Page 101

HARDWARE AND SOFTWARE DETERMINATIONaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
Cabinet Determination (DEFINITY Generic 1 and Generic 3)
DEFINITY Communications Systems G1 and G3 have a duplication option for the control cabinet
(that is, control circuits are duplicated).  These systems also have an option for duplicating the
expansion cabinet (that is, a second port cabinet can be added).  A DEFINITY system  is ordered
according to the need for duplication, the number of ports required, and future growth expecta-...

Page 102

aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaHARDWARE AND SOFTWARE DETERMINATION
Multi-Carrier Cabinet Configuration
A multi-carrier cabinet configuration can be selected from the following equipment arrangements.
The G3r data is given in the following table separately from the G1 and G3i data.
The G3r data has special considerations and limitations:
dThe PPN cabinet is the first cabinet and is available only in the multi-carrier cabinet.
dThe PPN cabinet supports only one port network.
dThe PPN cabinet is...

Page 103

HARDWARE AND SOFTWARE DETERMINATIONaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
Max Attribute
Carriers Port Slots* PEC for AC for DC
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
PPN With Duplication
Duplication Equipment 63201
Control A + Dup. Control B 18 (16) 6300-05A PRC03 PRC05
Control A + Dup. B + Port C 38 (36) 6300-05B PRC03 PRC05
Control A + Dup. B + Ports C, D 58 (56)...

Page 104

aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaHARDWARE AND SOFTWARE DETERMINATION
Single-Carrier Cabinet Configuration
A single-carrier cabinet configuration can be selected from the following equipment arrange-
ments.  The G3r data is given in the following table separately from the G1 and G3i data.
Note:The G3r PPN is only available as a multi-carrier cabinet.  The G3r EPN is, however,
available in single-carrier cabinets....

Page 105

HARDWARE AND SOFTWARE DETERMINATIONaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
Ordering Information
Enter the quantities of equipment to be ordered on the Order Summary Sheet which follows
(make additional copies of the sheet if needed). The sheets,  when completed, can be attached to
the order.  Use the information listed on the various tables in the manual to complete the entries.
To ensure all equipment and facilities are ordered, complete the following checklist.
Are the following pieces of equipment/facilities...

Page 106

aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaHARDWARE AND SOFTWARE DETERMINATION
ORDER SUMMARY SHEET
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
Price
Element
Code
(PEC) Description Quantity
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb...

Page 107

aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaENVIRONMENTAL REQUIREMENTS
ENVIRONMENTAL REQUIREMENTS
General
This section provides information about the floor and wall space required for system  and associ-
ated peripheral equipment installed in the equipment room.  Specifications for temperature, humi-
dity, air purity, and lighting levels are also included.
Floor Plans and Layouts
Floor plan arrangements will vary depending on the size and shape of the equipment room and
the amount of growth...

Page 108

ENVIRONMENTAL REQUIREMENTSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
Earthquake Protection
When earthquake or disaster bracing is required by law, or when local engineering feels that
bracing is necessary, the system cabinet can be bolted to the floor.  Figure 14 shows the zones
in the North American continent where bracing may be desirable.
Note:A greater susceptibility of an area to earthquakes is indicated by a higher number in
Figure 14.  In the United States, 0 represents the lowest susceptibility...

Page 109

aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaENVIRONMENTAL REQUIREMENTS
PRINTER (OPTIONAL)MANAGER ITERMINALPROCESSOR PORTNETWORKCABINET(S)(FRONT)CABLE SLACKMANAGER(NOTE  6)CROSS- CONNECTFIELDCHAIR NOTES 3 AND 4TRUNK/AUXILIARYFIELD  (NOTE  5)W ALLNOTES:POWER OUTLETS SHOULD BE LOCATED OUTSIDE THE CROSS-CONNECT FIELD AREA.POWER OUTLET(S) MUST  NOT  BE  UNDER SWITCH CONTROL AND  MUST  NOT  BE  SHAREDWITH  OTHER  EQUIPMENT.PROCESSOR PORT NETWORK CABINETS REQUIRE A SPECIAL 120-VOLT, 60-HZ, 15-AMPOR...

Page 110

ENVIRONMENTAL REQUIREMENTSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
PRINTER (OPTIONAL)MANAGER ITERMINALCHAIR TRUNK/AUXILIARYFIELD  (NOTE  7)W ALLNOTES:POWER OUTLETS MUST NOT BE UNDER SWITCH CONTROL, MUST NOT BE SHARED WITH OTHEREQUIPMENT, AND SHOULD BE LOCATED OUTSIDE THE CROSS-CONNECT FIELD AREA.PROCESSOR PORT NETWORK CABINET REQUIRES A SPECIAL 120-VOLT, 60-HZ, 50-AMP POWEROUTLET (NEMA  5-50R  RECEPTACLE, OR EQUIVALENT).AUXILIAR Y CABINET REQUIRES A SPECIAL 120-VOLT, 60-HZ, 20-AMP POWER OUTLET(NEMA...