Page 271
Troubleshooting Troubleshooting AT&TConnect This section presents some common problems that you might encounter while using AT&TConnect. For each problem, a strategy is presented that you can follow to isolate and solve your problem. Problem 1: AT&TConnect will not run. It displays the message This application requires a serial port and terminates. This message indicates that AT&TConnect cannot find an available serial port on your system. This message will most likely appear immediately after you have...
Page 272
Troubleshooting 3.Type comcheck and press [ ENTER ¿ ]. The status of each COM port in your PC is displayed. The following is a sample of what you may see: COMCheck V1.0 (c)1993 AT&T Serial port detection program Port ----- COM1 COM2 COM3 COM4 Detected ---------- Yes Yes No No If this procedure reveals that your PC has no active COM ports or only COM1 is active (but is used by your mouse under Windows), you will need to either purchase an additional COM port for your PC or consult your PC’s hardware...
Page 273
Troubleshooting Problem 2: AT&TConnect displays its Communications Error dialog box within a few seconds after it is run This message indicates that AT&TConnect cannot communicate properly with your PassageWay adapter. This message can appear for one of the following reasons: n n n nYour PassageWay adapter is not connected properly to your PC serial port and/or your telephone. Your PassageWay adapter is not receiving power from the PARTNER system. AT&TConnect is administered to use a different serial...
Page 274
Troubleshooting AT&TConnect cannot communicate properly with your PassageWay adapter. Please follow the steps below, in order, to resolve the problem: 1. 2. 3. 4.Verify that the adapter is present and properly connected to your telephone and PC serial port. If the adapter is not present, you cannot use PassageWay to control your telephone, and you must Press the Quit button below to exit this application. Verify that the LED on the PassageWay adapter is illuminated. If not, verify that the adapter is...
Page 275
Troubleshooting You should follow the instructions provided on this dialog box to troubleshoot the problem. These instructions ask you to verify the following items: nThe PC-side and phone-side cabling associated with your PassageWay adapter is properly connected. Insure that the 7-foot phone cord is completely inserted into both the jack marked Line of your telephone and the modular jack on the PassageWay adapter. A proper connection is confirmed by a tactile click as the cord is fully inserted. Also...
Page 276
Troubleshooting COM ports, and you could erroneously administer AT&TConnect to use this same COM port. When selecting a serial port for AT&TConnect to use, you should be careful that the COM port you select is not already being used by another device in your PC. nAT&TConnect’s software-based adapter test passes. To assist you in diagnosing problems, AT&TConnect contains a built-in adapter test procedure. This test can be run directly from the Communications Error dialog box by choosing the Test button....
Page 277
Troubleshooting 9-8 Failure CodeMeaningThings to Try 111The PC and theMake sure you have PassageWayselected the proper adapter cannotCOM port in communicate overAT&TConnect. your serial port. Try replacing any RS-232 cables or adapters you are using between your PC’S COM port and the PassageWay adapter’s 25-pin connector. 121 The PC and theFollow the PassageWayinstructions for adapter cannotfailure code 111. communicate over your serial port. 131, 132, 133, orThe PC cannotTry replacing any...
Page 278
Troubleshooting 134 or 141The PassageWayTry replacing the 7- adapter cannot foot telephone communicate cable between the properly with your PassageWay telephone. adapter and your telephone. 200 and aboveA conflict or Try closing all application error has Windows occurred whichapplications except prevented AT&TConnect and AT&TConnect from Program Manager, operating your PC then try the test serial port.again. You may need to modify your autoexec.bat and config.sys files to eliminate this conflict. Problem...
Page 279
Troubleshooting If you cannot get AT&TConnect to work properly on COM3, check if another device is using COM1 at the same time. Similarly, if you cannot get AT&TConnect to work on COM4, determine if another device is using COM2 at the same time. If so, you may need to make some changes to your PC configuration to support using PassageWay on COM3 or COM4. Refer to Appendix B for more information. If you need additional assistance in setting up devices on COM3 or COM4, consult your PC hardware vendor....
Page 280
Troubleshooting Troubleshooting AT&TCall This section presents some common problems you might encounter using AT&TCall For each problem, a strategy is presented that you can follow to isolate and solve your problem. Problem 1: AT&TCall does not dial or turn on the speaker AT&TConnect must be running in order for AT&TCall to dial using your telephone. Run AT&TConnect, wait for your telephone to be initialized, and try dialing again. If AT&TConnect will not run (that is, it displays the message This...