Home > Adam Equipment > Indicator > Adam Equipment GK Indicator GKREVL1 User Manual

Adam Equipment GK Indicator GKREVL1 User Manual

Here you can view all the pages of manual Adam Equipment GK Indicator GKREVL1 User Manual. The Adam Equipment manuals for Indicator are available online for free. You can easily download all the documents as PDF.

Page 21

 
19                              © Adam Equipment Company 2013 
 
     
 
 
 
                        
 
    
                        
 
 
·   To  count  a  different  sample  quantity,  press  the   [Count]  key.  The  display 
will  show  the  last  used  sample  size.    Either  use  th is  sample  size  with  a 
different part or enter a new sample size as above.   
 
·  To return to weighing, press  [Unit] when  “XX pcs”  is displayed.     

Page 22

 
20                              © Adam Equipment Company 2013 
1.7.  CHECK-WEIGHING 
 
Check-weighing is a procedure to display an indicat or or sound an alarm when 
the  weight  on  the  platform  meets  or  exceeds  the  val ues  stored  in  the 
memory.  The memory holds values for a high limit a nd a low limit.  Either or 
both the limits can be set by the user.    
NOTE:   
1. The alarm and the LED bargraph can each be set t o OFF (See section 13.1). 
The LCD display will indicate whenever the...

Page 23

 
21                              © Adam Equipment Company 2013 
 
1.7.1   SETTING UP WHILE WEIGHING 
 
·  Press  the   [Low  Limit]  key.  It  will  show  the  current  low  limit.  The  “LO” 
symbol will appear on the display. 
 
·  Press  the  [CE] key  to  clear  the  old  value  and  then  enter  the  new  l ow 
limit  using  the  numeric  keys.  The  decimal  point  is  fixed  at  the  position 
that  is  used  for  the  current  weighing  unit.  When  th e  desired  value  is 
shown press  [Tare]...

Page 24

 
22                              © Adam Equipment Company 2013 
 
1.7.2  SETTING UP WHILE PARTS COUNTING OR % WEIGHING 
    
During  parts  counting  and  percent  weighing  the  limi ts  are  set  in  the  same  way  as 
above. The limits are displayed in pcs or %.    
See  Section  10.4  for  the  description  of  parts  count ing  and  Section  10.7  for  percent 
weighing.    
NOTE:  
 
1.  T he  weight  must  be  greater  than  20  scale  divisions  f or  the  check-
weighing to operate.   
  
2....

Page 25

 
23                              © Adam Equipment Company 2013 
 
 
 
 
  Press  the
  [


Lim]   key.      If  you  are  already  in 
the check weighing mode the display will ask  
if  you  wish  to  store  the  current  limits  by  
showing  “StOrE” or recall another set of limits 
by  showing  “rECALL”.  The [


Lim]   key  can  be 
used to toggle between  “StOrE” and “rECALL”.  
 
 
 
 
   
  I
f  you  want  to  store  the  limits,  when  “StOrE” 
is  displayed  press  the  [Tare]  key.  The...

Page 26

 
24                              © Adam Equipment Company 2013 
NOTE:    
1. If the recalled limit is for parts counting, the di splay will show the last sample 
value used, ready for a new sample to be counted.    
 
2. If  the  recalled  unit  is  a  percent  weighing  limit,  t he  display  will  show  the  last 
sample value used, ready for a new sample to be wei ghed.   
 
3. If the memory location was empty the indicator will  return to weighing.  
 
 
1.9.   PERCENT WEIGHING  
 
The indicator can...

Page 27

 
25                              © Adam Equipment Company 2013 
·  Press  [Tare]  again to enter percent weighing. The indicator wil l set the sample 
mass on the platform as 100% reference weight.   
 
NOTE:  If  there  is  no  reference  weight  on  the  pan  and  perc ent  weighing 
function  is  entered,  pressing  [Tare]  again  will  return  the  indicator  to  normal 
weighing. 
     
 
 
 
·  Remove  the  sample  weight.    Then  any  other  weight  pl aced  on  the  platform 
will  be...

Page 28

 
26                              © Adam Equipment Company 2013 
·  If the indicator shows  “x x . x x %”, which is the last weight used as a reference, 
press   [CE]  to  clear  and  use  the  numeric  keypad  to  enter  a  new   value.    Press 
[Tare]  to accept the new reference weight.    
 
·  The weight entered must be greater than 50 scale di visions.   
   
·  Press  [Unit]  to return to normal weighing. 
  
NOTE:   
The  display  may  jump  by  large  numbers  unexpectedly  if  small  weights...

Page 29

 
27                              © Adam Equipment Company 2013 
1.10.  ANIMAL (DYNAMIC) WEIGHING  
The  indicator  can  be  set  to  animal  (dynamic)  weighi ng  for  weighing  any  items  that 
are unstable or may move.    See Section 13.4.  
The indicator  uses a  special filter to minimise the   effects of any   movement   on  the 
platform.   
  
·  Press  [Func] . The first option is  “FUnC 1”, press the  [Func] key 3 more times to 
display  “Func 4” .  
 
 
·   Press  the   [Tare] key. “F4  PCt”...

Page 30

 
28                              © Adam Equipment Company 2013 
1.10.1  A NIMAL WEIGHING PROCEDURE 
 
·  With the platform empty the display will show zero  weight..  Place containers 
or  blankets  onto  the  platform  and  press  the   [Tare] key  to  zero  the  display.   
The indicator may go into the animal weighing proce dure when the items are 
placed on the platform but will return to showing z ero when the [Tare] key is  
 
·  Place the animal to be weighed on the platform.    
 
·  When  a...
Start reading Adam Equipment GK Indicator GKREVL1 User Manual