decrease the number. Press the Set button to go to the next number. Repeat this process until you have set your IP address. Press the Set button to complete the IP address. An asterisk appears at the end of the display. INFORMATION NETWORK TCP/IP TCP/IP ENABLE IP ADDRESS= 192.0.0.192* 123.0.0.192* 123.45.67.89 123.45.67.89*
CONTROL PANEL 3 - 23 About emulation modes This printer has the following emulation modes. HP LaserJet Mode The HP LaserJet mode (or HP mode) is the emulation mode in which this printer supports the PCL6 language of the Hewlett-Packard LaserJet laser printer. Many software applications support this type of laser printer. Using this mode will allow your printer to operate at its best with those applications. BR-Script 3 Mode BR-Script is an original Brother page description language and a PostScript® language emulation interpreter. This printer supports level 3. The BR-Script interpreter of this printer allows you to control text and graphics on pages. For technical information about PostScript ® commands, see the following manuals: ■Adobe Systems Incorporated. PostScript ® Language Reference, third Edition. Addison-Wesley Publishing Company, Inc., 1999. ISBN: 0-201-37922-8 ■Adobe Systems Incorporated. PostScript ® Language Program Design. Addison-Wesley Publishing Company, Inc., 1988. ISBN: 0-201-14396-8 ■Adobe Systems Incorporated. PostScript ® Language Tutorial and Cookbook. Addison-Wesley Publishing Company, Inc., 1985. ISBN: 0-201-10179-3 EPSON FX-850 and IBM Proprinter XL Mode The EPSON FX-850 and IBM Proprinter XL modes are the emulation modes that this printer supports to meet the industry-standard for dot matrix printers. Some applications support these dot matrix printer emulations. Use these emulation modes so your printer will work well when printing from those types of applications.
3 - 24 CONTROL PANEL List of factory settings Table 3-1 shows the factory settings. Network factory default setting If you wish to reset the print server back to its default factory settings (resetting all information such as the password and IP address information), hold down the network test button on the network board (NC-6100h) for more than 5 seconds. ■The emulation mode affects the setting. Effective modes are shown in brackets in the following table. ■The following settings cannot be restored to the factory settings with FACTORY RESET in the RESET MENU menu: INTERFACE menu, HRC, PAGE PROTECTION, SCALABLE FONT, LOCK PANEL, page counter and local language for display messages. ■The COPY setting is always restored to the factory setting when the printer is turned off and on again.
CONTROL PANEL 3 - 25 Table 3 - 1: List of factory settings Display ShowsSubmenuFactory setting PAPER SOURCE=AUTO PRIORITY=MP>T1>T2 MP FIRST=OFF MP SIZE=ANY MANUAL FEED=OFF TRAY1 SIZE=DETECT SENSOR TRAY2 SIZE=DETECT SENSOR DUPLEX=OFF QUALITY RESOLUTION=600 HRC=MEDIUM TONER SAVE=OFF DENSITY0 SETUP LANGUAGE=ENGLISH PANEL CONTROLSubsetting Factory setting LCD DENSITY =0 AUTO ONLINE =ON BUTTON REPEAT =0.1 SEC MESSAGE SCROLL LEVEL 1 ERROR BUZZER=OFF PANEL BUZZER=OFF BUZZER VOLUME=LOW POWER SAVE TIME=30 MIN AUTO CONTINUE=OFF LOCK PANEL=OFF REPRINT=ON PAGE PROTECTION=AUTO EMULATION=AUTO(EPSON) KEEP PCL=OFF RAMDISK SIZE=0MB PRINT MENU MEDIA TYPE=PLAIN PAPER PAPER=A4/LETTER COPIES=1 ORIENTATION=PORTRAIT PRINT POSITIONSubsetting Factory setting X OFFSET=0 Y OFFSET=0 AUTO FF TIME=0 FF SUPPRESS=OFF
3 - 26 CONTROL PANEL PRINT MENU (continued)HP LASERJETSubsetting Factory setting FONT NO. =59 FONT PITCH =10.00/12.00 SYMBOLSET =PC8 AUTO LF =OFF AUTO CR =OFF AUTO WRAP =OFF AUTO SKIP =ON LEFT MARGIN =#### RIGHT MARGIN =#### TOP MARGIN =#### BOTTOM MARGIN =#### LINES =#### EPSON FX-850FONT NO. =59 FONT PITCH =10.00/12.00 SYMBOLSET =US ASCII AUTO LF =OFF AUTO MASK =OFF LEFT MARGIN =#### RIGHT MARGIN=#### TOP MARGIN=#### BOTTOM MARGIN=#### LINES=#### IBM PROPRINTER FONT NO.=59 FONT PITCH=10.00/12.00 SYMBOLSET=PC8 AUTO LF=OFF AUTO CR=OFF LEFT MARGIN=#### RIGHT MARGIN=#### TOP MARGIN=#### BOTTOM MARGIN=#### LINES=#### BR-SCRIPTERROR PRINT=OFF CARBON MENUCARBON COPY=OFF Table 3 - 1: List of factory settings (Continued) Display ShowsSubmenuFactory setting
CONTROL PANEL 3 - 27 *1 Automatic Private IP Addressing (APIPA) protocol automatically configures an IP address and subnet mask. For more details, see the Network Users Guide, which is provided on the CD-ROM. NETWORK TCP/IPSubsetting Factory setting TCP/IP ENABLE=ON IP ADDRESS=169.254.###.### * 1 SUBNET MASK =255.255.0.0 *1 GATEWAY=0.0.0.0 IP BOOT TRIES=3 IP METHOD=AUTO APIPA=ON NETWARENETWARE ENABLE=ON NET FRAME=AUTO APPLETALK=ON NETBEUI=ON DLC/LLC=ON NETBIOS/IP=ON ENET=AUTO INTERFACE SELECT=AUTO AUTO IF TIME=5 INPUT BUFFER=LEVEL 3 PARALLELSubsetting Factory setting HIGH SPEED=ON BI-DIR=ON INPUT PRIME =OFF USB 2.0HIGH SPEED=ON Table 3 - 1: List of factory settings (Continued) Display ShowsSubmenuFactory setting
3 - 28 CONTROL PANEL For visually-impaired users Buzzer indications The control panel has a buzzer. The buzzer will sound when one of the control panel buttons is pressed, or the status of the printer changes. See the table for a description of the buzzer meanings. You can change the settings of the buzzer by using the buttons on the control panel. To change the setting of the buzzer, press the + (plus) button until SETUP is displayed, then press the Set button. Press the + (plus) button until ERROR BUZZER, PANEL BUZZER or BUZZER VOLUME is displayed and press Set. See SETUP on page 3-16 for a description of the buzzer settings. Table 3 - 2: Buzzer indications list Buzz indicationsConditions A short buzz ■When you enter any information using the button. Two short buzzes■When you come back to the top menu option after you move forward or backward through the menus. ■When you move to another menu level. Five short buzzes■When an error occurs. A long buzz■When you set any optional menu setting. Two long buzzes■When the printer comes online. ■When the printer is in the READY status after a warming up condition. A short and a long buzz■When you enter wrong information.
CONTROL PANEL 3 - 29 Braille symbols The control panel buttons are marked with Braille characters for visually-impaired users as shown in the table. *Braille indicates the first 2 or 3 letters of the English button name. For example, Job Cancel is shown as “can” in Braille. The control panel with Braille symbols is optionally available for some countries. If you want to buy an optional control panel with Braille symbols, call the dealer you bought the printer from. Table 3 - 3: Braille symbols list ButtonAbbreviationsBraille* Go Go Job Cancel Can Reprint Rep