Amanda Work Place Instructions Manual
Here you can view all the pages of manual Amanda Work Place Instructions Manual. The Amanda manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 71
Chapter 9: Using Serial Integration 63 11. In the SMDI section of Advanced Configuration, change smdi_port 0 To : smdi_port n where n is the number for n in step 6. 12. Verify that the smdi_type option is: smdi_type smdi Change it if necessary. 13. Modify smdi_base_port 1 if the first port on the telephone switching system is not identified as the logical port 1. For example, some telephone switching systems use the port’s extension or another logical terminal number to identify the port. The first...
Page 72
64 Installing [email protected] You must also modify your C:\AMANDA\PBX.DB\1001.PBX file to include the SMDI information. Using the Amanda Setup utility (selection 3) or the JOVE utility, verify that your integration lines are as follows. When using Setup, type 30 in the Timeout field. (30 equals 30 tenths of seconds or a total of 3 seconds.) Then enter the integration strings in the column for the extension plan your system uses. Use an entry for each string you are adding. (See “Using Character...
Page 73
Chapter 9: Using Serial Integration 65 To program the message waiting lights, use the following in the Method field of the two notification records used for Light ON and Light OFF: N OTE:The message codes above are for a 4-digit and 3-digit sta- tion plan. To modify to another digit plan, use the appropri- ate number of 0s. These examples use logical serial port 1; for other ports, the 1’s would have to be replaced. NEC 2000 and NEC 2400 This section covers serial integration for NEC 2000 and NEC...
Page 74
66 Installing [email protected] 4. You can also set smdi_pretimeout x, where x is the maximum number of sec- onds that a packet can precede the forwarded call. Start with 50, the default, but you may need to experiment to determine the best setting. On the NEC 2000, one solution provider reports that 15 is a good setting. 5. Set smdi_start option to the number that indicates the position in the integration packet sent by the telephone switching system where the field containing the port number...
Page 75
Chapter 9: Using Serial Integration 67 NOTE:To modify the above for another digit plan, use the appropriate number of r’s, b’s, s’s, e’s, and x’s. In the example, 20 is used (causing Amanda to timeout after 2 seconds if the packet has not been received) because it works for all serial integration. The number is in tenths of seconds. To program the message waiting lights for NEC 2000, use the following in the Method field of the two notification records used for Light ON and Light OFF: To program...
Page 76
68 Installing [email protected] 6. Press Y for Yes. N OTE:The smdi_max, smdi_pretimeout, smdi_start, smdi_stop, and smdi_term configuration options do not apply to AT&T System 75 and Definity-G3 telephone switching systems. You must modify your C:\AMANDA\PDX.DB\1001.PBX file to properly integrate the 7404D set information. Using either the Amanda Setup utility or the JOVE utility, verify that your integration lines are: integration 10 xxxxxxxxxxxxxx*xxxxxxxxxxxxxxxxrrr D integration 10...
Page 77
Chapter 9: Using Serial Integration 69 The *4 and #4 are the AT&T default values, often left as the standard, but fully configurable. Watch out for dialplan conflicts if you change them because the conflicts can slow down system operation if a needed wait for dial timeout (that is, a four-digit speedial code) has the same first few digits as the message waiting light feature. Ericsson MD-110 This section covers serial integration for the Ericsson MD-110 system. To set configuration options for serial...
Page 78
70 Installing [email protected] Use an entry for each string you are adding. (See “Using Character Codes” on page 32) for more information about the codes such as rrr or rrrr.) If you are using the JOVE utility, the integration timeout precedes each integration string as follows. This example is only for 4-digit station plans. N OTE:The number of x’s in the above strings is equal to the value of smdi_stop, while the number of r ’s, e ’s, b ’s, and s ’s is equal to the value of smdi_start. To modify...
Page 79
Chapter 9: Using Serial Integration 71 To program the message waiting lights for NEC 2000, use the following in the Method field of the two notification records used for Light ON and Light OFF: \B represents Ctrl+B, the start of transmission (STX) character. %E should be the same number of digits and smdi_start specifies. N OTE:These examples uses logical serial port 3; for other ports, the 3’s would have to be replaced. Generic This section covers a generic serial integration. It is designed for any...
Page 80
72 Installing [email protected] 8. You must set smdi_term n, where n is the termination character set (if there is one). Leave this option empty if the packets are terminated only by receiving smdi_max characters. 9. You can also set smdi_delay n, where n is the number of tenths of seconds that Amanda waits after the call is answered before looking for integration information. This allows more than one packet to be sent to a port per telephone call. Amanda uses the last (most recent) packet. The...