Page 41

 # 


UEC port communication speed (former name: MODE 46) 
Default: 3   
Setting: 1   9600 bps 
Setting: 2   19200 bps 
Setting: 3   38400 bps 
]Function^ 
Note:  This is to determine the communication speed between UEC and PC.    This is not the 
communication speed of the data output port in rear of UEC.     
Note:      Switch off UEC after you change the setting value of the PC port communication 
speed.    Setting value will not be changed unless UEC is once switched off. 



Waveform...

Page 42

 #  
TIMER Setting

First screen (1/2)












JUDGMENT DELAY (Judgment delay timer (former name: TIMER 1) 
Default: 300 [msec]   
Setting range: 100 – 9999 [msec] 
]Function^ 
CThis is to set time interval how long UEC delays judgment output after one fastening has been 
completed.     
CUse this timer as the torque measurement end point when UEC is in control operation.     
CTake torque spike after CUT into your consideration to determine length of this timer.   
Guideline of...

Page 43

 # 
FASTENING OK (
Fastening OK signal output timer (former name: TIMER 4) 
Default: 9999 
Setting range: 0 – 9999 [msec]   
]Function^ 
CThis is to determine the fastening OK signal output duration time from output terminal TORQUE OK.   
Not necessary to set up this timer usually.     
CUEC ceases to send the TORQUE OK output after the next tightening is made, even if this timer is 
on.   
CSet up this timer only when duration of output signal affects external PLC or circuit. 
CSet 0, and UEC...

Page 44

 # 
Second screen (2/2)













VALVE RETURN (Valve close timer (former name: TIMER 20) 
Default: 300 
Setting range: 1 – 9999 [msec] 
]Function^ 
CThis timer starts functioning when the judgment delay timer comes up, and UEC switch off the valve 
(valve on) when this timer comes up.   
Guideline of setting 
C300 [msec] for the valve integrated type tools like MC wrenches 
C500 [msec] or longer for the valve external type tools like ULMC series.    If the external valve is 
away from...

Page 45

 ## 


LINE CONTROL (Line control timer (former name: TIMER 50) 
Default: 100 
Setting range: 1 – 9999 [sec] 
]Function^ 
CUse this timer when either 2 or 3 is set to LINE CNT. SELECT (former name: MODE 14).    This 
timer is to make line control by time.     

 
YEAR  
Default: 0 
Setting range: 0 – 255 [Year] 
]Function^ 
CThis is to set the year of calendar timer of UEC.     
CEnter 0, and the year of calendar timer is set to [Year 2000].    Enter 6, and the year of calendar time 
is set to...

Page 46

 #&  
#Input and output setting 
 
Signal allocations of input and output terminal board is free format.  You can change signal 
allocations as required by setting.   

INPUT 1 (Input terminal select 1)
Set the signal allocations of input terminals by INPUT 1 to INPUT 5.











Default and name of terminal


Setup item
Entry  Name of Signal  Function 
1 LS 1 When 0 is set to LINE CNT. SELECT, provide judgment signal.     
When either 1 or 2 is set, provide start fastening process...

Page 47

 #

OUTPUT 1 (Output terminal select 1)
Set up the signal allocations of output terminals by OUTPUT 1 – OUTPUT 5.












Default and name of terminal
Setup item  Default (function)  Name of terminal 
OUTPUT 1DdddddE  1  (COUNT OK)  COUNT OK 
OUTPUT 2DdddddE  2  (COUNT NOK)  COUNT NOK 
OUTPUT 3DdddddE  3  (TORQUE OK)  TORQUE OK 
OUTPUT 4DdddddE  4  (TORQUE NOK)  TORQUE NOK 
OUTPUT 5DdddddE  5  (SV)  SV 

Setup item
Entry  Name of signal  Function 
1 COUNT OK Count OK signal...

Page 48

 #  
&Data output setting 
Determine the contents of the output data and memory data sent through RS232C port.    
 
 
First screen (1/2) 
 
 
 
 
 
 
 
 




UEC NO. (Former name: MODE 98) 
Default: 1 
Setting: 1 – 25 Give every UEC its own number when plural UECs are in use connected   
by RS232C.   


OUTPUT MOVEMENT (former name: MODE 58) 
Default: 0 
Setting : 0Output all data through RS232C 
Setting: 1 Output only the following errors through RS232C 
CTorque/Pulse number/High & Low...

Page 49

 # 
COMM. SPEED (
Communication speed select (baud rate) (former name: MODE 60) 
Default: 1 
Setting: 0  4800 bps 
Setting: 1  9600 bps 
Setting: 2  19200 bps 
]Function^ 
This is to determine the baud rate of the output data sent through data output RS232C port.     
Note: This is not the communication speed between PC and UEC.   



BIT HEAD (Bit length select (former name: MODE 61) 
Default: 1 
Setting: 0  7 bit 
Setting: 1  8 bit 
]Function^ 
This is to determine the bit length of output...

Page 50

 #% 
Second screen (2/2)












PULSE NUMB. (Pulse number output select (former name: MODE 67) 
Default: 1 
Setting: 0   Not output  
Setting: 1   Output (4 byte) 
]Function^ 
This is to determine whether include or not the pulse number in the output data sent through data 
output RS232C port.   


FASTENED TIME (Fastening time output select(former name : MODE 68) 
Default: 1 
Setting: 0  Not output 
Setting: 1    Output (4 byte) 
]Function^ 
This is to determine whether...