Amanda Work Group Installation Manual
Here you can view all the pages of manual Amanda Work Group Installation Manual. The Amanda manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 151
Chapter 12: Using Serial Integration 139 The first port may be extension 241, with the second port 242, etc. These numbers must be consecutive. For example, if the first or base port is 241, you use smdi_base_port 241. 14. You can also set smdi_pretimeout n, where n is the maximum number of seconds that an SMDI packet can precede the forwarded call. The default is 50. 15. You can also set smdi_delay n, where n is the number of tenths of seconds that Amanda waits after the call is answered before...
Page 152
140 Installing [email protected]/DOS If you are using the JOVE utility, the integration timeout precedes each integration string as follows. This example is only for 4-digit station plans. N OTE:To modify the above for another digit plan, use the appro- priate number of rs, bs, ss, es, and xs. Also, while 30 is used in the example (causing Amanda to timeout after 3 seconds if the packet has not been received), you may use some other number. The number is in tenths of seconds. To program the message...
Page 153
Chapter 12: Using Serial Integration 141 NOTE:The message codes above are for a 4-digit and 3-digit sta- tion plan. To modify to another digit plan, use the appropri- ate number of 0s. These examples use logical serial port 1; for other ports, the 1’s would have to be replaced. NEC 2000 and NEC 2400 This section covers serial integration for NEC 2000 and NEC 2400 systems. To set configuration options for serial integration on NEC 2000 or NEC 2400: 1. Follow steps 1 through 11 in the Bellcore Standard...
Page 154
142 Installing [email protected]/DOS 6. Set the smdi_stop option to the number that indicates the position in the integration packet sent by the telephone switching system where the field containing the port number ends. Start counting positions in the packet with the number 1. The default is 11. smdi_stop 11 7. You can also set smdi_delay x, where x is a number of tenths of sec- onds. Amanda waits that long after the call is answered before looking for integration information. This allows more than...
Page 155
Chapter 12: Using Serial Integration 143 If you are using the JOVE utility, the integration timeout precedes each integration string as follows. This example is only for 4-digit station plans. N OTE:To modify the above for another digit plan, use the appro- priate number of r’s, b’s, s’s, e’s, and x’s. In the example, 20 is used (causing Amanda to timeout after 2 seconds if the packet has not been received) because it works for all serial integration. The number is in tenths of seconds. To program...
Page 156
144 Installing [email protected]/DOS AT&T System 75 or Definity-G3 If you use AT&T System 75 or Definity-G3 (smdi_type s75), call Amanda Company customer support team for more information. Call to be faxed Technical Note 14, “Serial Integration for System 75 and Definity-G3.” To set configuration options for use with System 75 and Definity-G3: 1. Follow steps 1 through 11 in the Bellcore Standard SDMI procedure “To modify configuration options for use with Bellcore Standard SMDI:” in the “Bellcore...
Page 157
Chapter 12: Using Serial Integration 145 You must modify your C:\AMANDA\PDX.DB\1001.PBX file to properly integrate the 7404D set information. Using either the Amanda Setup utility or the JOVE utility, verify that your integration lines are: integration 10 xxxxxxxxxxxxxx*xxxxxxxxxxxxxxxxrrr D integration 10 xxxxxxxxxxxxsssxxxxxxxxxxxxxxxxrrr D integration 10 xxxxxxxxxxxxxx*xxxxAxxxxxxxxxxxrrr C integration 10 xxxxxxxxxxxxeeexxxxAxxxxxxxxxxxxxx C integration 10 xxxxxxxxxxxxxx*xxxxxxxxxxxxxxxxbbb...
Page 158
146 Installing [email protected]/DOS Mailbox 990 is the default Company Greeting mailbox. If you have redefined the Company Greeting mailbox for any of the ports, use that mailbox instead of 990. N OTE:The examples use %U (for mailbox), but you may prefer %E (for Extension field) or %V (for Variable field). You can use %E when the Extension field contains only the ex- tension number. (For example, if the Extension field con- tains an H for a blind transfer or starts with a @, %E is unusable.) You...
Page 159
Chapter 12: Using Serial Integration 147 3. Modify smdi_base_port 1 if the first port on the telephone switch- ing system is not identified as the logical port 1. For example, some tele- phone switching systems use the port’s extension or another logical terminal number to identify the port. The first port may be extension 241, with the second port 242, etc. These numbers must be consecu- tive. For example, if the first or base port is 241, you use smdi_base_port 241. 4. You can also set...
Page 160
148 Installing [email protected]/DOS Use an entry for each string you are adding. (See “Using Character Codes” on page 82 for more information about the codes such as rrr or rrrr.) If you are using the JOVE utility, the integration timeout precedes each integration string as follows. This example is only for 4-digit station plans. 4-Digit Station Plan3-Digit Station Plan Forward no answer:80rrrrxx80rrrxx Direct station access:81eeeexx81eeexx Direct station access:82eeeexx82eeexx Forward no...