Page 121
INSTALLATION 4.Connect the cable to a protection device at the System 25 location. 5. Connect the second protection device to an 858A Adapter on the617A Panel, using 4-pair inside wiring cable. 6. Connect the 858A Adapter to a port on a TN742 circuit pack using an octopus cable. Out-of-Building Voice Terminals (ZTN79) Transmission facilities (voice pairs) that extend out-of-building and are not included in the interface may be installed by the telephone company or through other means (e.g., the building...
Page 122
INSTALLATION H600 307 .G2 CONNECTOR CABLE (NOTE) TO D4 CHANNEL BANK NOTE; FOR DISTANCES OVER 50 FEET (15.2 M) USE C6E CONNECTOR CABLE(S) BETWEEN H600 307 .G2 CONNECTOR CABLE AND DS1 TRUNK CIRCUIT PACK.TO LOCALLY PROVIDED -48V POWER SUPPLY Figure 2-41. DS1 to D4 Connections for Off-Premises Stations 2-97
Page 123
INSTALLATION Stand-Alone Data Terminals Data terminals and computers may be connected to the system through ADUs or a Multiple Asynchronous Data Unit (MADU) without being linked to a voice terminal. Depending on the data terminal that they connect to, some ADUs may need supplementary power for proper operation. See Figures 2-42 and 2-43. ADU Connections 1. 2. 3. Unpack the ADU and examine for damage. At the workstation, connect the ADU connector to the RS-232C receptacle of the terminal or computer....
Page 124
INSTALLATION LEGEND : . B1 -TYPICAL -103A CONNECTING BLOCK C1 –MODULAR CORD (D8W-87) C7–MODULAR POWER CORD (D6AP-87) W1-4-PAIR INSIDE BUILDING WIRING CABLE 248B ADAPTER-ALLOWS MODULAR JACK CONNECTION FROM 2012D TRANSFORMER 400B2 ADAPTER-POWER ADAPTER 2012D TRANSFORMER - 15-18V AC TRANSFORMER Z3A1 ADU -EQUIPPED WITH A 3 FOOT PLUG-ENDED EIA CORD Z3A4 ADU -EQUIPPED WITH A 3 FOOT RECEPTACLE-ENDED EIA CORD Figure 2-42.Local Powering of an ADU 2-99
Page 125
INSTALLATION LEGEND : TN726 -DATA LINE CP B1- TYPICAL -103A CONNECTING BLOCK Cl-MODULAR CORD (D8W-87) C7-MODULAR CORD (D6AP-87) P2-MODULAR BULK POWER SUPPLY POWER UNIT (346A) POWER PANEL (346A-1) W1-4-PAIR INSIDE WIRING CABLE Z3A1 ADU -EQUIPPED WITH A 3 FOOT PLUG-ENDED EIA CORD Z3A4 ADU -EQUIPPED WITH A 3 FOOT RECEPTACLE-ENDED EIA CORD Figure 2-43.Remote Powering of an ADU (Optional) 2-100
Page 126
INSTALLATION MADU Connections The MADU provides a direct connection to a host computer or a large group of data terminals (64 maximum). See Figure 2-44. The MADU has eight port connectors; each port is equivalent to a single ADU. Complete installation instructions for the MADU are contained in the MADU Product Guide (999- 700-525). SYSTEM 25 CABINET LEGEND : TN726 - DATA LINE CP MADU - MULTIPLE ASYNCHRONOUS DATA UNIT SINGLE UNIT ASSEMBLY (8 ADU PORTS) W2 - BUILDING WIRING ( 25-PAIR CABLE) C10 - 25-PAIR...
Page 127
INSTALLATION INSTALL CUSTOMER’S SAT The SAT can be connected through the SIP to the CPU/Memory CP by any one of the following methods: l On-premises nonswitched connection (no ADU required if the SAT is plugged into the system AC outlet) l On-premises switched connection l Off-premises nonswitched connection l Off-premises switched connection. SMDR equipment can also be connected by any of the four methods listed above.The DTU can be connected only by the on-premises nonswitched connection. Nonswitched...
Page 128
INSTALLATION LEGEND : ZTN129-CPU/MEMORY CP C1-MODULAR CORD (D8W-87) C2 -OCTOPUS CABLE (WP90780) 355A ADAPTER -RS-232 PLUG TO MODULAR JACK 355AF ADAPTER -RS-232 RECEPTACLE TO MODULAR JACK * PERIPHERAL EQUIPMENT l SYSTEM ADMINISTRATION TERMINAL (LEG 1 OF OCTOPUS CABLE) l DIGITAL TAPE UNIT (LEG 3 OF OCTOPUS CABLE) l SMDR OUTPUT DEVICE (LEG 2 OF OCTOPUS CABLE) Figure 2-45.Nonswitched Connection of Peripheral Equipment Plugged into System AC Outlet 2-103
Page 129
Nonswitched See Figure 2-46. Connection of Equipment Note:Figure 2-46 shows an Z210A1 SIP Adapter to provide the building wiring termination.An 858A Adapter can also be 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. used. Connect the RS-232C plug on the peripheral 232C port on a Z3A1 or Z3A4 ADU. Always other fasteners on this connection.equipment to the RS- tighten the screws or Connect the ADU to the building wiring with a D8W-87 modular telephone cord. At the SIP, connect the building wiring termination to an...
Page 130
INSTALLATION LEGEND : B1–TYPICAL -103A CONNECTING BLOCK C1-MODULAR CORD (D8W-87) C2 -OCTOPUS CABLE (WP90780) C3-EIA CROSSOVER CABLE (P17U-87) C4 -MODULAR RECEPTACLE TO MODULAR PLUG ADU CROSSOVER (D8AM-87) C7-MODULAR POWER CORD (D6AP-87) W1-INSIDE BUILDING WIRING CABLE 248B ADAPTER-ALLOWS MODULAR JACK CONNECTION FROM 2012D TRANSFORMER 355AF ADAPTER RS-232 RECEPTACLE TO MODULAR JACK 2012D TRANSFORMER - 15-18V AC TRANSFORMER Z3A1 ADU -EQUIPPED WITH A 3-FOOT PLUG-ENDED EIA CORD Z3A4 ADU -EQUIPPED WITH A...