Page 191
TABLE 16-20 High Density Circuit Administration (Menu=3) ACTION DESCRIPTIONDATA 1 Board type[746=TN746/767=TN767] 2Error reporting enable[1=enable/0=disable] 3Line compensation [Select 1-5] 4Zero code compression[0=ZCS/1=B8ZS] 5Framing mode [0=D4/1=ESF] 6Signaling mode[0=Robbed bit/1=Common Channel] 8Red alarm activation time [0=3 sec./1=10 sec.] TABLE 16-21 System Administration (Menu=4) ACTIONDESCRIPTIONDATA 3 Assign the number of rings before[Number of rings; 5] unanswered calls extended by Attendant...
Page 192
TABLE 16-21 System Administration (Menu=4) (continued) ACTIONDESCRIPTIONDATA 34Toll restrict calls made over inter-PBX[1-9; 0 for none] trunks (805) starting with one digit 35Specify the number of digits in the IXC[0 = 5 digits, code1 = 5 or 7 digits, 2 = 7 digits] 36Identify the INPA status for toll restriction[ 0= non-INPA, checking1 = INPA] 37Specify type of dialing plan for Home Area[0= 7-digit dialing, Code calls 1 = 10-digit dialing] 38Specify the number of digits used for[0 = 13 digits,...
Page 193
TABLE 16-21 System Administration (Menu=4) (continued) ACTIONDESCRIPTIONDATA 78Change/remove display for unassigned[“11 characters or less” DID numbers (up to 11 printable ASCIIor “ “ to remove; characters)‘NO DID IN’] 80Maintenance-busy for TIE trunks[0=enable/1=disable] 81Switched Loop Attendant system: Audible[1=Y/0=N] tone at expiration of hold timer? 83Switched Loop Attendant system: Length[10-255; 20] of hold timer (seconds) 84Switched Loop Attendant system: DID[PDC] access code to receive “0”...
Page 194
TABLE 16-21 System Administration (Menu=4) (continued) ACTIONDESCRIPTIONDATA 100 For Callback Queuing: Enter the[0 64; 64] maximum queue size for outgoing facilities: 101 For Callback Queuing: Enter the maximum[0 64; 64] queue size for internal facilities: 102 For Callback Queuing: Enter the minimum[0-120; 30] time (in seconds) between callback retries for internal facilities 103 For Callback Queuing: Enter the minimum[0-120; 30] time (in seconds) between callback retries for outgoing facilities 110 For...
Page 195
TABLE 16-22 Standard Call Type Defaults FOR SWITCHED LOOP SYSTEMS ONLY DEFAULTDEFAULT CALL TYPE CODEPRIORITYATTENDANT (Action 91)(Action 92)(Action 93) Dial Attendant (0)140 Call Following - Logged into SLAC24 NA Non logged in FPDC 34 0 Unassigned DID44 0 Attendant DID access code 54 0 PDC of Attendant 64NA Coverage701-7324 0 Returning 84 0 TABLE 16-23 Message-Center-Like Call-Type Defaults (effect of Action 90) FOR SWITCHED LOOP SYSTEMS ONLY DEFAULT ASSIGNED CALL TYPECODEPRIORITYATTENDANT (Action...
Page 196
TABLE 16-24 FPDC Administration (Menu=5) ACTIONDESCRIPTIONDATA 1 List active FPDCs 2 Add an FPDC[FPDC to be added] 3Delete an FPDC[FPDC to be deleted] 4 Enter existing FPDC to be named[FPDC] 5Assign/remove Display ID from[“11 characters or FPDC selected with Action 4less”, or “ ” to remove] TABLE 16-25 Direct Group Calling Administration (Menu=6) ACTIONDESCRIPTIONDATA 1 2 3 11 12 13 14 20 21 51 52 53Assign a DGC access code (0 to delete an existing DGC access code) For data DGC groups only: Disable DGC...
Page 197
TABLE 16-27 Searches: Action Items (Menu=8) ACTIONDESCRIPTIONDATA 1Search for PDCs of Coverage senders[1] 2 Coverage receiver group[1-32 or 101-132 if DGC coverage group] 1 Search for stations covering a specified group [2] 2Coverage group[1-32] 1 Search for PDC of Coverage (individual) receivers [3] 2 PDC of covered station [PDC] 1 Search for PDC having an auto-intercom, message [4] waiting, manual signaling, or data button 2PDC of pointed-to station [PDC] 1 Search for PDCs that hunt to a specified...
Page 198
TABLE 16-27 Searches: Action Items (Menu=8) (continued) ACTIONDESCRIPTIONDATA 1Search for port location of external alert[19] 2PDC of station with external alert[PDC] 1Search for button location on a station[20] 2PDC of station with buttons[PDC] 3Button function code (see “Action 101” column of[1-42] Table 16-3) 1Search for area code assigned to specified ARS[21] pattern 2Pattern number or wildcard character 1Search for the DDC that can dial for a station or[22] data port. 2Enter PDC/DDC being “dialed...
Page 199
TABLE 16-28 Board Type—Wildcard Representation CATEGORY: BOARD DESCRIPTION:DATA: Empty Empty Slot (Searches 15& 17 only)0 Station Single-line Voice Terminal or Special Port2.. MERLIN CS Voice Terminal (ATL) or Attendant 3.. MET Voice Terminal4.. Trunk Ground Start or Paging7.. Loop Start or Paging8.. DID9.. TIE10.. Special Touch Tone Receiver11.. Paging13.. Selector Consoles16.. Pooled Modem19.. Tone Detector Dial Dictation21.. 22.. Data Data Ports18.. 16-36 Command ReferenceNovember 1995
Page 200
TABLE 16-29 Port/Board Type—Specific Representation CATEGORY: DESCRIPTION: DATA: Voice Station SINGLE-LINE VOICE TERMINALS: Without message waiting indicator 201 With message waiting indicator202 MERLIN CS (ATL) VOICE TERMINALS: 5-Button, Z7302H01 302 5-Button Cordless ATL, Z7312H01-003303 10-Button, Z7303H01304 10-Button Hands-Free Answer on Intercom, Z7309H01303 10-Button Built-in-Speakerphone, Z7313H01A303 22-Button Built-in-Speakerphone, Z7314H01A312 34-Button, Z7305H01 307* 34-Button Deluxe,...