50 Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (LAMP). 6-2 Configure lamp The AR-ONE is equipped with high intensity green LEDs to illuminate the LCD and keypad when operating in areas of low level lighting. The lamp may be configured in three ways: AUTO The lamp will automatically illuminate when the keypad or main tuning dial are used. The lamp will remain illuminated for further five second after the last key push and then switch off. The lamp will also automatically illuminate while the squelch opens. ON This is default setting. The lamp will continuously illuminate the LCD and keypad. OFF The lamp remains permanently extinguished, this is useful when used in areas of high light levels. To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “LAMP” selection point. Use the main tuning dial or the right arrow key or the left arrow key to toggle the lamp between AUTO, ON and OFF. Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (DIMM). 6-3 Configure dimmer A DIMM (dimmer) function is available to dim intensity of the LEDs. This function is useful when used in areas of high light levels. The default setting of DIMM is “OFF”.
51 To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “DIMM” selection point. Use the main tuning dial or the right arrow key or the left arrow key to toggle the dimmer between ON and OFF. Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (CONTRAST). 6-4 Configure contrast The AR-ONE is equipped with variable LCD contrast which is adjustable in 32 steps to provide best visibility under different viewing angles, extremes of ambient light & temperature (and between sets due to variation). The default setting for contrast is 12. The display generally becomes too dark to read around 20 and too feint around 02. Best results are usually achieved within the range of 09 – 15. To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “CONTRAST” selection point. Use the main tuning dial or the right arrow key or the left arrow key to vary the contrast level to achieve best visibility. Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (OPENING MESSAGE). 6-5 Configure Manual AGC
52 The manual AGC function is to adjust the receiver’s AGC (Automatic Gain Control) when it is set OFF. The default setting for Manual AGC is 255, maximum gain control value. The value can be adjusted according to the receiving condition. To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “MANU AGC” selection point. Use the main tuning dial or the right arrow key or the left arrow key to vary the manual AGC level for best reception. Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (IF-GAIN). 6-6 Configure IF-GAIN (Intermediate Frequency gain)
53 The IF gain control reduces the amplification in the receiver’s IF circuits and has the effect of reducing the sensitivity of the receiver. Normally, this is performed by the AGC system, and the control is left at maximum gain, but reducing the gain can be useful to limit noise when listening to CW or SSB signals. The IF gain control is must be used if the AGC is turned off. The default setting for IF-GAIN is 255, maximum gain control value. To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “IF-GAIN” selection point. Use the main tuning dial or the right arrow key or the left arrow key to vary the IF-Gain level for best reception. Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (RF-GAIN). 6-7 Configure RF-GAIN (Radio Frequency gain) The RF gain setting switches in the attenuator or preamplifier to suite the band conditions and antenna in use. The default setting for RF-GAIN is 255, maximum gain control value. The value can be adjusted according to the receiving condition. To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “RF-GAIN” selection point. Use the main tuning dial or the right arrow key or the left arrow key to vary the RF-Gain level for best reception. Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry.
54 Or, push the down arrow key to move to the next item on the configuration menu (BPS). 6-8 Configure Remote BPS (Baud rate) The Remote BPS Set menu is used to configure the RS-232C computer control settings as it is important that they exactly match those of an associated computer connection or another AR-ONE (connected via a male 9-pin to mail 9-pin straight cable). To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “BPS SET” selection point. Use the main tuning dial or the right arrow key or the left arrow key to select the desired RS-232C baud rate between 4800bps and 9600bps. The default setting is 9600bps. Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (RMT-ID). 6-9 Configure RMT-ID (Remote ID) When multiple units are connected via remote connectors, each AR-ONE must be assigned a different ID (address). The value is adjustable between 00 ~ 99. The default value is 00. Important notice: It is extremely important to set the RMT-ID to 00 for normal operation of the RS-232C connection.
55 To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “RMT-ID” selection point. Use the main tuning dial or the right arrow key or the left arrow key to change the AR-ONE’s RS-232C identification address. Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (DELAY). 6-10 Configure DELAY (Scan delay and Search delay) This parameter affects the time, the AR-ONE will remain on active frequency in scan mode or search mode once the received signal has disappeared and the squelch has closed. This Is particularly useful for customizing how long the receiver will wait for a reply before resuming scan or search. For example, when communications are passed back and forth between a control tower / aircraft which may take a few seconds. The limits are OFF / HOLD and 0.1 to 0.9 seconds in 0.1 second increments. The default is 2.0 seconds. To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “DELAY” selection point.
56 Use the main tuning dial or the right arrow key or the left arrow key to select the desired delay parameters. 2.0s The AR-ONE will wait the specified time after the squelch closes before resuming scan or search. HOLD The AR-ONE will stop indefinitely when an active frequency is located, this is very useful when you don’t want to miss that once-in-a-lifetime transmission! OFF The AR-ONE will resume scan or search instantaneously when the squelch closes. Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (FREE). 6-11 Configure FREE (Scan free and Search free) The scan free and search free parameter determines how long the AR-ONE will remain on active frequency before resuming scan or search even though the frequency is still active. This is useful if you wish to gain a snap shot of activity without the AR-ONE being tied to a busy frequency for long periods of time (such as when monitoring active commercial repeaters etc). Scan free and search free time saves you having to manually intervene to force the scan or search process to resume and saves the need to lockout memory channels or search frequencies using the PAS S function. The limits are OFF and 0.1 to 9.9 seconds. The default setting is OFF. To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “FREE” selection point. Use the main tuning dial or the right arrow key or the left arrow key to select the desired free parameters. Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu
57 (SPEAKER). 6-12 Configure SPEAKER The AR-ONE is equipped with 2 separate speakers, one is in the main receiver unit and the another one is in the control head (Note: This function is available only when an optional separation kit is used), and a phones jack. Each speaker / head phones output can be configured under this menu. 6-12-1 Configure rear speaker To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “REAR SP ” selection point. This menu is to configure the rear speaker. Use the main tuning dial or the right arrow key or the left arrow key to select the desired rear speaker setting (ON or OFF). Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (FRONT SP). 6-12-2 Configure front speaker (Note: This function is available only when an optional separation kit is used)
58 To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “FRONT SP” selection point. This menu is to configure the front speaker. Use the main tuning dial or the right arrow key or the left arrow key to select the desired rear speaker setting (ON or OFF). Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (PHONES). 6-12-3 Configure head phones output Push the down arrow key to move the cursor to “PHONES” selection point. This menu is to configure the headphones output. Use the main tuning dial or the right arrow key or the left arrow key to select the desired head phones output setting (To access the configuration menu, push the FUNC key and then push the 7 key. ON or OFF). Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (Audio Filter). 6-13 Configure audio filters (HPF / LPF) The AR-ONE is equipped with an audio HPF (High Pass Filter) and a LPF (Low Pass Filter). 6-13-1 Configure audio HPF (high pass filter) The audio high pass filter is useful for limiting the audio bass response (allowing higher tones to pass) improving intelligibility in certain circumstances (such as low frequency whistles on AM, SSB & CW).
59 There are four available pass frequencies: 50Hz, 200Hz, 300Hz, and 400Hz. The higher the frequency the more limited the audio bandwidth. For highest fidelity for listening, select 50Hz. The filter selection can be set to automode to select the proper filter setting automatically. The default is AUTO. To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to “HPF” selection point. This menu is to configure the high pass filter. Use the main tuning dial or the right arrow key or the left arrow key to select the desired high