TIME CONT. ST.  (Compulsory judgment)  (Former name: MODE 6) 
Default: 0 
Setting: 0 Do not make compulsory judgment   
Setting: 1 Makes compulsory judgment and stops the tool when cycle error detection timer comes 
up.    
]Function^ 
CUse when you want to control fastening time without cycle error detection.   
CUEC compulsory switches on solenoid valve to stop the tool and provides judgment if the tool fails to 
reach torque cut value beyond start torque value after cycle error detection timer...

Page 32

  
Second screen (2/4) 
 
 
 
 
 
 
 
 
  
 
 
 
 
 
Control method (former name: MODE 9)   
Default: 3 
Setting: 1 Torque monitor   
Provides the judgment to the measured torque, but does not control the torque.       
Use to monitor the torque of the mechanical clutch type nutrunners etc.     
Setting: 2 Torque control   
Controls and provides the judgment to the measured torque 
Use mainly for the pneumatic nutrunners   
Setting: 3 Torque control for MC wrenches and EC wrenches 
Use mainly for the...

Page 33

 

LINE CNT. SELECT (Line control method select) (former name: MODE 14) 
Default: 0 
Setting: 0   
UEC is always ready to count down the fasteners, and provides the judgment at the time of limit switch 
is switched on.    UEC provides COUNT OK judgment if the preset number of fasteners is fastened up.   
When the LS (limit switch) 1 terminal is switched on, UEC is reset and ready for next operation.    UEC 
provides COUNT NOK if any fasteners are left unfastened when LS1 is switched on.    Tighten the...

Page 34

 
Setting: 2 
Switch on the limit switch, and the operation starts and UEC provides the judgment when the timer 
comes up.    Operation starts by switching on LS1 terminal, and the line control timer starts functioning.   
UEC provides COUNT NOK if the line control timer comes up before the preset number of fasteners is 
fastened up.   













Setting: 3
Limit switch is not used, but the line control timer starts functioning by the first fastening operation.     
Line control timer...

Page 35

 #

Setting 4 
By any of WORK 1 – 5 signal input, UEC gets ready to start fastening of the selected work number. 
Set 1 to WORK SIG. SEL.     
When the preset fasteners are fastened up, COUNT OK signal terminal is switched on corresponding 
to the selected work number.  [WORK 2 COUNT OK] output terminal is switched on when UEC 
provides COUNT OK of work No. 2.     
Set up the COUNT OK signal output duration time per work number in COUNT OK of TIMER 
SETTING.   
UEC provides COUNT OK signal output for 1...

Page 36

 & ALARM BUZZER (Fastening confirmation buzzer output) (former name: MODE 15)
 
Default: 0 
Setting: 0 Buzzer does not sound.   
Setting: 1 Buzzer sounds for every OK fastener. 
]Function^ 
CBuzzer gives 1 pulse sound for every OK fastener, and 2 pulses sound for fastener COUNT UP.   
 
 
ST. TORQUE ERROR (Start torque error detection) (former name: MODE 16)   
Default: 0   
Setting: 0 Not detect the start torque error 
Setting: 1 Detect the start torque error 
]Function^ 
CUEC detects the start...

Page 37

  PULSE LOW (Pulse number low limit value [pulse]) (former name: MODE 34) 
Default: 2 
Setting range: 0 – 9998 (pulse number low limit value, maximum 9998, < pulse number upper limit 
value, maximum 9999) 
]Function^ 
CPulse number that UEC provides pulse number LOW NOK judgment.    UEC provides pulse number 
LOW NOK if the total pulse number generated from the start torque until the cut torque is less than 
the pulse number low limit value.     
]When UEC detects the error^ 
CTouch panel display...

Page 38

  TORQUE CUT CONP. (Torque measurement during compensation pulsing post CUT level) 
Default: 0 
Setting: 0 UEC measures, controls and provides final judgment with the highest peak torque display 
of compensation pulsing under the pulse number counting.     
Setting: 1 UEC gives judgment due to torque measurement of pulsing until torque cut level, but does 
not measure torque of pulsing post torque cut level.   
 
 
ADDITION. PULSE (Compensation pulse numbers post CUT level) (former name: MODE 27)...

Page 39

  
Fourth screen (4/4)












ANG LOW LMT (Angle low limit value [degree]) 
Default: 0 
Setting range: 0 - 999 
]Function^ 
CThis is angle low limit judgment value   
CUEC provides angle LOW NOK if measured angle is smaller than preset angle low limit at the time 
of judgment.   
CIf 0 is set, UEC does not provide the angle low judgment.   
]When UEC detects the error^ 
Touch panel display message: [Angle low] 
Buzzer sounds. 
Terminal: TORQUE NOK terminal is kept switched on until...

Page 40

 % 

ANG SNUG TRQ (Snug torque) 
Default: 15   
Setting range : 0.0 – 999.8  
Setting condition: Start torque value < Snug torque value < CUT torque value   
]Function^ 
CThis is the torque from when UEC started measuring the angle.


ANG CUT (Angle CUT value)  
Default: 999 
Setting range : 0 - 999 
Setting condition: Angle lower limit value < angle CUT value < angle low limit value     
]Function^ 
This is the fastening stop angle judgment value when the angle control is effective.   