Home > Vodavi > Telephone > Vodavi Starplus 96ex Hybrid Key Telephone System Installation Manual

Vodavi Starplus 96ex Hybrid Key Telephone System Installation Manual

Here you can view all the pages of manual Vodavi Starplus 96ex Hybrid Key Telephone System Installation Manual. The Vodavi manuals for Telephone are available online for free. You can easily download all the documents as PDF.

Page 101

sTARPLUS@ 96EX 
Key Telephone System 
NORMAL 
SERVICE 
0 , 4 E 
0 
5 II 
0 6 ’  WHITE 
COLORED 
Figure 500-9 Central Office interface Board (COB) 
500-l 2 
Issue 1, June 1991  

Page 102

BARPLUS@ 96EX Key Telephone System 
Table 500-3 P-l Connecting Block 
PAIR 
1 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23 
24 
25 Table 500-4 P-2 Connecting Block 
PIN 
-28 
1 
27 
2 
28 
3 
29 
4 
30 
5 
31 
6 
32 
7 
33 
8 
34 
9 
35 
10 
36 
11 
37 
12 
38 
13 
39 
14 
40 
15 
41 
16 
42 
17 
43 
18 
44 
19 
45 
20 
46 
21 
47 
22 
4% 
23 
49 
24 
50 
25 COLOR DESIG DESCRF 
L WH/BL CO 25T 
BU’JVH CO 25R 
WHQR CO 26T 
OR/“NH CO 26R 
co 27T  WH@N 
GNPNH CO 27R C 
WHhN...

Page 103

. 
Key Telephone System 
NORMAL 
SERVICE 
0 
0 ? 
6 
Odb 
3db 
Odb 
co 3 
3bd 
@!5 
Odb 
if!!5 co 4 
3db 
Odb 
co 5 
3db 
@!!3 
Odb 
@!3 CO 6 
3db 
Odb 
@!!F3 co 7 
3db 
Odb 
3db  WHITE 
COLORED 
Figure 5OGlO Amplified CO Interface Board (COA) 
500-14 Issue 1, June 1991  

Page 104

sTARPLUS@ 96EX Key Telephone System 
ORMAL 
ERVICE 
0 
GREEN 
COLORED 
50-PIN 
STATION 
CONNECTOR 
Figure 500-11 Key Station lntetface Board (KIB) 
Issue 1, June 1991 500-15  

Page 105

sTARPLUS@ 96EX Key Telephone System 
Table 500-5 Station Connecting Block (KIB) 
PAIR 
I 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23 
24 
25 PIN 
26 
I 
27 
2 
28 
3 
29 
4 
30 
5 
31 
6 
32 
7 
33 
L 
9 
35 
10 
36 
11 
37 
12 
38 
13 
39 
14 
40 
15 
41 
16 
42 
17 
43 
18 
44 
19 
45 
20 
46 
21 
47 
22 
48 
23 
49 
24 
50 
25 COLOR 
WH/BL 
BUWH 
WH/OR 
OR/WH 
WH/GN 
GN/WH 
WH/BN 
BN/WH 
WH/SL 
SUWH 
RD/BL 
BURD 
RD/OR 
OR/RD 
RD/GN 
GNfRD 
RD/BN 
BN/RD 
RD/SL 
SURD...

Page 106

Table 500-6 Power Failure Transfer Unit 
Connections(PFT) 
PAIR 
1 
2 
3 
4 
5 
6 
7 
8 
9 
IO 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23 
24 
25 PIN COLOR 
26 WH/BL 
1 BUWH 
27 WH/OR 
2 OFUWH 
28 WH/GN 
3 GN/WH 
29 WH/BN 
4 BN/WH 
30 WH/SL 
5 SUWH 
31 RD/BL 
6 BURD 
32 RD/OR 
7 OFURD 
33 RD/GN 
8 GN/RD 
34 RD/BN 
9 BN/RD 
35 
RD/SL 
10 SURD 
36 BK/BL 
11 BUBK 
37 BK/OR 
12 
OR/BK 
38 BK/GN 
13 
GN/BK 
39 BlVBN 
14 BN/BK 
40 BKISL 
15 SUBK 
41 
YUBL 
16 BUYL 
42 YUOR 
17 
OFUYL 
43 WGN 
18 GN/YL...

Page 107

S-rARPLlJS@ 96Ex Key Telephone System 
CO1 TIP IN 
------------------------.-------------------------------------------------- 
CO1 RING IN 
-------------------------i---------y --------------------------------------- 
SPARE 
STAl TIP Om 
~------------------------------------------------------ 
STAl RING OUT 
!----------------------------------------------- 
STAl RING IN 
EQ”&NT 
SCREW 
TERMINN POWER FAILURE TRANSFER 
- ORJW 
- WIGN 
=i.+J 
- ww L 
LEC CONTACT 
NOTE: C-mwction to SIB interface is...

Page 108

E. Connect the customer provided ringing gener- 
ator and ringing devices(s) to the LBC contacts 
(Refer to Figure 500-12). 
F. Replace the plastic terminal strip protector. 
500.14 KEY TELEPHONE INSTALLATION 
A maximum of 96 Key Telephones may be installed 
with the Starplus 96EX Hybrid Key Telephone Sys- 
tem (48 with the Basic KSU and 48 with the Expan- 
sion KSU). The Key Telephones are interfaced with 
KIB boards which each have eight circuits per board. 
Each KIB circuit interface is extended from...

Page 109

. 
GREEN ~ 
RED VR 
DT 
DR 
I 1 
Key Telephone Wiring 
GREEN ~ 
‘ED VR 
Single tine Telephone Wiring GREEN 
RED - VT 
I 
J 
DSSIDLS Console Wiring 
GREEN 
, 
RED 
BLACK 
YELLOW 
~zqq 
BLK YEL REDGRN 
Phone Box Wiring 
Figure 500-13 Station Modular Block Wiring 
VT 
VR 
DT 
DR 
500-20 Issue 1, June 1991  

Page 110

L 
Each SLT requires one-pair cab!e. The cable shou!d 
be placed from the telephone location to the MDF in 
a “home run” manner. The telephone end of the 
cable run should be terminated in a modular jack 
(Refer to Figure 500-13). The MDF end should be 
“punched down” on a terminal block for cross con- 
nection to the appropriate station cable (Refer to 
Table 500-7). 
500.18 OFF-PREMISE EXTENSION INSTAL- 
LATION (OPX) 
The OPX board can be installed in all but the first 
KIB card slot of the System. It...