    Technical 
    Service 
    -., Manual 
    ::::::::::::::;::::::::::::::::::::::::::::::::::::::::::~:::::::::::::::::::::::::::::::::::::::::::;:::::::::::::::::::::::::::::::: Connection 
    Procedures 
    ...... 
    ...... 
    STEP 12 
    CONNECTING THE 
    POWER FAIL TRANSFER UNITS 
    NOTE 
    Perform the following procedure only if you 
    wish to install the optional Power Fail Transfer 
    Unit. If such is the case, then this procedure 
    should be followed in lieu of Step 2. 
    CAUTION 
    Power should not yet bc applied to the KSUs. 
    Power Fail Transfer Unit Installation 
    NOTE 
    SW also the Power Fail Transfer Unit diagrani 
    in the System and Set Layout section. 
    a Mount five Power Fail Transfer Units in the upper 
    right comer of the plywood backboard.. 
    .- : 
    Conncct’.thc 2-donductor special cabld supplied - 
    with the 1st Power Fail Transfer Unit, as follows: 
    i.. At the expander KSU, connect one end of the 
    special cable to the connector lab&d POWER 
    FAIL. 
    ii. At the 1st Power Fail Transfer Unit, connect 
    the other end of the special cable into the con- 
    ncctor labclcd CNK. c Connect the 2-conductor special cable supplied 
    with the 2nd Power Fail Tnnsfcr Unit, as follows: 
    i At the 1st Power Fail Transfer Unit, connect 
    one end of the special cable to the connector 
    labeled CNJ. 
    ii. At the 2nd Power Fail Transfer Unit, connect 
    the other end of the special cable into the con- 
    nector iabclcd CNK. 
    d Connect the 2-conductor special cable supplied 
    with the 3rd Power Fail Trarsfcr Unit. as follows: 
    i At the 2nd Power Fail Transfer Unit, connccl 
    one end of the special cable to the connector 
    labclcd CNJ. 
    ii. Ai the 3rd Power Fail Transfer Unit, connccl 
    the other end of tic special cable into the con- 
    ncctor labclcd CNK. 
    e. , Connect the 2-condudtoi special cablc.supplicd 
    with the 4th Power Fail Transfer Unit, as follows: 
    i At the 3rd Power Fail Transfer Unit, connccl 
    one end of the special cable to the connccLor 
    labclcd CNJ. 
    ii. At the 4th Power Fail TransTcr Unit, connect 
    the other end of the special cable into ihc con- 
    nector labclcd CNK. 
    f: Connect the 2-conductor special cable supplied 
    with the 5th Power Fail Transfer Unit, as follows: 
    i. At the 4th Power Fail Transrcr Unit, connect 
    one end of the special cable to the connector 
    lab&d CNJ. 
    ii. 
    At the 5th Power Fail Transfer Unit, connect 
    the other end of the special cable into the con- 
    ncctor labclcd CNK. 
    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . _ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ................................... _ ...........,............................,,~..............~.,......~~~~~~  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..~................................................................................~........................~~.~~~~~............~~~~~.~~~...~~~.~...~.~ 
    f “‘. TRILLIUM ; ; . .’ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
    .. . 
    -Telephone 
    - 8 : * 
    Panther 2064 ‘ 
    Systems Page D-23  
    						
    							Connection 
    Procedures 
    :::::: 
    g. Install four 50-pin RJ21-to-modular adapters that 
    have 5 each RJ14 jacks and four 25-pair cables that 
    have male 5C-pin IU21 connectors on each end: 
    i. Install the 1st adapter on the 1st cable; the 
    other end of the cable plugs into the RJ21 con- 
    nector that carries incoming lines l- 10. 
    ii. Install the 2nd adapter on the 2nd cable; the 
    other end of the cable plugs into the master 
    KSU connector labeled CO1 to CO 10. 
    iii. Install the 3rd adapter on the 3rd cable; the 
    other end of the cable plugs into the RJ21 con- 
    nector that carries incoming lines 1 l-20. 
    iv. Install the 4th adapter on the 4th cable: the 
    other end of the cable plugs into the expander 
    KSU connector labeled CO1 1 to CO20. 1 
    ._ 
    Technical 
    Service 
    Manual 
    ; :: : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ._. . . . . . . . . . ._ . . . . . 
    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....... 
    h. Route incoming lines l-10 to the Power Fail 
    Transfer Units: 
    i Connect a 4-conductor modular cord between 
    the 1st adapter’s FU14 jack at which incoming 
    lines 1 and 2 are terminated and the 1st Power 
    Fail Transfer Unit jack labeled CO 1.2. 
    ii Connect a 4-conductor modular cord between 
    the 1st adapter’s RJ14 jack at which incoming 
    lines 3 and 4 are terminated and the 1st Power 
    Fail Transfer Unit jack labeled C03.4. 
    iii. Connect a 4-conductor modular cord between 
    the 1st adapter’s RJ14 jack at which incoming 
    lines 5 and 6 are terminated and the 2nd Power 
    Fail Transfer Unit jack labeled CO 1.2. 
    iv: Connect a 4-conductor modular cord between 
    the 1st adapter’s RJ14 jack at which incoming 
    lines 7 and 8 are terminated and the 2nd Power 
    Fail Transfer Unit jack labeled C0.3.4. 
    . -. 
    . . -, 
    v. Connect a 4-conductor modular cord between 
    the 1st adapter’s RJ14 jack at which incoming 
    lines 9 and 10 are terminated and the 3rd 
    Power Fail Transfer Unit jack labeled C01.2. 
    pant&r 2064‘ ” ... -’ 
    Paee D-24 ’ 
    TRILLIUM 
    Telephone 
    Systems 
    U  
    						
    							Technical 
    Service 
    Manual 
    -----------.- . . . . . . . . . ..--.._......- 
    Connection . 
    Procedures 
    . , 
    .j. Route the &KS fiorn the Power Fail Transfer Units 
    to the 2nd adapter  i Route incoming lines 11-20 to the- Power Fail 
    Transfer Units: 
    i Connect a 4-conductor modular cord between 
    the 3rd adapter’s RJ14 jack at which incoming 
    lines 11 and 12 are terminated and the 3rd 
    Power Fail Transfer Unit jack labeled C03.4. 
    ii. Connect a 4conductor modular cord between 
    the 3rd adapter’s RJ14 jack at which incoming 
    lines 13 and 14 are terminated and the 4th 
    Power Fail Transfer Unit jack labeled CO1 2. 
    iii. Connect a 4-conductor modular cord between 
    the 3rd adapter’s RJ14 jack at which incoming 
    lines 15 and 16 are terminated and the 4th 
    Power Fail Transfer Unit jack labeled C03.4. 
    iv. Connect a 4-conductor modular cord between . iv Connect a 4-conductor modular cord between 
    the 3rd adapter’s RJ14 jack at which incoming the 2nd Power Fail Transfer Unit jack labeled 
    lines 17 and 18 are terminated and the 5th 
    TK3.4 and the 2nd adapter’s RJ14 jack for 
    Power Fail Transfer Unit jack labeled C01.2. 
    lines 7 and 8 (the fourth jack). 
    v. Connect a 4-conductor modular cord between 
    the 3rd adapter’s RJ14 jack at which incoming 
    lines 9. and 10 are termmated and the 5th 
    Po$er.Fail Transfer Unitjack labeled C03.4. .’ i Connect a4-cqnductor modular cord between 
    the 1% Power Fail Transfer Unit jack labeled 
    TK1.2 and the 2nd adapter’s RJ14 jack for 
    lines 1 and 2 (the first jack). 
    ii Connect a 4tonductor modular cord between 
    the 1st Power Fail Transfer Unit jack labeled 
    TK3.4 and the 2nd adapter’s RJ14 jack for - 
    lines 3 and 4 (the second jack). i- 
    iii. Connect a 4-conductor modular cord between 
    the 2nd Power Fail Transfer Unit jack labeled 
    TK1.2 and the 2nd adapter’s RJ14 jack for 
    lines 5 and 6 (the third jack). 
    v. Connect a 4-conductor modular cord between 
    the 3rd Power Fail Transfer Unit jack labeled 
    . TKL2 and the 2nd adapter’s RJ14 jack for 
    lines 9’and 10 (the’fifth jack). 
    TRILLIUM 
    Telephone 
    Systems Panther 2064 
    Page D-25  
    						
    							:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::~::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .,. . . . . . . 
    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . * . . . . . . . :::::::::::::::::::::::::::::::::::::;::::::::::::::::::: 
    Connection Technical 
    Procedures 
    Service 
    Manual 
    ,,...............___............................i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
    ................................................................................................ ~ ...... 
    , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . * . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................................... > .’ 8 
    k. Route the lines from me Power Fail Transfer Units 1; ‘Install ‘tw’enty &ndurd telephones (2-wire sets) in 
    convenient or strategic locations. 
    to the 4th adapter 
    i. Connect a 4-conductor modular cord between 
    the 3rd Power Fail Transfer Unit jack labeled 
    TK3.4 and the 4th adapter’s RJ14 jack for lines 
    11 and 12 (the fmt jack). 
    ii. Connect a cl-conductor modular cord between 
    the 4th Power Fail Transfer Unit jack labeled 
    TK1.2 and the 4th adapter’s RJ14 jack for lines 
    13 and 14 (the second jack). 
    iii. Connect a 4-conductor modular cord between 
    the 4th Power Fail Transfer Unit jack labeled 
    TK3.4 and the 4th adapter’s RI14 jack for lines 
    15 and 16 (the third jack). 
    iv Connect a 4-conductor modular cord between 
    the 5th Power Fail Transfer Unit jack labeled 
    TK1.2 and the 4th adapter’s RJ 14 jack for lines 
    17 and 18 (the fourth jack). 
    ( v. Connect a 4-conductor modular cord between 
    the 5th Power Fail Transfer Unit jack labeled 
    . TK3.4 and,the 4th adapter’s RI.14 jack for lines 
    ’ 
    19 and 20 (the fifth jack)., m. Using 2-conductor, modular cords; connect the 
    ,- standard sets to the jacks labeled TlT through T4T . 
    on the 1st through the 5th Power Fail Transfer .c 
    Units. 
    Panther 2064 
    Page .D-26 TRILLIUM __ 
    Telephone 
    Systems  
    						
    							“:“““:z ::::::: .-.-zE:~::‘““‘“’ ............................................ . “:.:“:::..::~ y :::::::: ::: “:::;:::::::: ::::::::;::“““” .................. . 
    .... .............. ...... 
    “...“...“..................“......” ...... 
    . ...... 
    ........... . . ... ..-.............................” ........ 
    .““.” . ..“. ... ..” ............................ I “.............” .I.. .. . ......... . ..“. 
    . . .......... 
    . . ..- 
    - ... ...” 
    Technical 
    Service 
    -. 
    Manual Connection 
    Procedures . . -.........-....... . . . . . . . . . . . . . . . . ...” 
    .” . . . . . . . . . . . . . . . . . . . . . . ..“....... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ::y
    						
    							Connection 
    Procedures Technical 
    Service 
    Manual 
    :::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: 
    STEP 13 
    INSTALLING 
    AN EXTERNAL 
    AMPLIFIER/SPEAKER 
    If an external amplifier/speaker is to be installed at a given 
    station, the the standard station wiring and Set installation 
    procedures must be modified for that station as follows (see 
    also the diagram to the right): 
    a Instead of mounting a 4-conductor RJ14 jack at the 
    station location (see Step 3 l& mount a 6-conductor 
    RJ25 jack. 
    NOTE 
    The 4-conductor station wiring cable between 
    the 66-block terminals and the station wiring 
    jack still follows the details ‘given in the station 
    wiring table on pages D-5 through D-9 -with 
    the 4 wires still running from the same 66- 
    block terminals and-being installed color-to-. 
    color on the jack, green-to-green, red-to-red, 
    black-to-black, and yellow-to-yellow. 
    b. Connect the external amplifier to the blue and 
    white terminals of the RJ25 station wiring jack. 
    c Instead of using the 4-conductor modular cord sup- 
    plied with the Set (see Step 4 g), use a standard 6- 
    conductor modular cord to connect the Set to the 
    station wiring jack 
    NOTE 
    The external amplifier/speaker is now connect- 
    ed to the Set’s speaker terminals. 
    d Check to see that signaling and voice messages 
    normally heard over the Set’s speaker will now be 
    heard over the external amplifier/speaker. 
    e To return the Set to its normal operation, simply re- 
    place the 6-conductor cord between the Set and the 
    station wiring jack with the 4-conductor that was 
    originally supplied with the Set. 
    ::::: . . . . . . . . . . . . . . . . . . . . . . . . . . .,. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . _. . . . . . . . .... . 
    , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
    Connect Set 
    by Nwiw 
    6-conductor 
    modular cord 
    . 
    . . in here 
    L-- 
    I: 
    Panther.2064 ’ ’ ‘ TRILLIUM. 
    Pa’ge D-28 
    Telephone 
    Systems  
    						
    							* . . . . . . ..I..... f . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 
    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..................................................................................................... ” ................ :::::::” .::: :. __.__-._ -..-.- _...._ 
    Technical 
    Service 
    System and 
    . . Manual 
    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ................................................................ : ......_.._........._.... Set Layout 
    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . :“” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...” . . . . . . . . . . . ................................................................................ ::::::::::::::::::a:: ::::::::::::::::::::::: I’ ::::::: “::::: 
    Power cord 
    Master KSU 
    Connectors 1 & 2 -for 
    connecting the master and 
    expander KSUs together 
    (using the special cables 
    supplied with the units) 
    Non-Handsfree Set 
    DSS/BLF Unit Split 
    f36-bbck 
    TYPICAL MASTER KSU LAYOUT DIAGRAM (Standard Components only) 
    TRILLIUM 
    Telephone 
    Systems 
    Panther 2064 
    Page E-l  
    						
    							System and 
    Set Layout Technical 
    Service 
    Manual 
    . . . . . . . . . . . . . . . . . . ..L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..................................................................................................................................................... 
    ,............................................................... ~ . . . . . . . . . . . . . . . . . . . . . . . . . . . I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ........................................................... t .......................... 
    .’ 
    Non-Handsfree Set 
    DSS/BLF Unit Split 
    66-block 
    TYPICAL EXPANDER KSU LAYOUT DIAGRAM (Standard Components only) 
    TRILLIUM 
    Telephone 
    Systems  
    						
    							Technical 
    Service 
    Manual 
    System and. 
    Set Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . .................... 
    “.............................................................,...........................................,................................... ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::;::::::::::::::::::::::~::::::::::::::~ 
    > 
    8 
    I 
    -? 
    -AL- --. .-A .i. 12 AWG 
    copper 
    wire 
    ver cora 
    \ 
    Mact~r K.SI I 
    3oor Answer Unit 
    ‘I / 6- mductor ’ 
    cord 
    2-wire 
    cable c To f 
    Paging 
    From 
    music 
    RS-232 cable 
    (not supplied) 
    TYPICAL SYSTEM LAYOUT DIAGRAM (Optional and External Components only) 
    TRILLIUM 
    Telephone 
    Systems  
    						
    							System and 
    Set Layout 
    Technical 
    Service 
    Manual 
    . 
    ’ 
    . 
    19. Ringer 
    Volume 
    Switch  
    [ 1. Speaker 1 
    2. Speaker 
    Volume I 
    Control 
    3. Sfieaker 
    4. Jacks for 
    Handset 
    L 
    i 
    15. Line Keys 
    8 Indicators 
    14. Flash/ 
    Cancel Key 
    1 
    12. Intercdm 
    Key & In’dicator 
    SET LAYOUT DIAGRAM 
    Panther 2064 
    Page E-4 TRILLIUM ‘y _ 
    Telephone 
    Systems  
    						