Page 61
STARPLUS@ si=D 4896 Digital Key Telephone SystemKEY STATlON FEATURE DESCRIPTION 200.108 PAGE/RELAY CONTROL The Starpius Digital Key Telephone System offers relays that may be individually programmed for: External Page, Loud Bell Control, CO Line Control, Power Failure Transfer, and Recorded An- nouncement uses. Up to four Relay/Sensor interfacemodules may be installed on the system. Each re- lay/sensor interface module contains three inde- pendent relays and three sensing input circuits. 200.109...
Page 62
KEY STATlON FEATURE DESCRlPTlON *ARPLUS@ SPD 4896Digital Key Telephone System 6. Per Station Option Each station may be programmed to give the station the capability to join an existing conver- sation simply by pressing the CO line button that is in use. A programmable warning tone is presented to all parties when the station entersthe conversation. The CO line must also have privacy disabled to allow the cut-thru. 200.116 PRIVATE LINE Private line programming allows certain lines to ringat a specific...
Page 63
STARPLUS@ SPD 4896 Digital Key Telephone SystemKEY STATION FEATURE DESCRIPTION 200.122SAVE NUMBER REDIAL (SNR) Any number dialed on an outside line can be saved permanently to be used at any time. This number is saved until a new number is stored. 200.123SINGLE LINE TELEPHONE (SLT)COMPATIBILITY The Starplus Digital Key Telephone System sup- ports industry standard 2500 Type (DTMF) single line instruments. When the Single Line Telephone Board (SL12) is installed, a maximum of 12 single line telephones...
Page 64
KEY STATlON FEATURE DESCRIPTION STARPLUS@ SPD 4896 Digital Key Telephone Systemsponse text (LCD) messages. The text messages appear on the calling party LCD display. The calling (originating) station and receiving station MUST be a digital terminal. The receiving station MUST also be programmed to allow OHVO calls. 200.133 TOLL RESTRICTION (TABLE DRIVEN)The system provides a flexible means of providing toll restriction to internal stations of the StarplusDigital Key Telephone System. Each station is...
Page 65
STARPLUS@ SPD 4696Digital Key Telephone SystemKEY STATlON FEATURE DESCRIPTION the status of their UCD group. This display is anidle state display and will prompt a supervisor that Agents in a group are having problems answering all their calls. The display will tell the agent and his supervisor how many calls are inqueue, how many agents are available or logged into the group, and the length of time in minutes that the oldest call has been in queue. The agent will receive the calls in queue...
Page 66
KEY STATlON FEATURE DESCRlPTlON *AFtPLUS@ SPD 4696 Digital Key Telephone System D. E. F.such a button has not been programmed, a voice mail message waiting indication will ap- pear on the MSG WAIT button as a normal message waiting signal. VM Tone Mode Calling OptionVoice mail systems and/or Automated Atten- dants can utilize the Calling Station Tone Modeoption. This is useful when using supervised transfer or call screening options on voice mail or auto attendant(s) requiring ring back tone forproper...
Page 67
Table 210-I SLT Station Features/Software PaCkayes .___-__-__--__------ FEATURE __--~--___-A Account Code . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210-l~-Automatic Line Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210-l~- c CallForward. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lLllll . . . . . . . . . . 210-l- Camp-On . . . . . . ....
Page 69
STARPLUS @ Si=D 48%Digital Key Telephone SystemSINGLE LINE TELEPHONE FEATURE DESCRIPTION SECTION 210 SINGLE LINE TELEPHONE FEATURE DESCRIPTIONSingle Line telephones have access to most of the system and station features listed in the previous section, however, the additional features listed be- low are unique to Single Line Telephones. The Sin- gle Line Telephone Board (SL12) is required in the Starpius SPD 4896 System for proper SLT opera- tion. A Single Line Adapter (OPX) box and 48vPower Supply may...
Page 70
STARPLUS ’ SPD 4696 SINGLE LINE TELEPHONE FEATURE DESCRlPTlONDigital Key Telephone System 210.12 HANDSET RECEIVER GAIN This feature allows an SLT user while on a CO call to hookflash and dial a code to increase/decrease the handset volume. 210.13 INTERCOM CALLING Single line telephones can make and receive inter- com calls.210.14 LOOP INTERRUPT OPTIONThis feature allows Single Line telephone ports to provide a Loop Disconnect signal to any devices thatare connected to an SLT port. This is an inherent...