Aimco Brakes Monitor UEC4800TP Instruction Manual
Have a look at the manual Aimco Brakes Monitor UEC4800TP Instruction Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 85 Aimco Brakes manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
&Installation Install and fix controller firmly by paying attentions to the followings. & Place for Installation 1) Within a building where no water or direct rays of the sun enters because UEC is not the waterproof structure. 2) Place where UEC does not suffer from corrosives, flammable gas, grinding fluid, oil mist, metal powders, and etc. 3) Well-ventilated place with less moisture, dust or waste. 4) Less vibration place 5) Place where you can disconnect power cord from power socket immediately when anything unusual occurs to UEC. 6) Set in a dust-free box in case of use under environment of contamination degree 3. & Environmental conditions Item Conditions Place Indoors only Operation temperature 0 – 50 degree (no freeze) Humidity 90% RH or less (no dew) Preservation Temperature 0 – 50 degree (no dew) Preservation Humidity 90% RH or less (no dew) Vibration 5.6 m/s2 or less (10 – 60 Hz) Altitude Maximum 1,000 m above sea level Over voltage Category Category III *1 Contamination Degree Degree 2 *1: Above categorization is of the over voltage category (I, II or III), and contamination level (1, 2, 3) as per IEC664. UEC-4800 has been categorized as above mentioned over voltage category III and the contamination degree 2. Note: IEC International Electric Standard Committee
Specifications Item Descriptions Power Source AC 100 – 240V +/- 10% Frequency 50 / 60 Hz Anti-noise 1000V 1S (by noise simulator) Insulation resistance DC500V & greater than 10M Consumption about 30VA Weight Touch Panel type: 3.6 kgs LCD type: 3.4 kgs Dimensions 265 (D) x 222 (W) x 120 (H) Main Features Torque Control / Monitor Fastener Number Count From Front Panel Setup By PC (exclusive URYU setup software, common for UEC-4800/4800TP, necessary) Torque Resolution +/- 2048 (12 Bit by A/D) Touch Panel : Display 320 x 240 dot (25 letters x 15 lines – in case of Japanese two-byte character) LCD (20 letters x 4 liners) Work number, Bolt Count number, Tightening Time, and Pulse Blow Number displayed 1-digit Digital Display (DPM) Work number displayed 4-digit Digital Display (DPM) Torque Reading displayed TOTAL Lamp (for Count Judgment): OK (Green) / NOK (Red) Lamp (display on screen) Torque Lamp (for Torque Judgment): LOW (yellow) / OK (green) / High (Red) Input Operation Voltage / Current: DC24V / about 10mA 5 terminals available (free format) Note: Contact input necessaryTerminal Block Output Contact Capacity: DC30V, 1A 5 terminals available (free format), VALVE Oscillograph output Plug Size: JIS C6560 single small head plug 3.5 x 15 UEC outputs filter-processed torque waveform from analog jack Cable: UK-PLUG (Part Number: 909-483-0) Key Display on the touch panel screen: DENTERE, DRESETE, & 10 key Display on the LCD type front panel FF Front Panel (touch panel type) Part Name: Touch Panel Assembly Part Number 910-073-0 Front Panel (LCD type) Part Name: UEC-LCD Panel Assembly Part Number: 910-072-0 Part Name: PC Cable Part Number: 910-219-0 Straight PC Cable for RS232C D-sub 9-pin female and D-sub 9-pin female (3 meter long) Option Torque Sensor Cable Part Name: Sensor Cable Assembly 3F5 Part Number: 910-263-0 Part Name: Sensor Cable Assembly 3F10 Part Number: 910-264-0
#Parts names and functions #$ ( ( 22 / Switch for power supply. Turn off when you do not use UEC. == Sounds to announce every fastening, error, OK or NOK. Touch the screen and the buzzer sound stops when an error is detected. PC connector (D-sub 9-pin male) Connector to connect to PC Use the straight cable. Touch panel Display and input the fastening data such as the torque, fastening time, pulse number and judgments, the fastener unfastened number, date and hour, torque wave form, errors, warnings and or the setting values. Touch the screen when the buzzer sounds by detecting the error, and the buzzer stops without clearing the error. G H I J
#Rear Panel GPower cord box Connect the power cord. Make sure to ground the grounding wire of the power receptacle. HFuse holder Protections fuse of UEC (3.15A) I PC connector (D-sub 9-pin female) RS232C serial port for the data output to be used for serial printer, PLC, PC, and barcode reader J Sensor cable connector CN-1 Connect sensor cable from a tool K Sensor select switch Select switch of either MS (URYU original Magnetostrictive type sensor) or SG (strain gauge type sensor). Set this switch to [MS] when you use MC wrenches. L Analog output terminal Terminal for the torque waveform output. Please refer to 16. Torque Waveform Measurement and 17. ANALOG output terminal for details. MSpace for Optional Board Space for optional board Pin Purposes Pin # Purposes 1 FG (Frame Ground) 2 TXD (Transmit Data) 3 RXD (Receive Data) 4 DSR (Data Set Ready) 5 SG (Signal Ground) 6 DTR (Data Terminal Ready) 7 CTS (Clear to Send) 8 RTS (Request to Send) 9 Not Used N O P Q R S T 10 U V NR VU
# WNetwork connector Connector for Ethernet to connect to the database XInput and Output terminals (free format) Terminal No. Signal allocations Terminal No. Signal allocations A1 COM: Common terminal for the input terminals (-) B1 COM: Common terminal for output terminals A2 LS 1: Input the line control signal B2COUNT ON: Output COUNT OK signal until timer comes up A3 START: External start B3COUNT NOK: Output COUNT NOK signal until NOK is cleared A4 RESET: Use to clear NOK B4TORQUE OK: Output TORQUE OK signal until timer comes up A5 WORK A: Input for the work No. change B5TORQUE NOK: Output TORQUE NOK signal until NOK is cleared A6 WORK B: Input for the work No. change B6 SV: Output for change of slow speed or full speed. Output SV signal when the measured torque reaches the start torque. A7 B7VALVE: Valve Output (0V) A8 B8VALVE COM: +24 A9 B9 A10 Not used B10 Not used Allocation of terminal board is free format. You can change the signal allocations of A2 – A6 and B2 – B6 by IN/OUT SETTING. Inputs A7 – A10 and outputs B9 & B10 are not used. Note: Contact input is necessary for the input to the input terminals A1 and A2 – A6. Output terminals of B1 and B2 – B6 are the no-voltage output. Wiring should be made at DC24V or less. Use Y-shape crimp contact or round-shape contact for the wiring. YGrounding terminal Terminal for grounding. Make sure to use this terminal if the power cord does not have a ground wire. Terminal No. : A1 Terminal No. : B1 Terminal No. : A10 Terminal No. : B10 Terminal No. : A6 Terminal No. : B8
& 5Operation &Preparation 1) Connect the power cable to the power receptacle. 2) Connect Sensor Cable to CN-1 Connector of UEC, and connect sensor cable to a tool. 3) Switch on UEC, and it makes the self-diagnosis check for 10 seconds. 4) The TORQUE MONITOR screen comes up after the self-diagnosis check is completed. &Key operation 1) Switch on UEC, and it makes the self-diagnosis check. After it is over, the TORQUE MONITOR screen comes up. 2) Touch on the TORQUE MONITOR screen to move to the WAVE FORM MONITOR screen. Touch on the WAVE FORM MONITOR screen to move back to the TORQUE MONITOR screen. 3) Touch to cancel the fastening error display or to make the ZERO/CAL check on the TORQUE MONITOR screen. 4) Touch in the TORQUE MONITOR screen to move to the MENU screen. 5) Touch the screen name in the MENU screen to move to the touched screen. 6) Touch in the screen other than to move back to the TORQUE MONITOR screen 7) Touch the screen anywhere excepting to stop the buzzer when UEC detects the error. Touch to cancel the error display. 3 Touch except for the error status to reset the UEC-4800TP including clearing the bolt counting.
&Setting There are two ways available, either by PC or by touch panel screen of UEC, to change the setting values. (1) By PC (Please refer to the instruction manual of UEC-4800 setup software for details.) 1) Connect the communication cable, straight cable, to [PC] connector in the front panel of UEC, and connect to PC through RS232C or Ethernet of NETWORK connector in the rear panel. 2) Change the setting values through the setup software. 3) Upload the setting values to UEC. (2) From the touch panel screen 1) Touch in either the TORQUE MONITOR screen or the WAVE FORM MONITOR screen to move to the THE MODE CHOICE screen. 2) Touch in the THE MODE CHOICE screen to move to the PARAMETER SETUP screen. 3) Select in the PARAMETER SETUP screen the setting that you want to change the setting values. 4) Numeric keypad comes up in the MODE SETTING screen. Touch for over 3 seconds to enter the writing mode. Message [SETUP VALUE EXCHANGE] appears at the top of the screen while in the writing mode, and the contents of the setting value appears at the bottom. Setting range and condition appears. PULSE
5) Touch to move to the next page and touch to move to the previous page. 6) Touch a cell of WORK 1 to select the work number that you want to set up the parameters and touch to determine. 7) Touch the setup item that you want to change the parameters. 8) Input the numeric number and touch to determine. If the input value is settable one, it is written. If the input value is out of the setting range or the interlocking value error such as the torque lower limit value < torque cut value happens, you need to input the settable value again. 9) Touch to escape from the writing mode to finish the parameter change, and move back to the TORQUE MONITOR screen. Parameters were changed, and you are ready to start the fastening. Page/Total Page
6Check Touch on the MENU screen to move to the CHECK screen, and you can have UEC the self-diagnosis check and the input and output terminal signal check. Self-diagnosis check performs the check of the controller inside, touch panel display, and input. Input and output check performs the check of the input and output wires of the terminal block. Self-diagnosis check If you select SELF-DIAG.CHECK, UEC starts the self-diagnosis check of the controller inside. A message SELF-DIAG. CHECKING appears on the screen. If the error is detected, UEC displays the error code like the cal check error. If there is no error detected, a message SELF-DIAG. CHECK OK appears. [Contents of diagnosis] 1) ROM IC operation check It checks if the memory IC (ROM), which memorizes the control program of UEC, operates properly or not 2) RAM IC operation check It checks if the memory IC (RAM), which memorizes the setting values, measured data etc. of UEC, operates properly or not. 3) A/D IC operation check It checks if the analog-digital converter IC (A/D), which measures the torque data in analog value by CPU, operates properly or not. 4) Setting value storage data check (SUM check) It checks if there is no error in the setup data memorized in RAM IC
% 5) ZERO point change value check It checks the deviation from the torque sensor output voltage 0V under no load condition. UEC provides the zero error if the zero point deviation, either DPM display zero point value or PC display zero point adjusting screen value, is out of the range of from –6 to +6% of the rated value. 6) CAL check It checks if the torque sensor wiring and sensor specifications are appropriate to the sensor setting value. UEC provides the cal error if the torque sensor output signal is out of the range from 94 to 106% of the rated value in condition that UEC applies simulative electric pressure to the torque sensor so as to put the torque sensor in the virtual condition under rated load strain. 7) Key/LCD check Key/LCD check starts when the self-diagnosis is over. [+] appears on screen where you touch. Screen color changes by your touch. Press to finish the key/LCD check, and move to the CHECK screen. Z