STARPLUS@ 616 FLEX KEY TELEPHONE SYSTEM 
DO NOT PLUG IN THE POWER CORD AT 
THIS TIME 
500.5 KSU CABLING 
Two (2) Amphenol-type connectors are provided on 
the left side of the KSU (Refer to Figure 400.3). 
On the right edge of the front surface are the RJI 1 C 
connectors which are for CO lines. On the left side 
surface of the 616 FLEX KSU are two connectors 
marked J-l and J-2. The J-l connector is located just 
below the J-2 connector. J-l and J-2 require 90 
degree male ended plug cables for proper...

Page 52

STARPLUS@ 616 FLEX KEY TELEPHONE SYSTEM 
The Phone Box consists of a top housing and bottom 
mounting plate. The top housing has a speaker, 
microphone, wire terminals and electronic circuitry. 
The housings are separated by inserting a thin, 
flat-edged tool at the bottom rim of the assembly. By 
pressing inward on the recessed retaining tab, the 
assembly will open. 
The connection of the Phone Box(es) to the KSU is 
identical to that of the key telephone. Refer to Figure 
500.8 
The bottom plate of...

Page 53

STARPLUS@ 616 FLEX KEY TELEPHONE SYSTEM 
Environment Connections 
Temperature: 0 - 50 C (32 - 104 F) 
Humidity: 0 - 95% 
C. Installation 
Introduction 
These instructions cover installation procedures for 
the BBU. Refer to Figure 500.6 for the location of the 
input socket. The input socket of the key system 
must be a female Mate-N-Lok type connector. 
Installation Checklist Remove the BBU cover by turning the 4 screw 
locks and lifting the cover. 
Install the two 12 V DC batteries in the battery...

Page 54

STARPLUS@ 616 FLEX KEY TELEPHONE SYSTEM 
E. Maintenance 
In order to ensure proper operation of the battery 
supply, the following operation should be performed 
once a month: 
A. Unplug the key system and the battery back up 
unit from the AC power to allow operation from 
the batteries for 15 minutes. 
B. Plug the key system and BBU power cord back 
into the AC outlet. 
F. Troubleshooting 
When trouble is reported, verify that AC power is 
being supplied to the unit and that there are no blown 
fuses....

Page 55

I. 
Insert the pins on the bottom of the R.C.U. into 
the R.C.U. socket (G22) being careful to align 
all of the pins with the socket. Apply pressure 
in the middle of the R.C.U. (not the ends) to 
avoid breakage while seating the R.C.U. into 
the socket. Replace KSU cover. R.C.U. instal- 
lation is now complete. 
500.19 SERIAL INTERFACE UNIT (SIU) MQD- 
ULE INSTALLATION 
A. Turn OFF the KSU power by removing the plug 
from the AC outlet. 
B. Remove the Program Module from the KSU. 
C. Unscrew the six...

Page 56

STARPLUS@ 616 FLEX KEY TELEPHONE SYSTEM 
500.22 POWER-UP AND INSTALLATION 
CHECKUST 
Prior to actual power-up and initialization, the key 
system should be checked over to avoid start up 
delays or improper loading. A step-by-step checklist 
is provided for this purpose: 
A. 
B. 
C. 
D. 
E. Ensure that the KSU is properly grounded ac- 
cording to the instructions in Sec. 500.3. 
Inspect the MDF for shorted wiring or improper 
polarity that would affect the Key telephones. 
Make sure that plug-ended MDF...

Page 57

STARPLUS@ 616 FLEX 
KEY TELEPHONE SYSTEM 
18.00 13. (-12.75 A 
L- 12.00” 
lllllIll /Illll/I I/llllI/ /I/lj/ll Ill 
Ill 
STARPLUS 
El 
616 FLEX 
/II IllI II //Ill IllI II llllllll I/II/Ill 
DEPTH:3.00 
Figure 500.1 - KSU Mounting Dimensions 
‘mns ICCIIC i IANIIAPV IQ01  

Page 58

sTARPLUS@ 616 FLEX KEY TELEPHONE SYSTEM 
KSU 
w PRINTER 
TEE’yNAL 
Transmit Data 
Receive Data 
RTS (Request to Send) 
CTS (Clear to Send) 
6 DSR (Data Set Ready) 
6 
7 GND 
7 
DTR (Data Terminal Ready) 
RS-232C PINOUT 
Data Communication Requirements are: 
A) Serial Port Compatible 
B) ASCII Code Compatible 
C) 8 Data Bits and 1 Stop Bit 
D) No Parity 
Figure 500.2 - RS232C Connections  

Page 59

STARPLUS@ 616 FLEX KEY TELEPHONE SYSTEM 
Table 500.2 SMDR Printout 
The SMDR feature provides detailed records of all outgoing and/or incoming, long distance only or all calls 
exceeding 30 seconds. This feature is enabled or disabled in system programming. By default, SMDR is not 
enabled and is set to record long distance calls only. A printout format of 80 characters maximum or 29 
character maximum may be selected in system programming. The standard format is 69 characters on a 
single line. A 29...

Page 60

STARPLUS@ 616 FLEX KEY TELEPHONE SYSTEM 
TELEPHONE BASE PLAT 
MOUNTING PLATE 
63. 
HANDSET RETAINER 
CLIP 
. 
114” SCREWS 
PmDm;;yDs 
MOUNTED 
PHONES 
Figure 500.3 - Wall Mounting the Key Telephone 
ISSUE 1, JANUARY 1991 am-1 1  