Page 151

Chapter 12: Using Serial Integration 139
The first port may be extension 241, with the second port 242, etc. 
These numbers must be consecutive. For example, if the first or base 
port is 241, you use smdi_base_port 241.
14. You can also set smdi_pretimeout
 n, where n is the maximum 
number of seconds that an SMDI packet can precede the forwarded call. 
The default is 50.
15. You can also set smdi_delay
 n, where n is the number of tenths of 
seconds that Amanda waits after the call is answered before...

Page 152

140 Installing [email protected]/DOS
If you are using the JOVE utility, the integration timeout precedes each 
integration string as follows. This example is only for 4-digit station plans.
N
OTE:To modify the above for another digit plan, use the appro-
priate number of rs, bs, ss, es, and xs. Also, while 30 is 
used in the example (causing Amanda to timeout after 3 
seconds if the packet has not been received), you may use 
some other number. The number is in tenths of seconds.
To program the message...

Page 153

Chapter 12: Using Serial Integration 141
NOTE:The message codes above are for a 4-digit and 3-digit sta-
tion plan. To modify to another digit plan, use the appropri-
ate number of 0s. These examples use 
logical serial port 1; 
for other ports, the 1’s would have to be replaced.
NEC 2000 and NEC 2400
This section covers serial integration for NEC 2000 and NEC 2400 systems.
To set configuration options for serial integration on NEC 2000 or NEC 
2400:
1. Follow steps 1 through 11 in the Bellcore Standard...

Page 154

142 Installing [email protected]/DOS
6. Set the smdi_stop option to the number that indicates the position in the 
integration packet sent by the telephone switching system where the 
field containing the port number ends. Start counting positions in the 
packet with the number 1. The default is 11.
smdi_stop 11
7. You can also set smdi_delay
 x, where x is a number of tenths of sec-
onds. Amanda waits that long after the call is answered before looking 
for integration information. This allows more than...

Page 155

Chapter 12: Using Serial Integration 143
If you are using the JOVE utility, the integration timeout precedes each 
integration string as follows. This example is only for 4-digit station plans.
N
OTE:To modify the above for another digit plan, use the appro-
priate number of r’s, b’s, s’s, e’s, and x’s. In the example, 
20 is used (causing Amanda to timeout after 2 seconds if 
the packet has not been received) because it works for all 
serial integration. The number is in tenths of seconds.
To program...

Page 156

144 Installing [email protected]/DOS
AT&T System 75 or Definity-G3
If you use AT&T System 75 or Definity-G3 (smdi_type s75), call Amanda 
Company customer support team for more information. Call to be faxed 
Technical Note 14, “Serial Integration for System 75 and Definity-G3.”
To set configuration options for use with System 75 and Definity-G3:
1. Follow steps 1 through 11 in the Bellcore Standard SDMI procedure “To 
modify configuration options for use with Bellcore Standard SMDI:” in 
the “Bellcore...

Page 157

Chapter 12: Using Serial Integration 145
You must modify your C:\AMANDA\PDX.DB\1001.PBX file to properly 
integrate the 7404D set information. Using either the Amanda Setup utility 
or the JOVE utility, verify that your integration lines are:
integration 10 
xxxxxxxxxxxxxx*xxxxxxxxxxxxxxxxrrr D

integration 10 
xxxxxxxxxxxxsssxxxxxxxxxxxxxxxxrrr D

integration 10 
xxxxxxxxxxxxxx*xxxxAxxxxxxxxxxxrrr C

integration 10 
xxxxxxxxxxxxeeexxxxAxxxxxxxxxxxxxx C

integration 10 
xxxxxxxxxxxxxx*xxxxxxxxxxxxxxxxbbb...

Page 158

146 Installing [email protected]/DOS
Mailbox 990 is the default Company Greeting mailbox. If you have 
redefined the Company Greeting mailbox for any of the ports, use that 
mailbox instead of 990.
N
OTE:The examples use %U (for mailbox), but you may prefer 
%E (for Extension field) or %V (for Variable field). You 
can use %E when the Extension field contains only the ex-
tension number. (For example, if the Extension field con-
tains an H for a blind transfer or starts with a @, %E is 
unusable.) You...

Page 159

Chapter 12: Using Serial Integration 147
3. Modify smdi_base_port 1 if the first port on the telephone switch-
ing system is not identified as the logical port 1. For example, some tele-
phone switching systems use the port’s extension or another logical 
terminal number to identify the port. The first port may be extension 
241, with the second port 242, etc. These numbers must be consecu-
tive. For example, if the first or base port is 241, you use 
smdi_base_port 241.
4. You can also set...

Page 160

148 Installing [email protected]/DOS
Use an  entry for each string you are adding. (See “Using 
Character Codes” on page 82 for more information about the codes such as 
rrr or rrrr.)
If you are using the JOVE utility, the integration timeout precedes each 
integration string as follows. This example is only for 4-digit station plans.
4-Digit Station Plan3-Digit Station Plan
Forward no answer:80rrrrxx80rrrxx
Direct station access:81eeeexx81eeexx
Direct station access:82eeeexx82eeexx
Forward no...