Home > AOR > Communications receiver > AOR AR One Ultra Wide Band Reciever Instructions Manual

AOR AR One Ultra Wide Band Reciever Instructions Manual

Here you can view all the pages of manual AOR AR One Ultra Wide Band Reciever Instructions Manual. The AOR manuals for Communications receiver are available online for free. You can easily download all the documents as PDF.

Page 71

 70 
 
7-3-16 AF GAIN 
AG AGnnn      (nnn: 000 –255)     Default: 255 
Note: The volume control knob must be turned fully counterclockwise   
To read: AG  
Response:   AG nnn 
 
7-3-17 MANUAL GAIN (10.7 MHz AGC) 
MG 
 MGnnn      (nnn: 000 – 255)     Default: 255 
Note: Available only when the AGC is set to OFF 
To read: MG  
Response:    MG nnn 
 
7-3-18 RF GAIN 
RG 
 RGnnn      (nnn: 000 – 255)     Default: 255 
Note: The volume control knob must be turned fully 
counterclockwise 
To read: RG...

Page 72

 71 
  LM  To read: LM  
NSQm LMnnn    --- When the noise squelch is selected 
(nnn: 000 – 999) 
LSQm LMnnn    --- When the level squelch is selected 
(nnn: 000 – 999) 
m: 1    when the squelch is closed 
Response 
 
m: 0    when the squelch is opened 
 
7-3-22 AUTO SIGNAL LEVEL 
 LC              LCn   (n: 0 or 1)     
n:0    Auto Signal Level off 
n:1    Auto Signal Level on 
While n is set to 1, and the squelch is opened, a signal level and frequency data 
will be sent 
LSQm LMnnn    --- When the level...

Page 73

 72 
BLn        (n: 0 or 1)      Available when LA is set to 2 (Auto). 
n: 0    BACKLIT OFF 
BL 
 
 
n: 1    BACKLIT ON (Default) 
To read: BL 
Response:    BLn 
 
7-3-25 BACKLIT DIMMER 
LDn    (n: 0 or 1)    
n: 0    NORMAL (Default) 
 LD 
n: 1  DIMM 
To read: LD 
Response:    LDn 
 
7-3-26 LCD CONTRAST 
LV  LVnn    (nn: 00 – 31)    (Default: 12) 
To read: LV 
Response:   LVnn 
 
7-3-27 BEEP LEVEL 
BL BLn     (n: 0 – 9)       (Default: 5) 
To read: BL 
Response:   BLn 
 
7-3-28 SPEAKER SELECT 
SO SOn...

Page 74

 73 
  n: 1    ON 
To read: PO 
Response:    POn 
 
7-3-30 DELAY TIME (SCAN DELAY AND SEARCH DELAY) 
DD 
 DDn.n    (n.n: 0.0 – 9.9 second)      Default: 2.0 sec. 
        nn:  FF  (hold) 
To read: DD 
Response:  DDn.n  or  DDFF 
 
7-3-31 FREE SCAN 
SP 
 SPn.n  (n.n: 0.0 – 9.9 second)    
      n.n : 0.0    FREE SCAN OFF (Default) 
       n.n: 0.1 – 9.9 sec. 
To read: SP 
Response:  SPn.n  
 
7-3-32 SIGNAL METER DISPLAY 
SF 
 SFn   (n: 0 – 2)    
   n: 0  ANALOG DISPLAY 
   n: 1  DIGITAL DISPLAY in dBuV...

Page 75

 74 
To read: OL 
Response:   OLmm nnnnnnnnnn (10 digit) 
 
7-3-35 SIGNAL LEVEL UNIT (in dBuV) – Read only 
LU LU nnn          (-nnn – nnn) dBuV 
To read: LU 
Response:   LU nnn 
 
7-3-36 SIGNAL LEVEL UNIT (in dBm) – Read only   
LB LB nnn          (-nnn – nnn) dBm 
To read: LU 
Response:   LB nnn 
 
 
 
 
 
 
 
7-3-37 SEARCH DATA SETTING – Write only 
SE 
 SEnn       (nn: 01 – 40 )  Bank number 
SLnnnnnnnnnn (Lower Frequency) 
SUnnnnnnnnnn (Upper Frequency) 
AUn  
STnnnnnn,  MDn,  BWn,  ENn,  ATn,  AMn,...

Page 76

 75 
SR      Read search data of the current search bank 
SRnn   (nn: 01 – 40)   
Search data in search bank 1 - 40 
SRn    (n: 1 -  10) 4 
            Search data in search bank 1- 10 
SR%    Search data in all search bank 
SR 
 
  SRn SLnnnnnnnnnn Sunnnnnnnnnn AUn MDn BWn ATn AMn TTxxxxxxxx         
SRn --- (Blank) 
 
7-3-39 PASS FREQUENCY – Write only 
PW      Register a current freq. to Pass freq. 
PW 
  
PWnnnnnnnnnnnn    Register the freq. to Pass freq. 
 
7-3-40 PASS FREQUENCY LIST – Read only...

Page 77

 76 
 QS%%  
Delete all search data and pass frequencies on all search 
banks 
 
7-3-43 TRANSFER THE CURRENT SEARCH DATA TO VFO – Write only 
SVn      (n: 0 – 9)     
SV 
 
 
 
 n: 0        VFO – A 
n: 1        VFO – B 
:           : 
n:9     VFO – J (Default) 
  
7-3-44 MEMORY DATA SETTING – Write only 
MX -------- Write the current receiver data to the current bank and channel   
  
MX 
 
 
 MXmnn -- Write the current receiver data to the designated bank and 
channel 
(m: 0 – 9)    Bank number 
(nn: 00...

Page 78

 77 
n: 0      OFF GA 
 
 n: 1      ON 
To read: GA 
Response:   GAn 
 
7-3-47 SELECT MEMORY LIST – Read only 
GRnn          (nn: 00 – 99)    Memory channel on the designated bank 
GR%%    All channels  (100channels maximum) 
GRn              (n: 0 – 9 )        List of 10 channels data 
GR 
 
 
 
GR        Next 10 channels data 
[Example]:  GRnn mxx … nn   (nn: channel number)   
                             (m: memory bank) 
                             (xx: memory channel) 
 
7-3-48 DELETE MEMORY –...

Page 79

 78 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
8 SPECIFICATIONS 
Model:                  AR-ONE 
Configuration:           Triple conversion super heterodyne 
Frequency coverage:          10 KHz ~ 3.3 GHz (no gap) 
Receive mode:           AM, NFM, WFM, USB, LSB, CW, DATA 
Sensitivity:               (AM mode – 10 dB S/N,  NFM mode – 12 dB SINAD,  
CW/SSB mode – 10 dB S/N)  

Page 80

 79 
   10 ~ 40 KHz:          CW 22.3 uV 
      40 ~ 100 KHz:                  AM – 4.5 uV, CW – 1.5 uV 
      100 KHz ~ 40 MHz:        AM 2.5 uV, 2 ~ 40 MHz: AM – 1.5 uV, 
                        SSB/CW – 0.7 uV, NFM – 0.89 uV 
      40 MHz ~ 1 GHz:          AM – 0.89 uV, SSB/CW – 0.4 uV, NFM – 0.5 uV, WMF – 1.5 uV 
      1GHz ~ 2.5 GHz:          AM – 0.7 uV, SSB/CW – 0.32 uV, NFM – 0.4 uV, WFM – 1.5 uV 
      2.5 GHz ~ 3.3 GHz:      AM – 0.9 uV, SSB/CW – 0.35 uV, NFM – 0.5 uV, WFM – 1.5 uV 
IF...
Start reading AOR AR One Ultra Wide Band Reciever Instructions Manual