INSTALLATION Connection to TN763 Auxiliary Trunk CP (278A Adapter Required) A 278A Adapter is required to connect paging equipment to a TN763 Auxiliary Trunk CP (Figure 2-56) when the following conditions l Paging equipment is not FCC registered. l Paging equipment requires a contact closure Connect as shown in Figure 2-56, following the steps 1. 2. 3. 4.Connect the CP to a 66-type block, using Use kit-of-parts D-1 81524 (PEC 6251 1). Note:The 66-block provides a 3-pairexist: for proper operation....
Page 152
INSTALLATION Loudspeaker System Cross Connect Field Red 103A or Wall Jack Green Line CordB25A or A25D Auxiliary Cabinet or Wall Field T 25-Pair F Conn.on ED- 1E443- 10 PanelT R909A/B Universal Coupler 25-PairF Conn.on ED- 1E443- 10 Panel PG1/BZ1 BSY1/BY1 BSY2/BY2 PG2/BZ2 CMS2/M2 CMS1/M1 Music Source-48 V DC Power SupplyPWR GRD +/-9.5-60V dc Power Supply Port Cabinet * Replaces: 36A Voice Coupler 89A Control Unit 27BA Adapter TN763 Circuit Pack Figure 2-55a. Loudspeaker Paging with Background Music...
Page 154
INSTALLATION 5. 6. 7. 8. 9. 10. 11. Set switch to NORMAL position. Using a D4BY (single-ended) modular cord, connect D-181321 kit of parts (Figure 2-56) to a KS-22911, L2 power supply (-48V dc). Connect terminals -V and GRD on 278A adapter to D-kit. If background music is desired, connect terminals Ml and M2 on the 278A Adapter to the customer-provided music source. Connect the 278A adapter to a 103A connecting block, using 4-pair inside wiring cable.Make the following connections: 278A Term.103A Term....
Page 155
INSTALLATION LEGEND : TN763 - AUXILIARY A- B1 - C5 - C6 - P1 - W1 - 278A SINGLE-ENDED TRUNK CP 25 PAIR CONNECTOR CABLE (A25D) TYPICAL -103A CONNECTING BLOCK MODULAR CORD (D4BU-87) SINGLE-ENDED MODULAR CORD KS-22911, L2, POWER SUPPLY, -48 VOLT DC INSIDE WIRING CABLE (4-PAIR) ADAPTER -REQUIRES –24 VOLT ZENER DIODE KIT OF PARTS NOTES : 1. APPARATUS CODE D-181523 INCLUDES 66E3-25 BLOCK CONNECTOR AND CABLE B25A 15/DE. 2. APPARATUS CODE D-181524 INCLUDES C6, P1, 278A ADAPTER AND ZENER KIT. Figure 2-56.Paging...
Page 156
Figure 2-57.278A Adaptor Plug Positions for Connecting TN763 Circuit Pack to Paging System 2-127
Page 157
INSTALLATION Connection to ZTN76 or ZTN77 CP PagePac 20 system with ZoneMate 9/39 and Common Control Unit (CCU) provides up to nine/thirty-nine paging zones and multizone groups. To connect a PagePac 20 system, make connections using the following steps (Figure 2-58): 1. 2. 3. 4. 5. 6. 7. Place the PagePac amplifier on the ZoneMate and the CCU. Connect the three units as follows: a.Plug the cord attached to the CCU into the modular jack on the PagePac system. b. Connect the 25-pin cable between the...
Page 158
INSTALLATION LEGEND : ZTN76 - ZTN77 - A- B1 - C5 - W1 -GROUND START C’ LOOP START C’ 3 TO 1 SPLITTER CABLE (WP-90929,L1) TYPICAL- 103A CONNECTING BLOCK MODULAR CORD (D4BU-87) INSIDE WIRING CABLE (4-PAIR) Figure 2-58.PagePac 20 System Connection to ZTN76 or ZTN77 Circuit Pack 2-129
Page 159
INSTALLATION Customer-provided paging equipment can also be connected to ZTN76 or ZTlN77 CO trunk CPs. Connection to the system is made through the TAE appearance of the Tip/Ring pair of the CO trunk CP (See Appendix A for connection details). A paging equipment interface kit D-181900 consisting of a Universal Telephone Access Module (UPAM) and a -48 VDC power supply, PRS-48, is required unless all of the following conditions exist: l Paging equipment is FCC registered. l Paging equipment does not...
Page 160
INSTALLATION LEGEND : ZTN76- GROUND START CP ZTN77- LOOP START CP A-3 TO 1 SPLITTER CABLE (WP-90929,L1) UPAM -UNIVERSAL TELEPHONE (PAGING) ACCESS MODULE P1- PRS-48 POWER SUPPLY W1- INSIDE WIRING CABLE (4-PAIR) NOTES : 1. APPARATUS CODE D-181523 INCLUDES 66E3-25 BLOCK CONNECTOR AND CABLE B25A 15/DE. 2. APPARATUS CODE 0-181900 INCLUDES UPAM AND PRS-48 POWER SUPPLY. D-181900 IS REQUIRED UNLESS ALL OF THE FOLLOWING CONDITIONS EXIST: l PAGING EQUIPMENT IS FCC REGISTERED l PAGING EQUIPMENT DOES NOT REQUIRE A...