Page 31
30 Examples are “000” for the first channel location in memory bank “0” and “099” for the last memory channel in memory bank “0”. “415” is the location: memory bank “4” channel “15”. The data contents of memory and search banks are held in a EEPROM so that no backup battery is required for memory retention. The stored data may be quickly and easily recalled, changed or deleted using the memory recall and delete functions. Note: When the receiver is switched OFF, all VFO data will be...
Page 32
31 “3” location “25” (325) while in VFO mode with the text comment of “AIRBAND”. If a mistake is made during programming, push the ESC key to abort entry and return to VFO mode. 1) Start by selecting VFO mode then key in the frequency of 123.500 MHz, “mode and step size” are set to the default auto mode. Push the VFO key to set the AR-ONE into VFO mode. Push the 1 key. Push the 2 key. Push the 3 key. Push the . (decimal) key. Push the 5 key. Push the ENT key. 2) Then...
Page 33
32 3-3 Memory read “M.RD” Once frequency and mode data has been stored into a memory location, its retrieval is quick and simple. Let’s assume that you are going to retrieve the frequency of 123.500 MHz which has been programmed into memory “325” during an earlier example in the preceding section of this manual. Push the FUNC key and the push the SCAN key to go into memory read mode , the “M.RD ” icon appears on the top left of the LCD to confirm operation. The AR-ONE will...
Page 34
33 To recall memory channel “325”, push either the right arrow key or left arrow key to select “3” as the memory bank. Rotate the main tuning dial or pushing either the up arrow key or down arrow key to select “25”. 3-4 Deleting memory channels It is possible to over-write a memory channel with new data or delete the channel entirely. Push the FUNC key, and then push the 3 key to “MEM DELETE” menu. Push either the right arrow key or left arrow key to select the desired memory bank....
Page 35
34 SEARCH mode (covered later in this manual) automatically TUNES THE RECEIVER THROUGH ALL FREQUENCIES between two specified frequency limits looking for active frequencies. 4-1 SCAN – outline introduction During SCAN, the AR-ONE automatically recalls memory channel which contains data in numeric order and monitors it looking for activity. When an ‘active’ memory channel is located (when a signal is found and the squelch is open), the AR-ONE will temporarily stop scanning. 4-2 Starting...
Page 36
35 To e x i t f r o m SCAN mode, push the VFO key. 4-4 Select scan Select scan enables you to ‘tag’ memory channels to make a temporary list up to 50 channels in the same memory bank for scanning in a separate list called the SELECT SCAN LIST. 4-4-1 Adding select scan channels in memory read In memory read mode, push the FUNC key, and then push the 1 key to toggle the select scan tag on/off, the icon “SEL” confirms selection. 4-4-2 Starting / stopping select scan To start...
Page 37
36 To stop select scan, push the VFO key. 5 Search mode In search mode, the AR-ONE is programmed to automatically tune between two specified frequency limits looking for activity. Please refer to section 1-3 of this manual if you do not fully understand the function of SEARCH. 5-1 Search type The AR-ONE is equipped with PROGRAM SEARCH. PROGRAM SEARCH = search between user preprogrammed limits 5-1-1 Program search overview There are 40 program search banks (referred to simply...
Page 38
37 zLO (lower) start frequency zHI (upper) stop frequency zReceive mode (or set to AUTO MODE) zText comment The program search banks are identified by numbers (01 ~ 40). To help with identification, each bank may be labeled with an alphanumeric text comment. 5-2 Staring program search Presuming that data is already stored into a search bank … Push the SRCH key to start the program search process. The LCD icon “SRCH ” will be displayed and as long as the squelch is closed, the...
Page 39
38 5-2-1 Reversing the direction of search To reverse the direction of search, use the main tuning dial or the up arrow key or the down arrow key. This is useful to enable you to search back over an interesting point of the search process. 5-2-2 Forcing the search to resume If the AR-ONE stops on an unwanted busy frequency, rotate the main tuning dial knob or use the up arrow key or down arrow key to force the search process to resume from the current frequency displayed. 5-2-3 Stopping...
Page 40
39 5-4 Programming a search bank Each of the 40 search banks may be programmed with different frequency limits, receive modes, etc. as listed in section 8-1-1 of this manual. Push the FUNC key, and then push the 6 key to access the “SRCH PROG ” menu. Use the main tuning dial, or the right arrow key or the left arrow key or keypad to select the bank you wish to program or overwrite. (The down arrow key is used to move through the menu.