&Installation 
Install and fix controller firmly by paying attentions to the followings.   


& Place for Installation 

1)  Within a building where no water or direct rays of the sun enters because UEC is not the 
waterproof structure. 
2)  Place where UEC does not suffer from corrosives, flammable gas, grinding fluid, oil mist, metal 
powders, and etc. 
3)  Well-ventilated place with less moisture, dust or waste. 
4)  Less vibration place 
5)  Place where you can disconnect power cord...

Page 12

 
Specifications

Item Descriptions 
Power Source  AC 100 – 240V +/- 10% 
Frequency  50 / 60 Hz 
Anti-noise  1000V 1S (by noise simulator) 
Insulation 
resistance DC500V & greater than 10M 
Consumption about 30VA 
Weight  Touch Panel type: 3.6 kgs    LCD type: 3.4 kgs 
Dimensions  265 (D) x 222 (W) x 120 (H) 
Main Features Torque Control / Monitor 
Fastener Number Count 
From Front Panel Setup 
By PC (exclusive URYU setup software, common for UEC-4800/4800TP, necessary) 
Torque Resolution +/-...

Page 13

 
#Parts names and functions
#$	
(



















(	22
/
Switch for power supply.    Turn off when you do not use UEC.   

 ==
Sounds to announce every fastening, error, OK or NOK.    Touch the screen and the buzzer sound 
stops when an error is detected.

PC connector (D-sub 9-pin male)
Connector to connect to PC 
Use the straight cable.   

	Touch panel
Display and input the fastening data such as the torque, fastening time, pulse number...

Page 14

   
#Rear Panel











GPower cord box
Connect the power cord.    Make sure to ground the grounding wire of the power receptacle.     

HFuse holder
Protections fuse of UEC (3.15A)

I
PC connector (D-sub 9-pin female)
RS232C serial port for the data output to be used for 
serial printer, PLC, PC, and barcode reader







J
Sensor cable connector CN-1
Connect sensor cable from a tool

K
Sensor select switch
Select switch of either MS (URYU original Magnetostrictive...

Page 15

 # 

WNetwork connector
Connector for Ethernet to connect to the database


XInput and Output terminals (free format)










Terminal 
No.

Signal allocations
Terminal 
No.

Signal allocations
A1 COM: Common terminal for the input 
terminals (-)
 B1
COM: Common terminal for output 
terminals
 
A2 LS 1: Input the line control signal B2COUNT ON: Output COUNT OK signal 
until timer comes up
 
A3 START: External start B3COUNT NOK: Output COUNT NOK signal 
until NOK is cleared
 
A4...

Page 16

 & 
5Operation 

&Preparation 
1)    Connect the power cable to the power receptacle.     
2)    Connect Sensor Cable to CN-1 Connector of UEC, and connect sensor cable to a tool.     
3)    Switch on UEC, and it makes the self-diagnosis check for 10 seconds.     
4)    The TORQUE MONITOR screen comes up after the self-diagnosis check is completed.












&Key operation
1)  Switch on UEC, and it makes the self-diagnosis check.    After it is over, the TORQUE MONITOR 
screen...

Page 17

 
  
&Setting
There are two ways available, either by PC or by touch panel screen of UEC, to change the setting 
values.
 
(1)    By PC (Please refer to the instruction manual of UEC-4800 setup software for details.)     
1)  Connect the communication cable, straight cable, to [PC] connector in the front panel of UEC, and 
connect to PC through RS232C or Ethernet of NETWORK connector in the rear panel.     
2)  Change the setting values through the setup software.     
3)  Upload the setting...

Page 18

  













































 5)  Touch 
  to move to
 the 
next page and touch
 
 to 
move to the previous page. 
6) Touch a cell of WORK 1 to select the work number that you want to 
set up the parameters and touch 
 to determine.   
7)    Touch the setup item that you 
want to change the parameters. 
8)    Input the numeric number and touch
 
 to determine.    If the input value is 
settable one, it is written.    If the input value...

Page 19

 
6Check 

Touch 
 on the MENU screen to move to the CHECK screen, and you can have UEC 
the self-diagnosis check and the input and output terminal signal check.
  Self-diagnosis check 
performs the check of the controller inside, touch panel display, and input.     
Input and output check performs the check of the input and output wires of the terminal block.   











Self-diagnosis check
If you select SELF-DIAG.CHECK, UEC starts the self-diagnosis check of the controller...

Page 20

 % 5)  ZERO point change value check   
It checks the deviation from the torque sensor output voltage 0V under no load condition.   
UEC provides the zero error if the zero point deviation, either DPM display zero point value or PC 
display zero point adjusting screen value, is out of the range of from –6 to +6% of the rated value.     
6) CAL check  
It checks if the torque sensor wiring and sensor specifications are appropriate to the sensor 
setting value.   
UEC provides the cal error if the torque...