Page 711

Coverage Callback
Issue  3   March 1996
3-567
Coverage Callback
Feature Availability
Coverage Callback is available with all Generic 3 releases.
Description
Allows a covering user to leave a message for the principal (called party) to call 
the calling party.
Coverage Callback is activated by pressing the Cover Callback button after 
answering a coverage call.
Details of how Coverage Callback is used in conjunction with Call Coverage are 
given in the Call Coverage feature description elsewhere in this...

Page 712

Feature Descriptions
3-568Issue  3   March 1996 
Coverage Incoming Call Identification 
(ICI)
Feature Availability
Coverage Incoming Call Identification is available with all Generic 3 releases.
Description
Allows multiappearance voice terminal users without a display in a Coverage 
Answer Group to i dentify an incoming call to that group.
When an incoming call is directed to a Coverage Answer Group, the status lamp 
associated with the Coverage Answer Group button lights at group member’s 
voice...

Page 713

Customer-Provid e d Equip ment  (CPE) Alarm
Issue  3   March 1996
3-569
Customer-Provided Equipment (CPE) 
Alarm
Feature Availability
Customer-Provid e d Equip ment  (CPE)  Alarm  is  available with all Generic 3 
releases.
Description
Provides the customer with an indication that a system alarm has occurred and 
that the system has attempted to contact a preassigned service organization 
about the problem. A customer-provided device, such as a lamp or a bell, is 
used to indicate the alarm situation....

Page 714

Feature Descriptions
3-570Issue  3   March 1996 
Considerations
The CPE Alarm feature lets customers use their own equipment to indicate an 
alarm condition. This indication lets the customer know when there is a problem 
with the system and when the problem has been resolved.
Interactions
The following features interact with the CPE Alarm feature.
nPower Failure Transfer
The CPE Alarm is always activated d uring a Power Failure Transfer 
regardless of the a dministered alarm activation level....

Page 715

Customer-Provid e d Equip ment  (CPE) Alarm
Issue  3   March 1996
3-571 

Page 716

Feature Descriptions
3-572Issue  3   March 1996 
Data Call Setup
Feature Availability
Data Call Setup is available with all Generic 3 releases.
Description
Provides multi ple methods to set up a data call:
nKeyb oard dialing
nVoice terminal dialing
nHayes AT command dialing
nPermanent switched connections
nAdministered connections
nAutomatic calling unit interface (MPD and HSC)
nHotline d ialing
Typically, when a data terminal is available, keyboard dialing is more convenient 
and requires less steps;...

Page 717

Data Call Setu p
Issue  3   March 1996
3-573
button in system administration. The Data Extension button provides one-touch 
access to a data module.
The voice terminal Data Extension  buttons control the One-Button Transfer to 
Data, Return-to-Voice, and Data Call Preindication o perations for the associated 
data module. These operations are discussed below. Multiple Data Extension 
buttons can be assigned to a multiappearance voice terminal, and that voice 
terminal can set up d ata calls for other...

Page 718

Feature Descriptions
3-574Issue  3   March 1996 
called data number manually from the keyboard, and RINGING informs the user 
the called data numb er is being rung. If the data call is placed in queue, the 
message WAIT, xx IN QUEUE is received (xx represents queue position). This 
queue number is updated by the system as the call moves up in the q ueue. The 
next table lists the call progress messages.
To originate and disconnect a call using Data Terminal Dialing, the user presses 
BREAK on the...

Page 719

Data Call Setu p
Issue  3   March 1996
3-575
Single-line dialing is recommended if all  dialing information can be entered on 
one line.
Multiple-Line Dialing
Automatically invoked when a single line of dialing information is incomplete. 
Multiple-line dialing is only used with off-premises calling.
In multiple-line dialing, the DIAL: prompt follows on the next line when all of the 
dialing information of the previous line has been sent and dial tone has occurred; 
a d ditional dialing information is...

Page 720

Feature Descriptions
3-576Issue  3   March 1996 
and due to be active. The attributes of these connections are user-defined. To 
administer Administered Connections, use the “ Administered Connection” form 
via the SAT.
Once the ADM has been a dministered as one endpoint of an administered 
connection, the system waits for the scheduled time to set u p the connection. At 
the scheduled time, the system establishes the connection and maintains it for 
the length of time specified. Once the call is...