INSTALLATION Adapters The adapters shown in Figure 2-3 are used at the SIP. Z210A2 or 858A Adapters These adapters connect the building wiring (station runs) to the station port circuit packs (CPs) located in the system cabinets (through octopus cables). As many as 40 of these adapters may be required for a maximum size system, Any combination of the adapters can be used, depending upon the type of building wiring.The port side of the adapters consists of six 8-pin modular jacks. The station side of the...
Page 34
INSTALLATION Fanning Strip The 50A Fanning Strip (Figure 2-4) is a metal panel with positions to hold 16 octopus (switch) cables.The bundled portion of the octopus cable is anchored at the fanning strip. The eight octopus cable cords hang free. One fanning strip is required for 1-cabinet systems. Two fanning strips are required for 2- or 3-cabinet systems. NOTE : 9“ WIDE, 8-1/2” WHEN FLANGES ARE OVERLAPPED MOUNTING CENTERS Figure 2-4. 50A Fanning Strip 2-10
Page 35
INSTALLATION Cables Splitter Cables The splitter cables (Figure 2-5) connect trunk circuits from the 700A jacks to the system cabinets or 10B ETU (3:1 only). 3:1 Splitter Cable (WP90929, L1) This cable connects the twenty-four 1-pair trunk circuits on a 700A jack to three 8-port trunk circuit packs (loop start, ground start, or DID). The connection may be either director through a are male. 2:1 Splitter Cable (WP90929, L3) 10B ETU. Al 25-pair ribbon connectors on the cable This cable connects eight...
Page 36
INSTALLATION Octopus Cables Octopus cables (Figure 2-6) connect the station port and CPU/Memory circuit packs to the SIP adapters. Each cable consists of a 25-pair male connector that connects to the switch cabinet and eight modular plugs that connect to the SIP adapters. These cables are provided with all system cabinets. Figure 2-6.Octopus Cable 8536 Adapter Cable The 853B Adapter Cable (104305834) connects two octopus cables to a 16-port TN746B Analog Line circuit pack. As shown on Figure 2-6a, each...
Page 37
INSTALLATION connector and a KS23146,L3 50-pin male connector. To connect a DS1 interface circuit pack to a 551-type Unit (CSU), field terminate the 15-pin plug. To connect DS1 tie trunks on co-located System 25s, 50-pin male connector (see Figure 2-1 9). Customer Service field terminate the l C6E connector cable (comcode 104307 434)—1 00-foot long shielded cable equipped with a 50-pin male connector on one end and a 50-pin female connector on the other end. This cable is used as an “extension” cable...
Page 38
INSTALLATION AT&T CAR 1 CABLELABELS CAB1 SLOT1 CAB1 SLOT1 CAB1 SLOT2 CAB1 SLOT2 CABl SLOT3CAB1 SLOT3 CAB1 SLOT4CAB1 SLOT4 CAB1 SLOT5CAB1 SLOT5 CAB1SLOT6CAB1 SLOT6 CAB1 SLOT7CAB1 SLOT7 CAB1 SLOT8 CAB1SLOT8 CABl SLOT9CAB1SLOT9 CAB1 SLOT10CAB1 SLOT10 CAB1 SLOT11CAB1 SLOT11 CAB1 SLOT12 CAB1 SLOT12 CAB1 SLOTCAB1 SLOT CAB1 SLOTCAB1SLOT CAB1 SLOT CAB1 SLOT CAB 1 BLUE CAB 2 - ORANGE CAB 3 - GREEN CALLAT&TPROCESSOR OCTOPUS CABLELABELS SYSTEMSYSTEM ADMINADMIN TERMTERM SMDRSMDR DIGITALDIGITAL TAPETAPE UNITUNIT...
Page 39
INSTALLATION Symbols Used in Figures Modular jacks are shown by the triangle symbol. The 25-pair connectors are indicated by shaded blocks. Generally, only one leg of an octopus cable is shown. Unterminated wiring requiring cut down or other termination does not show symbolic designations.The 103A Connecting Block is a typical modular wall jack that provides cut-down connections for building (station) wiring and a modular jack for connection to terminal equipment. 2-15
Page 40
INSTALLATION PREINSTALLATION REQUIREMENTS The AT&T System 25 Reference Manual (555-540-200) provides a complete listing of System 25 equipment location requirements. Before installation begins, check the items described in this section. Caution:System 25 cross connect hardware must be located in a restricted access area only. Table and Backboard Verify that an equipment table and cross-connect backboard are installed. (See Figure 2-8 for a sample layout.) The cross-connect backboard is a 48- inch by...