Adam Equipment GK Indicator GKREVL1 User Manual
Have a look at the manual Adam Equipment GK Indicator GKREVL1 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Adam Equipment manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
39 © Adam Equipment Company 2013 CALIBRATION · The GK indicator can be calibrated using kilogram w eights or using pounds weights, depending on the weighing unit sele cted at the time of calibration. · To start the calibration, either get into the calib ration section through the Indicator Settings ( “FUnC 3”- see Section 13.3) or turn the indicator off and switch on again and then press [Tare] during the self-test. Enter code number 0000 and press [Tare]. This will take you directly to the calibration section. · The display will show "UnLoAd" · Remove all weight from the platform and then press the [Tare] key when the display is stable. After the Zero point is set, the display will show “Ld xx” . Place the suggested calibration mass on the platf orm. It is best to use a weight close to the full capacity of the indicator. If the mass is different from the displayed value, enter t he value of the mass in whole numbers. The kg or the lb symbol will be o n to show the active unit. · Press the [Tare] key when the stable indicator is on. · The indicator will calibrate to the mass. When comp lete, it will display “PASS” and then either display “S8 CAL” (if entered the calibration section through the Indicator Settings as per secti on 13.3) or return to normal weighing (if entered directly). Remove the c alibration mass. · If an error message “FAIL H” or “FAIL L” is shown, re-check the calibration and repeat. If the error cannot be corrected contac t your supplier.
40 © Adam Equipment Company 2013 PARAMETER SETTINGS Pressing the [Func] key allows the user to access the parameters for cu stomising the indicator. The parameters are split into 4 groups- 1. Check weighing parameters, 2. RS-232 parameters 3. Indicator parameters 4. Percent and Animal Weighing Functions · When [Func] is pressed, display will first show “FUnC 1” for Check weighing parameters. · Enter [2] for RS-232 parameters or [3] for Indicator parameters or [4] for percent weighing and animal weighing, or press t he [Func] key to advance through the groups “FUnC 1”, “FUnC 2” , “FUnC 3” and “FUnC 4” . Press [Tare] to enter the desired group of parameters. · Press [Zero] to return to the group “FUnC 1”. If you press [Zero] again, the indicator will exit the User Parameter section and return to normal weighing. 1.13. CHECK WEIGHING PARAMETERS · Shortcut to enter this group is to press and hold t he [Unit] key for 4 seconds. The display will go directly to “FUnC 1”. · Press [Tare] to enter the group. · Press [Func] to scroll through the parameters and press [Tare] to enter a parameter setting.
41 © Adam Equipment Company 2013 · Press [Func] to view the options for setting. · Press [Tare] to confirm the change and then advance to the next parameter by pressing the [Func] key. This group of parameters- - enables or disables the percent weighing - sets the lock for re-setting the check weighing limits - enables or disables the check weighing LED indi cator - enables or disables the check weighing alarm - sets the User Password for check weighing enables or disables the negative check weighing Parameter Description Options Default setting F1 LLk This parameter prevents the normal user from changing the limits with the help of a Limit Lock. With LLK set to Off (oFF), the user is allowed to change limits at any time. With LLK set to Preset (PSt), the user is allowed to use one of the preset limits only. oFF
42 © Adam Equipment Company 2013 F2 LEd This parameter sets the LED indicator to off or on and the LED type (whether LED’s are on in the form of a continuous bar or a spot LED or a segment of colour). bAr - Bar type Spot - Spot type Seg - Segment oFF - Off bAr F3 bEP This parameter sets the Beeper to off or on. If set to on, the beeper can further be set to sound when the weighing result is within or outside the check-weighing limits. bP oFF - Off bP inL - Within limits bP otL - Outside limits (>20d) bP inL F4 CPS This parameter allows setting of a new Check weighing password, must be entered twice when asked. When complete, it will display “donE”. To be entered manually. 0000 F5 nCK This parameter enables negative check weighing function with ability to do negative tare. on oFF on NOTE: 1. The Check weighing password is separate from the in dicator password, see section 13.3. 2. If the password is other than 0000, user must enter the password to gain access to “F3 LLk”, “F4 LEd” , “F5 bEP” , “F6 CPS” and “F7 nCK” .
43 © Adam Equipment Company 2013 1.14. RS-232 PARAMETERS · Shortcut to enter this group is to press and hold t he [Print] key for 4 seconds. The display will go directly to “C1 on”. · Press [Func] to view the list of parameters. · Press [Tare] to enter a parameter. Press [Func] to view the options for the parameter settings. · Press [Tare] to confirm the change and then advance to the next parameter by pressing the [Func] key. · Press [Zero] to return to the group “FUnC 2”. If you press [Zero] again, the indicator will exit the User Parameter section and return to weighing. This group of parameters can be set by the user for setting the language, baud rate, printing mode, etc. The user can also set a Scale ID number and a User ID number. Parameter Description Options Default Values or setting C1 on Enable or disable the RS- 232 interface Prt on Prt oFF Prt on C2 bd Baud Rate 600 1200 2400 4800 9600 19200 9600
44 © Adam Equipment Company 2013 C3 PrM Printing Mode- Manual as soon as stable, Manual as soon as the key is pressed stable or not, Automatic As soon as stable Automatic when weight is removed Continuous only when stable Continuous at any time, stable or not mA StA *mA AnY *Au StA Au End *Ct StA *Ct Any *Not an option on EC approved scales mA Sta C3 PrM Printing Mode- Manual, Continuous or Automatic mAn, Cont (not on EC approved scales) AUto mAn C4 Aon Enable or disable the Accumulation AC on AC oFF AC on C5 Ln Select Language EnGLi (English) FrEnCH (French) GErmAn (German) SPAn (Spanish) EnGLi C6 UId Set User ID To be entered manually 000000 C7 Sid Set Scale ID To be entered manually 000000 C8 Lab Set the print format to be a label as shown (ON) or a single line (Off) Lab On Lab Off Lab On
45 © Adam Equipment Company 2013 The indicator will perform the following, depending on the Accumulation and Print Settings: ACCUMULATION SETTINGS PRINT SETTINGS AC on AC Off mA StA Accumulate and Print as soon as the [Print] key is pressed. If the [Print] key is pressed a second time print only, accumulation will only occur if scale returns to zero first. Print as soon as the [Print] key is pressed, and the scale is stable. Do not accumulate. mA Any Not available on approved indicators Accumulate and Print as soon as the [Print] key is pressed. Even if the scale is unstable. If the [Print] key is pressed a second time print only, accumulation will only occur if scale returns to zero first. Print as soon as the [Print] key is pressed, Stable or not. Do not accumulate. Au StA Not available on approved indicators Accumulate and print automatically as soon as scale becomes stable. If the scale goes unstable and then stable again print the new stable value. But do not add to Accumulation. If the [Print] key is pressed at any time the scale is stable print only. Accumulation will only occur if scale returns to zero first. Print as soon as the scale is stable. If the scale goes unstable and then stable again print the new stable value. If the [Print] key is pressed print again. Do not accumulate.
46 © Adam Equipment Company 2013 Au End Accumulate and print when the scale has reached stability after the weight is removed. If the [Print] key is pressed it is ignored. Print after the scale is stable and the weight has been removed. If the [Print] key is pressed it is ignored. Do not accumulate. Ct StA Not available on approved indicators Print continuously if the scale is stable. Accumulate immediately when [Print] key is pressed if the scale is stable. Print continuously if the scale is stable. Do not accumulate. Ct AnY Not available on approved indicators Print continuously, stable or not. Accumulate when the [Print] key is pressed stable or not. Print continuously stable or not. Do not accumulate. Note: Manual Printing is allowed at zero only when the scale is stable. If set to Auto the scale will not automatically print when it retu rns to zero. On EC approved scales printing is not allowed less than 20 divisions. Accumulation is only allowed if the weight is great er than 20 divisions.
47 © Adam Equipment Company 2013 1.15. INDICATOR PARAMETERS · Shortcut to enter this group is to press and hold t he [Count] Key for 4 seconds. The display will go directly to “S1 Un ”. · Press [Func] to view the list of parameters. · Press [Tare] to enter a parameter. Press [Func] to view the options for the parameter settings. · Press [Tare] to confirm the change and then advance to the next parameter by pressing the [Func] key. · Press [Zero] to return to the group “FUnC 3”. If you press [Zero] again, the indicator will exit the User Parameter section and return to normal weighing. This group of parameters are used to control the op eration of the indicator. Parameter Description Options Default setting S1 Un Enable or disable weighing units, Not all units are available for all scales settings. Only USA scales have imperial unit. kg g lb oz lb:oz kg S2 bL Backlight set to always on, always off or automatic on whenever a weight is placed or a key is pressed EL oFF EL on EL AU EL AU
48 © Adam Equipment Company 2013 S3 AoF Auto Off- Disable or set time increment to turn off the indicator SLP 0 SLP 1 SLP 5 SLP 10 SLP 0 S4 dt Set Time and Date format and settings Enter the time manually Enter the date manually 00:00:00 mm:dd:yy S5 diS Display all weights or only when stable ALL StAb ALL S6 Fi Filter setting to slow, normal or fast SLow nor FASt nor S7 SPS Scale Password- If it is anything other than 0000 then the user must enter the password to gain access to any of the indicator parameter settings. Must be entered twice when asked. When complete, it will display “donE” . PI _ _ _ _ 0000 S8 CAL Calibration Calibrate the indicator to a platform. See Section 10.0 -