Home > Aimco Brakes > Monitors > Aimco Brakes Monitor UEC4800TP Instruction Manual

Aimco Brakes Monitor UEC4800TP Instruction Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Aimco Brakes Monitor UEC4800TP Instruction Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 85 Aimco Brakes manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							21. Error Proofing  
    21.1 Barcode Reader  
    The max length of a barcode is 20 characters if it is longer the  leading characters will be lost and the last 
    20 will be used.  Since barcode readers send their characters in burst there is no need to program in a 
    length.  The software just waits for the reader to stop sending.  Once the barcode is read the results are  
    stored as the VIN.  
    21.2 VIN Pattern Matching 
    All new VINs from barcode readers,  Profibus,  DeviceNET,  Ethernet/IP  or protocols are checked against 
    for a  VIN match against each PSET (starting from #1 and through #8).  If a match is found the PSET is 
    changed.   In order to qualify as a match the received barcode must be at least as long as the match string.  
    The match string can contain “don’t care” characters (‘.’) as a wild card.  In the example below a barcode 
    of “Abc123” selects PSET #1, “abc567” selects PSE T #2, “def” selects PSET #4, “ABc” selects PSET #5, 
    and “AB” does nothing. 
     
    22.  Setting the time 
    UECs with a real -time clock can have  the time set through the web,  Open Protocol, or sync to a ToolsNet 
    server . 
    22.1  From the web interface  
      Open the web browser from a  PC and type the controller IP address into the address bar.  
       Navigate to the ‘Time’ page.  The current values for the time and date are displayed.  
       Replace the values for time and date and click ‘Set time’.   
    22.2 From the Open protocol interface  
      See the Open Pro tocol section for how to connect to the controller with this interface  
    22.3 From a ToolsNet server 
      The time will automatically sync when connected to a ToolsNet server   
    						
    All Aimco Brakes manuals Comments (0)