Page 21
Input and Output check (wiring diagnosis of the terminals and the tool) By monitoring the input condition to the terminal block and making the compulsory signal output to either the terminal block or the tool, UEC checks the incoming wirings of the terminals of UEC, the tool and the sensor cable connected. If you enter the IN-OUT CHECK screen, UEC starts from the check of the input terminals. Input terminals now been switched on are colored in blue. ...
Page 22
Zero point adjustment UEC displays the values of the torque sensor’s zero point and the cal number confirmed by the zero check and cal check. Displayed values are of the absolute values. [ZERO] shows the zero point value, and [PROOFREADING VALUE] shows the calculated value of CAL x Proofreading Ratio x Tool Ratio. If the zero point deviates around [0], touch to have UEC correct the zero point deviation. A message ZERO POINT ADJUSTING… appears in...
Page 23
WORK No. change UEC makes the work number change by short-circuiting the input signal terminals and the common terminal. In accordance to the setting value of WORK SIG. SEL. of the MODE SETTING screen, the input signals to the terminals become different. Input signal to the terminal If 0 is set to WORK SIG. SEL. If 1 is set to WORK SIG. SEL. Work number to be selected No signal input WORK 1 WORK 1 WORK A WORK 2 WORK 2 WORK B WORK 3 WORK 3 WORK A WORK B WORK 4...
Page 24
%Torque polarity change Unless torque polarity of UEC is changed over, UEC is unable to either measure the torque of the left- hand threaded fasteners or control the geared transducerized tools because the torque signal from the tool is input in the minus direction. You need to change over the UEC’s torque polarity for left-hand threaded fasteners. Change over is made by DIP switch in the board inside of UEC. CChange the setting of DIP switch [SW3]...
Page 25
# Setting Setting screen is sorted out as mentioned below. ]BASIC SETTING^ Basic setting for the fastening like CUT (target value), LOW (lower limit), HIGH (upper limit) etc ]MODE SETTING^ Setting for the line control method, use selection of various functions etc. ]TIMER SETTING^ Setting for the various timers ]IN/OUT SETTING^ Setting for the allocations of input and output signals to the terminal ]DATA OUT SETTING^ Setting for the data output from the RS-232C serial port in...
Page 26
& Basic setting The BASIC SETTING screen consists of two pages. First screen (1/2) TORQUE LOW (Torque low limit value) Default: 80.0 [Nm] Setting range: 0.0 –999.7 Setting condition: Torque low limit value < Torque CUT value ]Function^ Value for the measured torque low limit judgment TORQUE HIGH (Torque high limit value) Default: 60.0 [Nm] Setting range: 0.4 –999.9 Setting condition: Torque CUT value < Torque high limit value...
Page 27
TORQUE SENSOR 1 (Torque sensor resistance value []) Default: 700 ]Function^ Resistance value consisting of torque sensor circuit Choose from 480, 700 or 350, which agrees to the specifications of torque sensor connected. Set [700] for EC wrenches Do not enter any value for MC wrenches. Setting value is not displayed on the screen if the sensor select switch is set to MS. TORQUE SENSOR 2 (Torque sensor rated strain value) Default: 750 Setting range: 100 - 4400...
Page 28
Second screen (2/2) PROOFREADING RATIO Default: 1.00 Setting range: 0.01 _ 9.99 ]Function^ This is the proofreading ratio which makes the break-away torque agree to the UEC displayed torque. TOOL RATIO Default: 1.00 Setting range: 0.01 – 9.99 ]Function^ This is the reduction ratio of the geared pulse tool. PROOFREADING VALUE Default: 1000 Setting range: 0.01 – 9.99 ]Function^ Proofreading ratio x Tool ratio x CAL value...
Page 29
MODE Setting MODE SETTING screen consists of four pages. First screen (1/4) INITIAL ERROR (Initial error detection) (former name: MODE 1) Default: 0 Setting 0: Not detect the initial error Setting 1: Detect the initial error ]Function^ Use to detect the double-fitting or cross thread. UEC detects the initial error if the consumed time from start torque level to torque cut value is less than time of the initial error detection timer....
Page 30
% FASTENING ERROR (After of post error detections LO.E/CYL.E/F.E) (Former name: MODE 3) Default : 1 Setting : 0 UEC gets non-operative status unless is touched or reset terminal is switched on. Valve remains switched on. Setting : 1 Next operation performs start-reset without touching or switching on reset terminal, and UEC gets operative status. If 0 is set to EXTERNAL START, the torque input (greater than start torque value) of next operation performs start-reset and...