Home > ATT > Communications System > ATT System 25 Advanced Administration User Guide

ATT System 25 Advanced Administration User Guide

Here you can view all the pages of manual ATT System 25 Advanced Administration User Guide. The ATT manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 181

TABLE 16-9 MET Set Button Defaults
7 - SYS ACCESS
8 - SYS ACCESS
9 - REP DIAL
10 - REP DIAL
11 - LAST # DIALED
Message†
Drop†
Conference†
Transfer†
Hold†
†   Cannot be changed.
16-18 Command Reference 

Page 182

TABLE 16-10 PORT/PDC Administration, Data Terminals (Menu=1/2)
ACTIONDESCRIPTIONDATA
OPhysical port numberCSSPP
Enter data type code[See Table 16-10]
2
Enter DDC[1-9999; 600-704]
3Restrict dial access to CO trunk pool†
[1=Y/0=N]
4
Restrict dial access to all other trunk pools†[1=Y/0=N]
12DDC of station to hunt to next[PDC; 0 for none]
13Restrict this station from making outward[1=Y/0=N]
calls?
14Assign toll restriction class?[1-5; 0 for none]
15Assign ARS Facility Restriction Level?[0-3; 3]
21
Enter...

Page 183

TABLE 16-10 PORT/PDC Administration, Data Terminals (Menu=1/2) (continued)
ACTIONDESCRIPTIONDATA
70Allow keyboard dialing/Command Mode†[1=Y/0=N]
71Allow user configuration of data port[1=Y/0=N]
parameters.† (The default is 0 for STARLAN
CP.)
72Allow mismatch of user’s data module and
[1=Y/0=N]
data port baud rate†
73Allow characters dialed from keyboard to be[1=Y/0=N]
echoed by the data port†
74
Enter your disconnect code†[1-2 short BREAKS/
0-1 long BREAK]
75Allow call progress text messages to...

Page 184

TABLE 16-12 PORT Administration, Trunks (Menu=1)
ACTIONDESCRIPTIONDATA
OPhysical port numberCSSPP
1Enter trunk port type code[See Table 16-13]
2Enter trunk number[0001-9999; 0001-0104]
3Assign Class-of-Service code[(DID 1-4; 3)
(All other—
See Table 16-14; 8)]
4Assign pooled facility access code.[Facility access code;
(100, 101, 102)
0 if trunk not in any group
5Allow dial access[1=Y/0=N]
6Assign the trunk to a DGC group[1-32; 0 for none]
7Make this a directed night service trunk[1=Y/0=N]
8Assign night...

Page 185

TABLE 16-13 Trunk Type Codes
If the Trunk Type is:
Code:
Ground Start, CO
701†
Ground Start, WATS, FX
Ground Start, PBX/Centrex
Loop Start, CO
Loop Start, WATS, FX
Loop Start, PBX/Centrex
DID Immediate Dial
DID Wink Start
Auto-in/Auto-out
Auto-in/Immediate Dial-out
Immediate Dial-in/Auto-out
Immediate Dial-in/Immediate Dial-out
Wink Dial-in/Auto-out
Wink Dial-in/Wink Dial-out
Delay Dial-in/Auto-out
Delay Dial-in/Delay Dial-out
702
705*
801†
802
805*
901
902†
1001
1002
1003
1004
1005
1006†
1007
1008
†...

Page 186

TABLE 16-14 Trunk Class of Service (for all trunks, except DID)
TRUNK CLASS OF SERVICE
(FOR ALL TRUNKS EXCEPT DID)
COS
CODE
O
1
2
3
4
NIGHTOUTWARDINSHORT
SERVICESIGNALINGONLYDISCONNECT
TT
TT
l
TTl
TTll
5
6
7
8
9
10
11
12
13
14
15DP
DPl
DPl
DPll
lTT
lTT
l
lTTl
lTTll
lDP
lDP
l
lDPl
lDPll
TT = Touch Tone
DP = Dial-Pulse
November 1995Command Reference 16-23 

Page 187

TABLE 16-15 Port Administration, Auxiliary Equipment (Menu=1)
ACTIONDESCRIPTIONDATA
ODisplay physical port number, in the form CSSPP
1Enter special feature port type code(see Table 16-16)
1Assign external alerts[253]
2Assign associated station number[PDC of associated
station, 0 if night
service alert]
1Assign paging Interface (associated with auxiliary[1301-1303]
trunk circuit)
2Assign PDC for this zone[PDC (zone 1)
PDC (zone 2)
PDC (zone 3)
0 for none]
3Assign all-zone PDC[PDC for all-zone,
0 for...

Page 188

TABLE 16-15 Port Administration Auxiliary Equipment (Menu=1) (continued)
ACTION
DESCRIPTIONDATA
1
Assign pooled modem[1901]
1
Assign additional tone detector[2101]
1
Assign dial dictation[2201 (aux. trunk
interface); 201 (station
port interface)]
2
Assign dial dictation PDC[PDC]
1
Assign selector console[1601 or 1602]
21-27
Assign the hundreds group to this button.
TABLE 16-16 Auxiliary Equipment Port Type Codes
This table shows data values associated with Action=1 on Table 16-15.
FEATURE
TN742,...

Page 189

TABLE 16-17 Port Options
PORTS, Station/Trunk/Special Port Circuit Board Options
FOR QUALIFIED SYSTEMS TECHNICIANS ONLY†
(See Table 16-18, “Applicable Options”)
ACTIONDESCRIPTION
DATA
32
Set CO disconnect time (in 20 msec increments)[0-2540 msec; 500]
33
Set end-to-end signaling tone timing
(in 20 msec increments)
FOR TN742 AND ZTN78 ONLY:[20-2540 msec; 340]
FOR ALL OTHER BOARDS:[0-2540 msec; 60]
34
Set end-to-end signaling pause timing
in 20 msec increments)
FOR TN742 AND ZTN78 ONLY:[20-2540 msec; 100]...

Page 190

TABLE 16-18 Available Options
See WARNING for Table 16-17. In this table, a bullet indicates that the default value for that
action (shown in Table 16-17) is applicable for this circuit board.
CIRCUIT
BOARD
ZTN76
ZTN77
TN753
TN760LS Trunk
l
ll
ll
ll
l DID Trunk
TN763
TN742
ZTN78
ZTN79
TN735
ZTN85
TN748
BOARDACTION
TYPE32333435†363738
GS Trunkllll
TIE Trunklllll
AUX Trunkll
T.T. Stationlglgll
T.T. Stationlglg
ATL Station
MET Station
Svc. Ckt.
Tone Det.
ZTN131
TN767
TN767
TN767
TN767
TN767Svc. Ckt.
OPS...
Start reading ATT System 25 Advanced Administration User Guide