Page 61
Operation Vidikron Vision Model 110 Owner’s Operating Manual 49 PREL IMINARY Picture Use the controls in the Picture Menu to calibrate your Vision 110 for optimum picture quality. The Vision 110 has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted, industry-recognized standards for optimal video performance and has implemented a training program for technicians and installers to use these...
Page 62
Operation 50 Vidikron Vision Model 110 Owner’s Operating Manual PREL IMINARY Although it may be possible to obtain satisfactory picture quality using the naked eye and regular program material, Vidikron recommends using the following calibration tools for best results: External test pattern source – Ovation Multimedia, Digital Video Essentials or AVIA test DVD or equivalent. A blue filter (provided with many test DVDs), for color level and tint adjustments. Connect your test pattern source to the...
Page 63
Operation Vidikron Vision Model 110 Owner’s Operating Manual 51 PREL IMINARY Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the one shown in Figure 4-3. Figure 4-3. Typical Gray Bar Pattern for Adjusting Contrast Select Contrast and press ENTER or SELECT. Adjust the contrast to a point just below which the white rectangle starts to increase in size. Color Saturation: On your external test pattern source, select a color bar pattern like the one shown in...
Page 64
Operation 52 Vidikron Vision Model 110 Owner’s Operating Manual PREL IMINARY Select Color and press ENTER or SELECT. While looking at the color bar pattern through a blue filter, adjust the color saturation level until the outermost (gray and blue) color bars appear to be a single shade of blue: Tint: Tint or “hue” is essentially the ratio of red to green in the color portion of the image. When tint is decreased, the image appears redder; when it is increased the image appears greener. To set the...
Page 65
Operation Vidikron Vision Model 110 Owner’s Operating Manual 53 PREL IMINARY Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Picture menu and press ENTER or SELECT. On your external test pattern source, select a pattern like the one shown in Figure 4-5. Adjust as needed, looking for white edges around the transitions from black to gray and differently-sized lines in the “sweep” patterns at the top and bottom. Lower the...
Page 66
Operation 54 Vidikron Vision Model 110 Owner’s Operating Manual PREL IMINARY Overscan: Image Overscan pushes the outside edge of the active picture area of the video signal out beyond the edge of the display area. Some television programs are produced based on the assumption that older television sets may not display the outer edges of the broadcast picture area. Over scan effectively trims away these inactive, outer edges and enlarges the remaining portion of the image to fill the display area....
Page 67
Operation Vidikron Vision Model 110 Owner’s Operating Manual 55 PREL IMINARY CalibrationUse the Calibration menu to perform advanced picture quality adjustments. This menu should be used by ISF-certified technicians only. To recall the ISF Night or ISF Day settings, select “ISF Night” or “ISF Day” from the ISF Presets menu (see page 54) or use the corresponding buttons on the remote control. ISF Night - Display Color: Use the Display Color settings to adjust the color balance at the projector...
Page 68
Operation 56 Vidikron Vision Model 110 Owner’s Operating Manual PREL IMINARY ISF Night - Input Color: The Input Color controls are similar to those in the Display Color menu (see above), but adjust the color balance of the incoming signal. These settings are also saved independently for each input. • Gain/Offset: Refer to ISF Night - Display Color, above. • Chroma Delay: use the Chroma Delay control to correct a mis-aligned image from a Composite, S-Video or Component video source. Chroma delay in...
Page 69
Operation Vidikron Vision Model 110 Owner’s Operating Manual 57 PREL IMINARY ServiceUse the Service menu to access advanced projector configuration settings. This menu should be used by ISF-certified technicians only. Test Video: Select Test Video from the Service Menu to access the internal test patterns on the Vision 110. Four patterns are available: Horizontal Ramp, Vertical Ramp, Color Bars 1 (solid bars) and Color Bars 2 (SMPTE “checkerboard” pattern). Press MENU to exit test pattern mode....
Page 70
Operation 58 Vidikron Vision Model 110 Owner’s Operating Manual PREL IMINARY Triggers: Select Triggers from the Service menu to configure the 12-volt trigger outputs. You can assign one or more trigger outputs to each aspect ratio. Those triggers are then activated by selecting that aspect ratio. If your projector is equipped with the Vidikron CineWide with AutoScope system, assign at least one trigger output (the same one to which the lens motor is connected) to the Cinema and IntelliWide 2.35...