Page 1261

Subnet Trunkin g
Issue  3   March 1996
3-1115
Subnet Trunking
Feature Availability
This feature is available with all Generic 3 releases.
Description
Provides modification of the d ialed number so an AAR or ARS call can route over 
trunk groups that terminate in switches with different d ial plans.
Subnet Trunking provides digit insertion, deletion, pauses, and/or wait for dial 
tone in digit outpulsing, as required, to permit calls to route:
nTo or through a remote switc h
nOver tie trunks to private...

Page 1262

Feature Descriptions
3-1116Issue  3   March 1996 
With direct access to a WATS, EPSCS, CCSA, or ETN office, Subnet Trunking is 
not normally used.  The called number on these types of calls is not normally 
modified.  Subnet Trunking is need e d only if the numb er is modified or if the call 
passes through some intermediate switch, such as a main.
Calls accessing a local or FX CO directly from the terminating switch normally 
require Subnet Trunking only if access to a long-distance c arrier is other...

Page 1263

Subnet Trunkin g
Issue  3   March 1996
3-1117
O ptions”  form is set to no, the trunk is dropped and intercept tone is returned to 
the calling party.
Dial tones will also b e heard  if Network Feed b ack During Tone Detect is set to no 
on the “System Parameters Country Op tions”  form. Silence will be heard 
otherwise.
The type of outpulsing, either dial pulse (rotary) or tone, used on a call is 
specified by the trunk group selected for the  call.  In some cases, it may be 
necessary to assure that a...

Page 1264

Feature Descriptions
3-1118Issue  3   March 1996 
Interactions
Subnet Trunking is a function associated with the AAR and ARS features. 
Interactions are the same as those given for AAR and ARS.
Administration
Subnet Trunking is set by the System Manager as a part of AAR and/or ARS 
administration.  The following items require administration:
nWait — Specify the wait interval used with Subnet Trunking.
nRouting Pattern — Specify the number of digits to delete (beginning with 
the first d igit) and the...

Page 1265

Switch Based Bulletin Board
Issue  3   March 1996
3-1119
Switch Based Bulletin Board
Feature Availability
This feature requires DEFINITY Communications System G3V3 or later release 
software. (G3V3 d o es not have to be enabled on the “System-Parameters 
Customer-Options” form.) High priority messaging requires G3V4 or later release 
software.
Description
This feature provides a switch based bulletin board that allows customers and 
AT&T technical personnel to communicate with each other. A SAT user who...

Page 1266

Feature Descriptions
3-1120Issue  3   March 1996 
Bulletin Board Commands
System Commands Used to Access the Switch
Based Bulletin Board
Two c ommands change bulletin board and display bulletin board were  added 
to access the Switch Based Bulletin Board.
To enter a message into the Switch Based Bulletin Board:
1. Log in to the system with ‘‘Ad minister Features’’ p ermissions.
2. Enter the command change bulletin-board.
3. Enter your message.
4. Commit your message by pressing ‘‘Enter.’’
To display...

Page 1267

Switch Based Bulletin Board
Issue  3   March 1996
3-1121
“Associated Date” field that is populated automatically by the system each time 
the form is submitted. 
Displaying Messages on the Switch Based
Bulletin Board
While entering the display bulletin-board command into the system, the user 
can request, print, or schedule to print any message on the Switch Based 
Bulletin Board.
Considerations
User considerations:
nOnly one user can change a bulletin b oard message at a time.
nThe user must have the...

Page 1268

Feature Descriptions
3-1122Issue  3   March 1996 
Feature Initialization and Recovery
Feature recovery from a reset condition:
nThe bulletin board does not lose information during a reset level 1 or level 
2 and is read in from ta pe during reset levels 3, 4, and 5. 

Page 1269

System Measurements
Issue  3   March 1996
3-1123
System Measurements
Feature Availability
This feature is standard with all Generic 3 releases except G3vs/G3s ABP. To 
receive this feature with G3vs/G3s ABP, you must purchase the System 
Measurements O ption package or the Basic Call Center O ption Package.
NOTE:
Security Violations is always provided, even with G3vs/G3s ABP when 
neither the System Measurements Option p a ckage nor the Basic Call 
Center Option Package is purchased.
Description
Provides...

Page 1270

Feature Descriptions
3-1124Issue  3   March 1996 
nPerformance Trunk Group
nPerformance Summary
nProcessor Occupancy and Communications Links
nRoute Patterns
nSecurity Violations
nSystem Status
nTone Receiver
nTraffic Summary (G3rV1, G3V2, and later releases)
nTrunk Group Hourly (G3rV1, G3V2, and  later releases)
nTrunk Group Summary
nWideband Trunk  Group Hourly (G3V2 and later releases)
nWideband Trunk  Group  Summary (G3V2 and later releases)
All reports are on-demand reports. None are given...