39                              © Adam Equipment Company 2013 
 
CALIBRATION 
·  The  GK  indicator  can  be  calibrated  using  kilogram  w eights  or  using 
pounds weights, depending on the weighing unit sele cted at the time of 
calibration. 
  ·   To  start  the  calibration,  either  get  into  the  calib ration  section  through 
the  Indicator  Settings  ( “FUnC 3”-  see  Section  13.3)  or  turn  the  indicator 
off and switch on again and then press  [Tare] during the self-test.  Enter 
code...

Page 42

 
40                              © Adam Equipment Company 2013 
PARAMETER SETTINGS 
Pressing the [Func] key allows the user to access the parameters for cu stomising the 
indicator. The parameters are split into 4 groups-   
  
1. Check weighing parameters,  
2. RS-232 parameters  
3. Indicator parameters 
4. Percent and Animal Weighing Functions  
·  When  [Func]  is  pressed,  display  will  first  show   “FUnC  1” for  Check  weighing 
parameters.  
 
·  Enter  [2]  for  RS-232  parameters  or   [3]...

Page 43

 
41                              © Adam Equipment Company 2013 
·  Press  [Func]  to view the options for setting.  
 
·  Press   [Tare]  to  confirm  the  change  and  then  advance  to  the  next  parameter 
by pressing the  [Func] key. 
  
This group of parameters- 
-   enables or disables the percent weighing  
-   sets the lock for re-setting the check weighing  limits 
-   enables or disables the check weighing LED indi cator 
-   enables or disables the check weighing alarm  
-   sets the User...

Page 44

 
42                              © Adam Equipment Company 2013 
  
F2  LEd This parameter sets the LED  
indicator to off or on and the 
LED type (whether LED’s are 
on in the form of a  
continuous bar or a spot LED  
or a segment of colour).
 bAr
    -  Bar type  
Spot   - Spot type  
Seg   
-   Segment  
oFF      -  Off 
  bAr
 
F3  bEP  This parameter sets the  
Beeper to off or on. If set to 
on, the beeper can further 
be set to sound when the  
weighing result is within or  
outside the...

Page 45

 
43                              © Adam Equipment Company 2013 
  
1.14.  RS-232 PARAMETERS 
 
·  Shortcut to enter this group is to press and hold t he [Print]  key for 4 seconds. 
The display will go directly to  “C1   on”.  
 
·  Press  [Func]  to view the list of parameters.  
 
·  Press  [Tare]  to  enter  a  parameter.  Press   [Func] to  view  the  options  for  the 
parameter settings.  
 
·  Press  [Tare]  to  confirm  the  change  and  then  advance  to  the  next  parameter 
by pressing the...

Page 46

 
44                              © Adam Equipment Company 2013 
  
C3 PrM 
Printing Mode- Manual as  
soon as stable,   
Manual as soon as the key  
is pressed stable or not,   
Automatic As soon as  
stable  
Automatic when weight is  
removed  
Continuous only when  
stable  
Continuous at any time,  
stable or not  mA  StA   
*mA  AnY  
*Au  StA  
Au End   
*Ct StA  
*Ct Any  
*Not an option on  
EC approved scales 
 
mA Sta  
C3 PrM Printing Mode- Manual,  
Continuous or Automatic mAn,  
Cont 
(not...

Page 47

 
45                              © Adam Equipment Company 2013 
  
The  indicator  will  perform  the  following,  depending   on  the  Accumulation  and  Print 
Settings: 
 
ACCUMULATION  SETTINGS
 
PRINT SETTINGS 
AC on AC Off 
mA StA 
 
Accumulate and Print as soon  
as  the   [Print] key is pressed. 
 
If the  [Print]  key is pressed a 
second time print only,  
accumulation will only occur  
if scale returns to zero first.  Print as soon as the 
[Print] key is 
pressed, and the scale is stable....

Page 48

 
46                              © Adam Equipment Company 2013 
Au End  
 
Accumulate and print when  
the scale has reached  
stability after  the weight is  
removed.   
If the   [Print]  key is pressed it 
is ignored.    Print after the scale is stable and the  
weight has been removed.  
If the 
 [Print]  key is pressed it is 
ignored.   
Do not accumulate. 
Ct StA 
Not  available  on  
approved indicators 
Print continuously if the scale  
is stable.  
Accumulate immediately  
when  [Print]  key is...

Page 49

 
47                              © Adam Equipment Company 2013 
1.15.  INDICATOR PARAMETERS  
 
·  Shortcut  to  enter  this  group  is  to  press  and  hold  t he  [Count]   Key  for  4 
seconds. The display will go directly to “S1    Un   ”.  
·   Press  [Func]  to view the list of parameters.  
·   Press  [Tare]  to  enter  a  parameter.  Press  [Func] to  view  the  options  for  the 
parameter settings.  
·   Press  [Tare]   to  confirm  the  change  and  then  advance  to  the  next   parameter...

Page 50

 
48                              © Adam Equipment Company 2013 
 
S3  AoF  Auto Off- Disable or set  
time increment to turn off  
the indicator  SLP   0  
SLP   1  
SLP   5 
SLP   10
  SLP   0   
S4   dt  Set Time and Date format  
and settings  Enter the time  
manually  
Enter the date  
manually
  00:00:00  
mm:dd:yy
 
S5  diS  Display all weights or only  
when stable    ALL 
StAb   ALL 
 
S6  Fi  Filter setting to slow,  
normal or fast  SLow  
nor  
FASt
  nor   
S7 SPS  Scale Password- If it is...