Page 721
Data Call Setu p Issue 3 March 1996 3-577 CHECK OPTIONS Placing a call Notifies calling terminal that data module options are incompatible. XX I N Q UEUECall in q ueue Current position of the user in queue. XX-indicates position. PROCESSING* Call in q ueue Notifies user when out of queue. Facility is available. TIMEOUT*Call in q ueue Notifies user when time has been exceeded. Call will b e terminated. FORWARDED* Receiving a call Equivalent to redirection notification signal. Called terminal has...
Page 722
Feature Descriptions 3-578Issue 3 March 1996 Data Call Setup for ISDN-BRI Modules Voice Terminal Dialing for ISDN-BRI Data Modules Allows ISDN-BRI voice terminal users to directly originate a d ata call. To set up a data call, the user just presses the Data button on the ISDN-BRI voice terminal, enters the desired number on the dial pad, and then presses the Data button again. The following data functions are not supported by BRI terminals: nOne b utton transfer to data nReturn-to-voice nData...
Page 723
Data Call Setu p Issue 3 March 1996 3-579 n, (pause) character may b e used to place a 1.5-second pause in dialing. (multiple, can be used). n% (mark) character may be used to indicate the following digits are for end-to-end signaling (touch-tone). This is required when the trunk is rotary. It is not required when the trunk is ‘‘touch-tone.’’ nUNDERLINE or BACKSPACE characters may be used to correct previously typ ed characters on the same line. n@ may be used to delete the entire line and start...
Page 724
Feature Descriptions 3-580Issue 3 March 1996 Call Forwarding All Calls Call Forwarding All Calls allows incoming data calls to be redirected to another extension that is designated by the user. Activation/deactivation of the feature is done either by the attendant or by the forward ing party itself through the dialing of a feature access code. Data Hotline Data Hotline is a security feature. The switch will terminate the call to a preadministered hotline d estination. If a user enters an a ddress...
Page 725
Data Call Setu p Issue 3 March 1996 3-581 Endpoint Initialization BRI en d points have to successfully complete end p oint initialization procedures in order to be fully operative. It is usually carried out at the time of installation, or as part of reconfiguration. Multipoint Configurations on BRI ports In a p assive bus multipoint c onfiguration, the system supports two BRI endpoints per port, thus doubling the capacity of the BRI circuit pack. When changing the configuration of a BRI from...
Page 726
Feature Descriptions 3-582Issue 3 March 1996 CHECK OPTIONS Placing a call Notifies calling terminal that data module options are incompatible. XX I N Q UEUECall in q ueue Current position of the user in queue. XX-indicates position. PROCESSING* Call in q ueue Notifies user when out of queue. Facility is available. TIMEOUT*Call in q ueue Notifies user when time has been exceeded. Call will b e terminated. FORWARDED* Receiving a call Equivalent to redirection notification signal. Called terminal...
Page 727
Data Call Setu p Issue 3 March 1996 3-583 Considerations All systems have Data Call Setup c a pability. This facilitates data calling by eliminating the need to dedicate a voice terminal for d ata calls. DEFINITY system Generic 3 offers the enhancement of off-premises Multiple Line Dialing. BRI has a voice to data restriction. A voice terminal cannot call a data terminal, and a data terminal cannot call a voice terminal. BRI voice terminals cannot have Data Extension buttons. Although DCP sets...
Page 728
Feature Descriptions 3-584Issue 3 March 1996 nCall Forwarding All Calls Calls incoming to a data module can be forwarded. That is, calls can be redirected to another en d point. This feature is activated using Data Terminal (Keyboard) Dialing. If the forwarded-to endpoint is an analog data endpoint, and the calling user is a d igital endpoint, modem pooling is activated automatically. nData Call Hot Line Upon going off-hook for origination, the system automatically places a call to a...
Page 729
Data Call Setu p Issue 3 March 1996 3-585 If the tone detection option is not set to ‘‘precise,’’ and a d ata c all is set up over an analog trunk, the data call setup messages desc ribing the status of the called endpoint (that is, RINGING, BUSY, TRY AGAIN, etc .), changes according to which tone d etection option is selected. Tone Detection a p plies to non-ISDN trunk lines as well. Administration Data Call Setup does not require assignment as such; however, the following related items require...
Page 730
Feature Descriptions 3-586Issue 3 March 1996 asynchronous DCE c onfiguration: an RS-366 ACU interface and a second asynchronous EIA-232D interface. In synchronous mode, the 7500B supports circuit-switched or nailed-up data communications, requires either the Multi-purpose Enhancement Board or the High-Speed Synchronous Enhancement Board, and c an only b e controlled via the front panel. In order to be configured as a synchronous DCE, the 7500B must have either the Multi-purpose Enhancement...