Home > AOR > Communications receiver > AOR AR One Ultra Wide Band Reciever Instructions Manual

AOR AR One Ultra Wide Band Reciever Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual AOR AR One Ultra Wide Band Reciever Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 212 AOR manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 70 
     
    7-3-16 AF GAIN 
    AG AGnnn      (nnn: 000 –255)     Default: 255 
    Note: The volume control knob must be turned fully counterclockwise   
    To read: AG  
    Response:   AG nnn 
     
    7-3-17 MANUAL GAIN (10.7 MHz AGC) 
    MG 
     MGnnn      (nnn: 000 – 255)     Default: 255 
    Note: Available only when the AGC is set to OFF 
    To read: MG  
    Response:    MG nnn 
     
    7-3-18 RF GAIN 
    RG 
     RGnnn      (nnn: 000 – 255)     Default: 255 
    Note: The volume control knob must be turned fully 
    counterclockwise 
    To read: RG  
    Response:    RG nnn 
     
    7-3-19 IF GAIN 
    IG IGnnn       (nnn: 000 – 255)     Default: 255 
    To read: IG  
    Response:    IG nnn 
     
    7-3-20 SQUELCH SELECT 
    SQn        (n: 0 or 1)        Default: 0 (noise squelch) 
    n=0   Noise Squelch mode 
    SQ 
     
    n=1   Level Squelch mode 
    To read: SQ  
    Response:   SQn 
     
    7-3-21 SIGNAL LEVEL  
    						
    							 71 
      LM  To read: LM  
    NSQm LMnnn    --- When the noise squelch is selected 
    (nnn: 000 – 999) 
    LSQm LMnnn    --- When the level squelch is selected 
    (nnn: 000 – 999) 
    m: 1    when the squelch is closed 
    Response 
     
    m: 0    when the squelch is opened 
     
    7-3-22 AUTO SIGNAL LEVEL 
     LC              LCn   (n: 0 or 1)     
    n:0    Auto Signal Level off 
    n:1    Auto Signal Level on 
    While n is set to 1, and the squelch is opened, a signal level and frequency data 
    will be sent 
    LSQm LMnnn    --- When the level squelch is selected 
    (nnn: 000 – 999) 
    m: 1    when the squelch is closed 
     
     
    m: 0    when the squelch is opened 
    To read: LC  
    LCn 
    SQm LCnnn RFnnnnnnnnnn 
    Response: 
     
     
     m: 0  Noise squelch mode 
    m: 1    Level squelch mode 
     
    7-3-23 AUTO BACKLIT 
    LAn    (n: 0 - 2) 
    n: 0    LAMP OFF 
    n: 1    LAMP ON (Default) 
    LA 
    n: 2    LAMP AUTO 
    (Will go off in 5 seconds after the squelch is closed) 
    To read: LA 
    Response:    LAn 
     
    7-3-24 BACKLIT ON/OFF  
    						
    							 72 
    BLn        (n: 0 or 1)      Available when LA is set to 2 (Auto). 
    n: 0    BACKLIT OFF 
    BL 
     
     
    n: 1    BACKLIT ON (Default) 
    To read: BL 
    Response:    BLn 
     
    7-3-25 BACKLIT DIMMER 
    LDn    (n: 0 or 1)    
    n: 0    NORMAL (Default) 
     LD 
    n: 1  DIMM 
    To read: LD 
    Response:    LDn 
     
    7-3-26 LCD CONTRAST 
    LV  LVnn    (nn: 00 – 31)    (Default: 12) 
    To read: LV 
    Response:   LVnn 
     
    7-3-27 BEEP LEVEL 
    BL BLn     (n: 0 – 9)       (Default: 5) 
    To read: BL 
    Response:   BLn 
     
    7-3-28 SPEAKER SELECT 
    SO SOn     (n: 0 – 3)       (Default: 3) 
    n: 0    FRONT OFF, REAR OFF 
    n: 1    REAR ON 
    n: 2    FRONT ON 
     
    n: 3    FRONT ON, REAR ON 
    To read: SO 
    Response:    SOn 
     
    7-3-29 EXTERNAL SPEAKER   
    POn    (n: 0 or 1)    
     PO 
     
    n: 0    OFF (Default)  
    						
    							 73 
      n: 1    ON 
    To read: PO 
    Response:    POn 
     
    7-3-30 DELAY TIME (SCAN DELAY AND SEARCH DELAY) 
    DD 
     DDn.n    (n.n: 0.0 – 9.9 second)      Default: 2.0 sec. 
            nn:  FF  (hold) 
    To read: DD 
    Response:  DDn.n  or  DDFF 
     
    7-3-31 FREE SCAN 
    SP 
     SPn.n  (n.n: 0.0 – 9.9 second)    
          n.n : 0.0    FREE SCAN OFF (Default) 
           n.n: 0.1 – 9.9 sec. 
    To read: SP 
    Response:  SPn.n  
     
    7-3-32 SIGNAL METER DISPLAY 
    SF 
     SFn   (n: 0 – 2)    
       n: 0  ANALOG DISPLAY 
       n: 1  DIGITAL DISPLAY in dBuV  (Default) 
           n: 2  DIGITAL DISPLAY in dBm 
    To read: SF 
    Response:  SFn  
     
    7-3-33 DUPLEX MODE 
    OF 
     OFnnx  (nn: 00 – 47)     (00: OFF) 
             x:  +  or  -  (Offset direction) 
    To read: OF 
    Response:   OF xnn   
     
    7-3-34 DUPLEX FREQUENCY 
    OL 
     OLmm nnnnnnnn00    (mm: 01 - 19) 
            nnnn…n:  Offset frequency  (in 100Hz step, 
    						
    							 74 
    To read: OL 
    Response:   OLmm nnnnnnnnnn (10 digit) 
     
    7-3-35 SIGNAL LEVEL UNIT (in dBuV) – Read only 
    LU LU nnn          (-nnn – nnn) dBuV 
    To read: LU 
    Response:   LU nnn 
     
    7-3-36 SIGNAL LEVEL UNIT (in dBm) – Read only   
    LB LB nnn          (-nnn – nnn) dBm 
    To read: LU 
    Response:   LB nnn 
     
     
     
     
     
     
     
    7-3-37 SEARCH DATA SETTING – Write only 
    SE 
     SEnn       (nn: 01 – 40 )  Bank number 
    SLnnnnnnnnnn (Lower Frequency) 
    SUnnnnnnnnnn (Upper Frequency) 
    AUn  
    STnnnnnn,  MDn,  BWn,  ENn,  ATn,  AMn,  
    ACn, ,,,, 
    TTxxxxxxxx (Enter text as needed) 
    Example: 
    SE01,  SL0124500000,  SU0123900000,  AU1,  
    ST002500,,,,,, 
    Note: Refer to individual command for details of each field 
     
    7-3-38 SEARCH DATA LIST – Read only  
    						
    							 75 
    SR      Read search data of the current search bank 
    SRnn   (nn: 01 – 40)   
    Search data in search bank 1 - 40 
    SRn    (n: 1 -  10) 4 
                Search data in search bank 1- 10 
    SR%    Search data in all search bank 
    SR 
     
      SRn SLnnnnnnnnnn Sunnnnnnnnnn AUn MDn BWn ATn AMn TTxxxxxxxx         
    SRn --- (Blank) 
     
    7-3-39 PASS FREQUENCY – Write only 
    PW      Register a current freq. to Pass freq. 
    PW 
      
    PWnnnnnnnnnnnn    Register the freq. to Pass freq. 
     
    7-3-40 PASS FREQUENCY LIST – Read only 
    PRnn    (nn: 01 – 40)  Bank number 
    PR00 nnnnnnnnnn 
    PR 
    PR01 nnnnnnnnnn 
    :      : 
    PRmm ---    (mm: 00 – 49) 
    Last channel will be 49 or blank (- - -) 
      
     
     
    7-3-41 DELETE PASS FREQUENCY – Write only 
    PDmmnn    (mm: 01 – 40) Bank number 
    (nn: 00 – 49) Pass channel 
    PD 
    PDmm%%    (mm: 01- 40) Bank number 
      Delete all pass frequencies on designated bank 
    number 
           
    7-3-42 DELETE SEARCH DATA WITH PASS FREQUENCY – Write only 
    QS QSnn      (nn: 01 – 40)  
    Delete search data and pass frequency on designated search 
    bank  
    						
    							 76 
     QS%%  
    Delete all search data and pass frequencies on all search 
    banks 
     
    7-3-43 TRANSFER THE CURRENT SEARCH DATA TO VFO – Write only 
    SVn      (n: 0 – 9)     
    SV 
     
     
     
     n: 0        VFO – A 
    n: 1        VFO – B 
    :           : 
    n:9     VFO – J (Default) 
      
    7-3-44 MEMORY DATA SETTING – Write only 
    MX -------- Write the current receiver data to the current bank and channel   
      
    MX 
     
     
     MXmnn -- Write the current receiver data to the designated bank and 
    channel 
    (m: 0 – 9)    Bank number 
    (nn: 00 – 99) Memory channel 
     [Example]:  MXmnn 
                RFnnnnnnnnnn  (Frequency) 
                AUn             
                STnnnnnn, MDn, BWn, ENn, ATn, AMn, ACn 
                GAn     
                TMxxxxxxxx 
                Note: Refer to individual commands for details of each field. 
     
     
    7-3-45 MEMORY DATA LIST – Read only 
    MAn        (n: 0 – 9)    Bank number,    Memory data between CH00 to 
    CH10 
      
    MA 
     
    MA          Memory data for bank number higher than 10 
        [Example]:      MXmnn MPn GAn RFnnnnnnnnnn AUn MDn BWn ATn AMn 
    TMxxxxxxxx 
      
    7-3-46 SELECT MEMORY ON/OFF 
      GAn    (n: 0 or 1)      Memory select On/Off  
    						
    							 77 
    n: 0      OFF GA 
     
     n: 1      ON 
    To read: GA 
    Response:   GAn 
     
    7-3-47 SELECT MEMORY LIST – Read only 
    GRnn          (nn: 00 – 99)    Memory channel on the designated bank 
    GR%%    All channels  (100channels maximum) 
    GRn              (n: 0 – 9 )        List of 10 channels data 
    GR 
     
     
     
    GR        Next 10 channels data 
    [Example]:  GRnn mxx … nn   (nn: channel number)   
                                 (m: memory bank) 
                                 (xx: memory channel) 
     
    7-3-48 DELETE MEMORY – Write only 
    MQn            (n:0 – 9 )    Bank number 
    MQn 
     
    MQ%%    All bank 
     
    7-3-49 TRANSFER MEMORY DATA TO VFO – Write only 
    MVn     (n: 0 – 9 )  
    MV 
     
     
     
     
     n: 0      VFO – A 
    n: 1      VFO – B 
    :         : 
    n: 8      VFO – I    (Default) 
    n: 9      VFO – J 
     
    7-3-50 RESET – Write only 
      RS 
     
     RS            After executing the RS command, turn off the power 
    and 
    turn back on. This initializes the flash memory. 
    (All Search data and memory data will be deleted) 
     
     
      
    						
    							 78 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    8 SPECIFICATIONS 
    Model:                  AR-ONE 
    Configuration:           Triple conversion super heterodyne 
    Frequency coverage:          10 KHz ~ 3.3 GHz (no gap) 
    Receive mode:           AM, NFM, WFM, USB, LSB, CW, DATA 
    Sensitivity:               (AM mode – 10 dB S/N,  NFM mode – 12 dB SINAD,  
    CW/SSB mode – 10 dB S/N)  
    						
    							 79 
       10 ~ 40 KHz:          CW 22.3 uV 
          40 ~ 100 KHz:                  AM – 4.5 uV, CW – 1.5 uV 
          100 KHz ~ 40 MHz:        AM 2.5 uV, 2 ~ 40 MHz: AM – 1.5 uV, 
                            SSB/CW – 0.7 uV, NFM – 0.89 uV 
          40 MHz ~ 1 GHz:          AM – 0.89 uV, SSB/CW – 0.4 uV, NFM – 0.5 uV, WMF – 1.5 uV 
          1GHz ~ 2.5 GHz:          AM – 0.7 uV, SSB/CW – 0.32 uV, NFM – 0.4 uV, WFM – 1.5 uV 
          2.5 GHz ~ 3.3 GHz:      AM – 0.9 uV, SSB/CW – 0.35 uV, NFM – 0.5 uV, WFM – 1.5 uV 
    IF frequencies:          1
    st IF: 754 MHz / 265 MHz 
                           2
    nd IF: 10.7 MHz 
                           3
    rd IF: 455 KHz 
    Frequency steps:                Standard steps:    1, 10, 50, 100, 500 Hz, 1, 2, 5, 6.25, 9, 10, 
    12.5, 
      25, 50, 100 KHz 
    Non standard steps:            Less than 1 MHz (1Hz incremental) 
    Selectivity:              BW            - 6 dB          -60 dB 
                     
    0.5 KHz       0.5 KHz >        < 2 KHz 
                          3 KHz         3KHz >           < 6 KHz 
                          6 KHz         6 KHz>           < 20 KHz 
                          8.5 KHz       8.5 KHz >         < 30 KHz 
                          16 KHz        16 KHz >         < 40 KHz 
                          30 KHz        30 KHz >         < 70 KHz 
                          100 KHz      100 KHz >         < 450 KHz 
                          200 KHz      200 KHz >         < 600 KHz 
                          300 KHz      300 KHz >         < 900 KHz 
    Spurious Sensitivity:    60 dB > 
    Adjacent Selectivity:    55 dB > 
    Dynamic Range:       90 dB > 
    Unwanted Spurious emission: < - 57 dBm 
    3
    rd IP:                 + 2 dBm > (- 1 dBm > above 2.5 GHz) 
    Frequency stability:          +/- 0.1 ppm ( -10 ~ 50 C) 
    THD:                 20 dB> ( < 10 %) 
    Audio Output:                  2.0 w (at 8 ohms, THD < 10 %) 
    Power requirement:        13.5 V DC, < 2 amp. (@ 1 w audio output) 
    Antenna impedance:   50 ohm 
    Antenna Connector:        N type 
    IF output level:        -20 dBm  (10.7 MHz or 455 KHz)  
    						