Page 81
INSTALLATION MICROWAVE INTERFACEMICROWAVE INTERFACE LIGHT-GUIDE INTERFACELIGHT-GUIDE INTERFACE INFRARED INTERFACEINFRARED INTERFACE 655 FEET MAXIMUM ANY DS1 INTERFACE655 FEET MAXIMUM ANY DS1 INTERFACE Install *DSX-1 REFERS Figure 2-24.DS1 Customer Service TO A PHYSICAL CROSS-CONNECT FOR DS1 SIGNALS Connections—Non Metallic Connections Unit (CSU) The CSU may either be rack mounted or mounted as a standalone unit. It can be equipped with several different plug in units, the Signal Monitor Unit, T1 Office...
Page 82
INSTALLATION Connect the CSU The CSU can be powered by the line or from a locally provided -48 V dc power supply. Figure 2-25 shows the connections for connecting the CSU. The 48 V and GRD leads are optional according to how the CSU is powered. H600 307 ,02 CONNECTOR CABLE (NOTE) NOTE : FOR DISTANCES OVER 50 FEET ( 15.2 M) USE C6E CONNECTOR CABLE(S) BETWEEN H600 307,02 CONNECTOR CABLE AND DS1 TRUNK CIRCUIT PACK .TO LOCALLY PROVIDED -48V POWER SUPPLY Figure 2-25.CSU Connections Line...
Page 83
INSTALLATION Consideration should be given to installing secondary protection on each out-of-building facility connected to the TAE if any of the following conditions exist: l The service entrance (protector block) ground is not properly installed (bonded to building ground, for example). l The local telephone company does not permit access to the protector block. lHigh-voltage surge protection is not provided. Install the CBC as follows: 1.Connect one end of the CBC to the ground point at the network...
Page 84
INSTALLATION INSTALL EQUIPMENT ROOM STATION CABLING System 25 is connected to the building (station) wiring in two stages. First, the building wiring is connected to the Station Interconnect Panel (SIP). Then, the octopus cables from the back of the cabinets are connected to the SIP. Accurate documentation during installation is essential to the performance and maintenance of System 25 and will make initialization and administration much easier to perform.The Voice and Data Station Records Form (Figure...
Page 86
INSTALLATION Connect Building Wiring to SIP The type of building wiring termination determines what types of adapters are used. Two types are supported: 4-pair cable (cut down) and modular jack. Any combination of adapters may be mounted on a 617A Panel. Cluster the connection on the SIP by voice terminal type: single-line, 7300H Series*, Multibutton Electronic Telephone (MET), and voice/data. Modular Plug Termination Each 4-pair modular plug supports one station (Figure 2-27). It connects to a modular...
Page 87
INSTALLATION Z21OA1 ADAPTER (MODULAR TO MODULAR)PURSELOCK CLIP / ( TYPICAL) Figure 2-27.Modular Plug Terminations Connected to the SIP 2-63
Page 88
INSTALLATION 4-Pair Cable Terminations Each 4-pair cable supports one station (Figure 2-28). It connects to a wiring block on a 858A Adapter. 1. 2. 3. 4. 5. 6. Run the 4-pair cable through the rings at the top of the 617A Panels. Cut down the leads starting with Pin 1 of the wiring block located beside the modular jack (Figure 2-28). Wiring BlockDIW Cable Pin No.Color Code 1W-BL 2BL-W 3W-O 4O-W 5W-G 6G-W 7W-BR 8BR-W Using a felt-tipped pen, record the building wiring destination on the wiring block...
Page 89
INSTALLATION ZZ1OA1 ADAPTER (MODULAR TO MODULAR) PURSE LOCK CLIP (TYPICAL) Figure 2-28.Cut Down Terminations Connected to the SIP 2-65
Page 90
INSTALLATION Connect Cabinets to SIP Table 2-E shows the type of terminals that can be connected to each CP type and the maximum allowable cabling distances to the system cabinets. Refer to the Voice and Data Station Records Form for the terminal types assigned to each workstation. Caution:Connecting a terminal to the wrong type of CP can damage the pack. Table 2-E.Circuit Pack Versus Terminal Type Circuit PackTerminal TypeDistance (in feet) From Cabinets Using 24 AWG Wire ZTN797300H Series and ATL2,000...