Home > AOR > Communications receiver > AOR AR One Ultra Wide Band Reciever Instructions Manual

AOR AR One Ultra Wide Band Reciever Instructions Manual

Here you can view all the pages of manual AOR AR One Ultra Wide Band Reciever Instructions Manual. The AOR manuals for Communications receiver are available online for free. You can easily download all the documents as PDF.

Page 61

 60 
pass filter setting (AUTO / 50Hz / 200Hz / 300 Hz or 400Hz). 
 
Push the ENT key to accept the data and return to a standard display.   
Alternatively, push the ESC key to abort entry.   
 
Or, push the down arrow key to move to the next item on the configuration menu (LPF). 
 
6-13-2 Configure audio LPF (low pass filter) 
The audio low pass filter is useful to cut off high tones (allowing low tones to pass) to 
improve intelligibility of weak signals in close proximity to adjacent interference and...

Page 62

 61 
The FM transmission in different world areas have been different defaults for de-emphasis. 
  
For example, a value of 759 is selected in Europe, the recovered audio will sound very   
muffled. 
 
The available range is as follows:      THRU, 25uS, 50uS, 75uS, and 750uS 
 
The audio de-emphasis can be set to automode to select the proper setting automatically. 
 
The default is AUTO. 
 
To access the configuration menu, push the FUNC key and then push the 7 key. 
Push the down arrow key to move the...

Page 63

 62 
keeping 
an eye on a distress frequency while scanning or searching another frequency band. 
 
Note: Depending upon the frequency and mode stored as priority, an audible click may be   
heard when the priority function is in operation. This is quite normal and is caused by the 
internal switching of circuitry necessary to accomplish the frequency change (as two 
frequencies cannot simultaneously be monitored). 
 
6-15-1 Engaging Priority channel   
Once engaged, the frequency is checked for activity...

Page 64

 63 
 
Or, push the down arrow key to move to the next item on the configuration menu (IF 
output). 
 
6-16 Configure IF output frequency 
The function enables you to tap the 2nd IF signal (10.7MHz) or the 3rd IF signal (455KHz) 
from the BNC (marked as 10.7MHz) type connector on the rear panel. The 10.7MHz of the 
2
nd IF signal is to be used with an optional SDU5500 or SDU5600 spectrum display unit for 
signal analysis. The bandwidth at 10.7 MHz is +/- 5 MHz from the center frequency (10 
MHz total)....

Page 65

 64 
The function enables you to select the reference signal of the receiver. 
The AR-ONE has built-in a stable reference oscillator, however, an external high stability 10 
MHz reference (such as off-air atomic coupled) can be accepted from the SMA connector 
(marked as 10 MHz IN) on the rear panel of the AR-ONE. 
 
Push the down arrow key to move the cursor to “REF SEL” selection point.   
  
Use the main tuning dial or the right arrow key or the left arrow key to select the desired   
reference signal...

Page 66

 65 
PARITY:       NONE 
XFLOW:       ONE 
 
A multiple command entry is only valid where specified. Where a multiple command entry is 
allowed, each command MUST be separated with a space “h20” (HEX DECIMAL). Each 
command is completed and a [CR] or [CR][LF]. Although there is no local echo, either [CR] 
or specified response should come back from the receiver after confirming the correct 
command. If no response has been gained after a short while, the receiver has failed to 
receive the command...

Page 67

 66 
To read: RX  
Response:  Memory manual mode    
MR MXmnn RFnnnnnnnnnn STnnnnnn Aun MDn BWn ATn AMn TMxxxxxxxx  
            Memory scan mode 
              MS MXmnn RFnnnnnnnnnn STnnnnnn Aun MDn BWn ATn Amn 
TMxxxxxxxx 
            Memory select mode 
              SM  MXmnn RFnnnnnnnnnn  STnnnnnn  Aun  MDn  BWn  Atn  Amn 
TMxxxxxxxx 
            Search mode 
              SSmm  RFnnnnnnnnnn  STnnnnnn  Aun  MDn  BWn  Atn  Amn 
TTxxxxxxxx 
            VFO mode 
              Vx RFnnnnnnnnnn STnnnnnn...

Page 68

 67 
To read: AU  
Response:   AUn 
 
7-3-5 OPERATION MODE 
MDn    (n: 0 - 6)              Auto mode will be disabled by this command 
n=0    FM (BW=16KHz,HPF=50Hz,LPF=3KHz,De-emphasis=750uS)   
n=1    AM (BW=6KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU) 
n=2    CW (BW=0.5KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU) 
n=3    USB    (BW=3KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU) 
n=4    LSB    (BW=3KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU) 
n=5    WFM (BW=200KHz, HPF=50Hz, LPF=12KHz, De-emphasis=75uS) 
 MD...

Page 69

 68 
n=3   400Hz  
n=F   AUTO 
To read: HP  
Response:     HPn   
 
7-3-8 LPF (Low Pass Filter) 
LPn    (n: 0 – 3 & F)        Auto mode will be disabled by this command 
n=0   3KHz 
n=1   4KHz 
n=2   6KHz 
n=3   12KHz 
 LP 
n=F   AUTO 
To read: LP  
Response:    LPn   
 
7-3-9 AGC (Automatic Gain Control) 
ACn    (n: 0 – 2)     
n=0   AGC - OFF 
n=1   AGC - FAST 
n=2   AGC - SLOW 
 AC 
 
 
 
 
n=3   AGC - MIDDLE 
To read: AC  
Response:    ACn 
 
7-3-10 DE-EMPHASIS 
EN ENn    (n: 0 – 5)            Auto...

Page 70

 69 
7-3-11 RF ATT (Attenuator) 
AT  ATn    (n: 0 –3) 
n=0     0dB 
n=1    10dB 
n=2    20dB 
 
 
 
 
n=3    AUTO 
To read: AT  
Response:    AT n 
 
7-3-12 RF AMP (Amplifier) 
AMn    (n: 0 – 2) 
n=0    RF AMP OFF 
n=1    RF AMP ON 
AM 
 
 
 
n=2    RF AMP AUTO 
To read: AM  
Response:    AMn  
 
7-3-13 BFO FREQ (Beat Frequency Oscillator Frequency) 
BF BF +/-nnnn    (nnnn: 0000 - +/- 3000Hz) 
Available in CW, LSB, USB mode only    
 
 
 Default:   CW   +800Hz 
USB  +1500Hz 
LSB   -1500Hz 
To read: BF...