& WAVE DATA CNTNT SLCT (Wave data content output select) Default: 1 Setting: 0 Not output Setting: 1 Output Setting: 2 Output when NOK ]Function^ This is to determine whether output or not waveform data to UEC-4800 setup software. This will not sent to the RS232C port on the back panel. ANG DATA TRANSM SLCT (Fastening angle output select (former name: MODE 65) Default: 1 Setting: 0 Not output (“0000” to be transmitted) Setting: 1 Output (4 bytes) ]Function^ This is to determine whether include or not the angle in output data sent through data output RS232C port. WAVE DATA FORM (Wave form data output select) Default: 0 Setting: 0 Send by Binary format (2 byte per data) Setting: 1 Send by ASCII format (4 byte per data) ]Function^ This is to determine the file format to send waveform data to the UEC-4800 setup software. Set 0 (Binary) at present. ID DATA SLCT (ID data output select) Default: 0 Setting: 0 Not output Setting: 1 Output ]Function^ This is to determine whether include or not ID number in output data sent through data output RS232C port. ID DATA NUMB. (ID data digit number) Default: 0 Setting range: 1 - 48 ]Function^ This is to determine the digit number of VIN NO. Not used digit is filled with [0].
& LAN setting This is to set up for Ethernet connection. Set up the value in LAN SETTING screen, and a message [LAN SETTING] appears. It takes approx. 20 seconds after you change setting values and a message [LAN SETTING] goes off from a screen. Please do not touch . LAN setting screen consists of three pages. First screen (1/3) IP ADDRESS 1 - 4 Default: 120.0.100.1 Setting range: 0 - 255 CThis is to determine the IP address of UEC. SUBNET MASK Default: 8 Setting range: 1 - 31 Setting: 1 (255.255.255.254) 8 (255.255.255. 0) 16 (255.255. 0. 0) 24 (255. 0. 0. 0) 31 (128. 0. 0. 0) CThis is to set up Subnet mask. DEFAULT GATEWAY 1 - 4 Default: 0 Setting range: 0 - 255 CSet up when connecting to PC via router. Set up the parameters when you hook up your PC to controller via router.
& Second screen (2/3) TCP PORT Default: 2101 Setting range: 0 - 9999 CThis is to set up the TCP port of UEC. CONNECT MODE (Connection mode) Default: 1 Setting: 0 Set UEC as host Setting: 1 Set UEC as client CSet [1] (UEC as client), when connecting to the UEC-4800 setup software. HOST IP address 1 - 4 Default: 120.0.100.0 Setting range: 0 - 255 This is to set up the IP address of PC which communicates with UEC through Ethernet. REMOTE TCP PORT Default: 2101 This is to set up TCP port of PC which communicates to UEC through Ethernet. Set up with same value of TCP port of UEC.
& Third screen (3/3) LAN RETRY NUM. (LAN retry number) Default: 3 Setting range: 0 - 10 CThis is to determine the retry number to be made. Comm.-less time (LAN nonresponding limit time) Default: 10 Setting range: 0 - 10 CThis is to determine waiting time in case of nonresponding. MAC ADDRESS Default: Assign unique address Setting range: 0 - 9999 CMac address of UEC. CImpossible to change the setting value.
Program Number Change This is to set the program number choice. Maximum 8 kinds (fastening torque, judgment values of torque and angle etc.) of program can be set up per work. It is possible to set up maximum 20 fasteners under same work number. 8 kinds of work number (from program 1 to 8) can be set up for first fastener up to 20th fastener. This function is available with the V1.15 UEC-4800TP or later. PRG. CHANGE SLCT (Program change select) Default: 0 Setting: 0 Not use Setting: 1 Use, and program number is selected by signal input from terminal of UEC. Setting: 2 Select program number by the 32-byte data received on the serial port on the rear panel. Set 1 to ID DATA SLCT, and set 32 to ID DATA NUMB in the DATA OUT SETTING screen. Setting: 3 Receive work number signal from 48-byte data received on the serial port on the rear panel. Set 1 to ID DATA SLCT, and set 48 to ID DATA NUMB in the DATA OUT SETTING screen. ]Function^ CThis is to determine whether use or not the program number choice, and how to change program number. CWhen setting value is changed from 0 to any of 1 – 3 or vise versa, UEC clears memory data. It is because UEC memorizes program number when program number choice is used.
&& PRG. CHANGE SWIT (Program change switch) Default: 0 Setting: 0 Switch to next work number only when UEC provides fastening OK. Setting: 1 Switch to next work number whichever UEC provides fastening OK/NOK. Setting: 2 Switch to next work number when UEC provides OK or torque HIGH NOK. ]Function^ CThis is to determine the condition to have UEC switched to next work number when program number choice is used. First – 20th Fastener Default: 0 Setting range: 0 - 8 Setting: 0 Fastening is ended. 1 – 8: Fastening is performed per setting of selected work number. ]Function^ CThis is to determine which fastener is fastened by which setting of work number. ]Setting example^ Set either 1 or 2 to PRG. CHANGE SLCT, and set 1 to First, Second and Third fastener, and 2 to Fourth fastener. First, second and third fastener is fastened up to CUT values of WORK 1 setting, and judged in accordance to WORK 1 setting. Fourth fastener is fastened in accordance to WORK 2 setting. Set 0 to fifth fastener, if the fastening is ended with fourth fastener. If either 1 or 2 is set to PROG. CHANGE SWIT, it is possible to fasten up to 20 fasteners. It is possible to set up work number to each fastener from first up to 20th. Work number select is settable with maximum 8 kinds from program 1 to 8. When 3 is set to PROG. CHANGE SLCT., work number combination and fastening number and fastening are decided and received from the serial port on the rear plane. Select Program No. you want to set up parameters. Selectable from program 1 up to 8.
& 11Memory Data This is to set up the setting of memory data related items and display memory data like average, , original data etc. (1) Touch in the measuring screen to enter MENU screen. (2) Touch to move to MEMORY DATA screen. Menu of MEMORY DATA is displayed. Select the screen you want to set up or change the setting values. Memory data screen consists of following five pages. ]SETUP OF MEMORY^ Set up for the contents of memory ]STATISTICS DATA^ Display N (memory data number) per work number, calculated average and CP value etc. ]FORMER DATA^ Display former memorized data per work number ]MEMORY DATA CLEAR^ Clear data memorized in UEC ]UNUSUAL HISTORY^ Display the error history stored in the UEC-4800TP Memory related setting AVR (Average value) CDisplays average value of memorized data ( value) CDisplays value of memorized data 3 (3 value) CDisplays 3±% value of memorized data CP (CP value) CDisplays CP value of memorized data CDisplayed value is calculated one from the selected work number setting value (torque high and low limit value) CPK (CPK value) CDisplays CPK value of memorized data CDisplayed value is the calculated one from the selected work number setting values (torque high and low limit value). Note: All the above mentioned values, average value, value, 3 value, CP value and CPK value, are the calculated ones, not the setting values.
& MEMORY DATA BLOCK (former name: MODE 87) Default: 3 Setting : 1 UEC stores data of work number all in one without time/date and ID number. (Maximum 12,000 pcs.) Setting : 2 UEC stores data per work number without time/date nor ID number. (Maximum 1,500 pcs.) Setting : 3 UEC stores data of work number all in one including time/date, but without ID number. (Maximum 5,400 pcs.) Setting : 4 UEC stores data per work number including time/date, but without ID number. (Maximum 680 pcs.) Setting : 5 UEC stores data of work number all in one including time/date and ID number. (Maximum 2,200 pcs.) Setting : 6 UEC stores data per work number including time/data and ID number. (Maximum 270 pcs.) ]Function^ This is to determine whether per work number or work number 1 -8 all in one, and whether include time/data and ID number UEC stores the data. CWhen the data is stored per work number, the storable maximum data becomes 1/8 of the one stored by batch. UEC drops old data to memorize new data one by one after the storage comes to the maximum. CWhen the data is stored with time/date, the storable maximum data becomes approx. 1/2. CUEC calculates average value, CPK value etc. per block. MEMORY DATA CONTENTS (former name: MODE 88) Default: 0 Setting: 0 Not memorize the fastening data Setting: 1 Memorize all fastening data UEC provides warning (memory level warning) when the data storage comes to another 10 pieces to maximum memory. Switch on RESET terminal, or press , and the display will go off. But UEC provides warning, if you continue fastening. Setting: 2 memorize all fastening data, but not warn maximum memory. Setting: 3 Memorize only OK data and warn maximum memory. Setting: 4 Memorize only OK data, but not warn maximum memory. ]Function^ CThis is to determine what to memorize and whether warn maximum memory when the data storage comes to another 10 pieces to maximum memory. CAll memorized data is cleared when the setting value is changed. UNUSUAL HISTORY CLR ]Function^ CEnter 1 to clear the error data points messages stored in UEC-4800TP.
& Statistics Data UEC calculates the memorized data and displays [N] (number of data) of fastening data, average value, [] (standard deviation), 3/Average value (scatter), [CP] (process capability index), [CPK] (unilateral process capability index) and [RANGE] (torque low limit – torque high limit). When either 2 or 4 are set to MEMORY DATA BLOCK, UEC displays the data per work number 1 – 8. When either 1 or 3 is set to MEMORY DATA BLOCK, UEC displays all data in WORK 1. Maximum [N] is 12,000 data.
&% Former data (raw data) UEC displays memorized data of Torque, Pulse number, fastening time and judgment. Maximum data which can be displayed on 1 page is 10 pieces. Touch or to have another 10 data scrolled up or down. When either 2 or 4 are set to MEMORY DATA BLOCK, fastening data is displayed per work number. Touch in right upper of a screen, and work number is changed to other like 1 2 with data display of each work number. When either 1 or 3 is set to MEMODY DATA BLOCK, all fastening data is displayed on work number 1 all in one. (Maximum [N] is 12,000 data.)