INSTALLATION
4.Connect the cable to a protection device at the System 25 location.
5. Connect the second protection device to an 858A Adapter on the617A
Panel, using 4-pair inside wiring cable.
6. Connect the 858A Adapter to a port on a TN742 circuit pack using an
octopus cable.
Out-of-Building Voice Terminals (ZTN79)
Transmission facilities (voice pairs) that extend out-of-building and are not
included in the interface may be installed by the telephone company or through
other means (e.g., the building...

Page 122

INSTALLATION
H600 307 .G2
CONNECTOR
CABLE (NOTE)
TO D4
CHANNEL
BANK
NOTE; FOR DISTANCES OVER 50 FEET (15.2 M)
USE C6E CONNECTOR CABLE(S) BETWEEN
H600 307 .G2 CONNECTOR CABLE AND DS1
TRUNK CIRCUIT PACK.TO LOCALLY
PROVIDED -48V
POWER SUPPLY
Figure 2-41.
DS1 to D4 Connections for Off-Premises Stations
2-97 

Page 123

INSTALLATION
Stand-Alone Data Terminals
Data terminals and computers may be connected to the system through
ADUs or a Multiple Asynchronous Data Unit (MADU) without being linked to a
voice terminal. Depending on the data terminal that they connect to, some
ADUs may need supplementary power for proper operation. See Figures
2-42 and 2-43.
ADU Connections
1.
2.
3.
Unpack the ADU and examine for damage.
At the workstation, connect the ADU connector to the RS-232C
receptacle of the terminal or computer....

Page 124

INSTALLATION
LEGEND :
.
B1 -TYPICAL -103A CONNECTING BLOCK
C1 –MODULAR CORD (D8W-87)
C7–MODULAR POWER CORD (D6AP-87)
W1-4-PAIR INSIDE BUILDING WIRING CABLE
248B ADAPTER-ALLOWS MODULAR JACK CONNECTION FROM
2012D TRANSFORMER
400B2 ADAPTER-POWER ADAPTER
2012D TRANSFORMER -
15-18V AC TRANSFORMER
Z3A1 ADU -EQUIPPED WITH A 3 FOOT PLUG-ENDED EIA CORD
Z3A4 ADU -EQUIPPED WITH A 3 FOOT RECEPTACLE-ENDED EIA CORD
Figure 2-42.Local Powering of an ADU
2-99 

Page 125

INSTALLATION
LEGEND :
TN726 -DATA LINE CP
B1- TYPICAL -103A CONNECTING BLOCK
Cl-MODULAR CORD (D8W-87)
C7-MODULAR CORD (D6AP-87)
P2-MODULAR BULK POWER SUPPLY
POWER UNIT (346A)
POWER PANEL (346A-1)
W1-4-PAIR INSIDE WIRING CABLE
Z3A1 ADU -EQUIPPED WITH A 3 FOOT PLUG-ENDED EIA CORD
Z3A4 ADU -EQUIPPED WITH A 3 FOOT RECEPTACLE-ENDED
EIA CORD
Figure 2-43.Remote Powering of an ADU (Optional)
2-100 

Page 126

INSTALLATION
MADU Connections
The MADU provides a direct connection to a host computer or a large group
of data terminals (64 maximum). See Figure 2-44. The MADU has eight port
connectors; each port is equivalent to a single ADU. Complete installation
instructions for the MADU are contained in the MADU Product Guide (999-
700-525).
SYSTEM 25
CABINET
LEGEND :
TN726 - DATA LINE CP
MADU - MULTIPLE ASYNCHRONOUS DATA UNIT
SINGLE UNIT ASSEMBLY (8 ADU PORTS)
W2 - BUILDING WIRING ( 25-PAIR CABLE)
C10 - 25-PAIR...

Page 127

INSTALLATION
INSTALL CUSTOMER’S SAT
The SAT can be connected through the SIP to the CPU/Memory CP by any
one of the following methods:
l On-premises nonswitched connection (no ADU required if the SAT is
plugged into the system AC outlet)
l On-premises switched connection
l Off-premises nonswitched connection
l Off-premises switched connection.
SMDR equipment can also be connected by any of the four methods listed
above.The DTU can be connected only by the on-premises nonswitched
connection.
Nonswitched...

Page 128

INSTALLATION
LEGEND :
ZTN129-CPU/MEMORY CP
C1-MODULAR CORD (D8W-87)
C2 -OCTOPUS CABLE (WP90780)
355A ADAPTER -RS-232 PLUG TO MODULAR JACK
355AF ADAPTER -RS-232 RECEPTACLE TO MODULAR JACK
* PERIPHERAL EQUIPMENT
l SYSTEM ADMINISTRATION TERMINAL (LEG 1 OF OCTOPUS CABLE)
l DIGITAL TAPE UNIT (LEG 3 OF OCTOPUS CABLE)
l SMDR OUTPUT DEVICE (LEG 2 OF OCTOPUS CABLE)
Figure 2-45.Nonswitched Connection of Peripheral Equipment Plugged
into System AC Outlet
2-103 

Page 129

Nonswitched
See Figure 2-46.
Connection of Equipment
Note:Figure 2-46 shows an Z210A1 SIP Adapter to provide the
building wiring termination.An 858A Adapter can also be
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
used.
Connect the RS-232C plug on the peripheral
232C port on a Z3A1 or Z3A4 ADU. 
Always
other fasteners on this connection.equipment to the RS-
tighten the screws or
Connect the ADU to the building wiring with a D8W-87 modular
telephone cord.
At the SIP, connect the building wiring termination to an...

Page 130

INSTALLATION
LEGEND :
B1–TYPICAL -103A CONNECTING BLOCK
C1-MODULAR CORD (D8W-87)
C2 -OCTOPUS CABLE (WP90780)
C3-EIA CROSSOVER CABLE (P17U-87)
C4 -MODULAR RECEPTACLE TO MODULAR PLUG ADU CROSSOVER (D8AM-87)
C7-MODULAR POWER CORD (D6AP-87)
W1-INSIDE BUILDING WIRING CABLE
248B ADAPTER-ALLOWS MODULAR JACK CONNECTION FROM 2012D TRANSFORMER
355AF ADAPTER RS-232 RECEPTACLE TO MODULAR JACK
2012D TRANSFORMER -
15-18V AC TRANSFORMER
Z3A1 ADU -EQUIPPED WITH A 3-FOOT PLUG-ENDED EIA CORD
Z3A4 ADU -EQUIPPED WITH A...