Page 81
“User name” and “password”. Since the controller only contains one password (one user) the “User name” can be left blank. Once the password is entered it is returned to the controller were it will be checked and if it is correct the parameters are saved. If it is incorrect the controller will request it from the bro wser again. After a password has been entered most browsers will cache it and return on subsequent request without prompting the user. So as long as the browser is not closed it...
Page 82
5. Controller Name: Optional variable that is passed through the Op en protocol connection. To set up a serial port for Open protocol set the function on the desired COM port to “Open Protocol” and cycle the power on the controller. The Controller supports the following MIDs. See the latest Open protocol specification for details on each MID. MID Description Note 0001 Communication start 0003 Communication stop 0010 Parameter set numbers upload request 0018 Select Parameter set...
Page 83
19.1.5 AIMCO Database The controller has the ability to send rundown data to an AIMCO data collection server. Once the controller is on the local network there are two parameters that must be set to store data correc tly on the server. 1. Server IP Address: This is the IP address of the AIMCO data collection server. If the server is on another subnet you will also have to verify the gateway in the Ethernet settings. 2. Server Port Number: This is the TCP port the server is listening on...
Page 84
Controller Inputs Bits 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Address 1024 Handshake Abort Enable Process number Bit name Function 0-7 Process Number Process number input. The enable must be off to change the Process Number. On a change to the Process Number the batch is also reset. 8 Enable On the rising edge of Enable the tool will be enabled. 9 Abort If Abort is on the tool will be disabled. 10 Not used 11 Not used 12 Not used 13 Not used 14 Not used 15...
Page 85
Byte Bit Name Function 0 0 Tool Enable The enabled state of the tool. 1 Tool Ready On if the tool is ready to run. Will be off if tool is disabled or there is a fault on the controller. 2-7 Not used 1 0 Status OK Rundown status on for an accept. This bit is timed and will be on for ½ second. 1 Status NOK Rundown status on for a reject. This bit is timed and will be on for ½ second. 2 Msg Received On to indicate a message has been received from the MKS module and the inputs have changed....
Page 86
Byte Bit Name Function 0 0-7 PSET Set the active parameter set of 1-32. If 0 the active parameter set is left unchanged. 1 0 Tool Enable If PLEC Enable is 0 this input is ignored. If PLC Enable is 1 this bit can be used to enable or disable the tool. 1-3 Not used 4 Pause Setting Pause to 1 cause the light stack to strobe. Setting it to 0 put the light stack back into its normal operation. 5 White Flash Setting White Flash to 1 cause the light stack to flash the white...
Page 87
19.3 Data Output Settings The use of Ethernet or ot her field busses requires that the data output settings of the UEC -4800 are configured correctly. This can be done from either the UEC -4800 front panel or the setup software. UEC Data Output Settings Field Value Meaning UEC No 01 UEC Identifier Number Out Movement 0 Output all data through RS232C Output Form 0 #-CR Comm Speed 1 9600 bps Bit 1 8 bit Stop 0 1 bit Parity 0 No parity Torque Val Trans 1 Output Pulse Numb 1 Output...
Page 88
19.3.2 Data Output Configuration from PC 1) Turn on the UEC -4800 and wait for self- diagnosis check to finish. 2) Connect the front PC port on the UEC -4800 to a PC with the UEC -4800 setup software using a straight serial cable . 3) Start the setup software on the pc. 4) Go to ‘Main Menu’ (F12) and then ‘File Selection’ (F1) and select your configuration file or create a new one. If a settings file is not present or settings need to be downloaded then proceed to the next...
Page 89
6) Check that the settings match the settings below. If not then change the appropriate settings. 7) Click ‘Send’ to send new parameters to the UEC -4800. Data Output Settings Menu 19.3.3 Downloading/Importing UEC -4800 Settings The settings on the UEC -4800 can be downloaded from the device using the PC setup software. If a tool hasn’t been selected under Main Menu Tool Selection th en some of these menu items may be disabled. 1) Connect the front PC port on the UEC -4800 to a PC...
Page 90
Set Menu – Where to download/import UEC -4800 Settings 20. Light Tower Color Definitions UEC - LIGHT ASSIGNMENT FOR LIGHT TOWER AND KEY BYPASS Light Color Judgment Assignment Green Accept UEC Red High Torque UEC Red Flashing Fault other than High Torque, Pulse Count, and Angle Errors UEC Yellow High Pulse/Angle UEC Yellow Flashing Low Pulse/Angle UEC Blue Bypass Key Bypass White Tool Enabled UEC White Flashing Open External Lights Strobe Open External