Toshiba Strata Xii, Strata Xx General Description Manual
Here you can view all the pages of manual Toshiba Strata Xii, Strata Xx General Description Manual. The Toshiba manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 61
craH- 1u4 IlKa IALLAI IUN SECTION 100-020-250 JUNE 1983 Strata XII&xx POWER SUPPLY (EPSA-104) INSTALLATION TABLE OF CONTENTS PARAGRAPH SUBJECT PAGE 01 01.10 01.20 01.30 02 02.10 02.20 02.30 02.40 02.50 FIGURE TITLE PAGE 1 EPSA-104 .................................................... 1 2 TOGGLER ................................................... 1 3 INSTALLING TOGGLER ........................................ 1 4 TOGGLERPIN ................................................ 2...
Page 62
SECTION 100-020-250 ‘. JUNE 1983 01 GENERAL 01.01 The EPSA-104 is equipped with a built- in wall mounting bracket, as shown in Figure 1, to allow it to be mounted on a wall or other flat, vertical surface. , Spare Fuses FIGURE 1 -EPSA-104 01.02 Unpack and inspect the EPSA-104 and the enclosed hardware. Examine the package and make careful note of any visible damage. If any damage is found, bring it to the attention of the delivery carrier and make the proper claims. 01.03 Check the...
Page 63
ti%A-104 INS I ALLA I IUIY SECTION 100-020-250 JUNE 1983 with the mounting surface. If insertion is difficult, tap them lightly with a hammer. 01.22 Insert a toggler key into the small hole in the neck of each fastener, as shown in Figure 4. This should cause the anchor legs to “pop” open. Remove the toggler key. Spread Anchor Legs FIGURE 4-TOGGLER PIN 01.23 Thread the screws into the small holes in the center of the togglers. Leave approximately 3/1&inch clearance between the bottom of...
Page 64
-. _*. ._. .-.- .n .__#., ,“,. SECTION 106-020-250 JUNE 1983 02.05 The standby batteriez will not be re- connected unless: l The “Battery Override” switch (Figures 7 and 8) is placed in the ON position, or. . . . l The depleted batteries are replaced by a freshly charged pair and the “Battery Override” switch is turned on and then released. ’ 02.06 The PBBU also contains circuitry to provide the charge current neces%ary to maintain the batteries at a satisfactory level of charge while the...
Page 65
EPSA-104 INS IALLATIUN SECTION 100-020-250 JUNE 1983 l “PBBU-3 REV A”-decal to be placed on the front of the EPSA. l ‘WARNING”-warning tag for attachment to the 115 VAC power cord. 02.08 In addition to the PBBU kit, these items are needed to install a PBBU. l Two Batteries-lead-acid, maintenance-free au- tomobile batteries (80 amp/hr maximum) are recommended. The procedures in Paragraph 02.40 assume batteries with side-mounted terminals are used. l Battery Rack & Separator-a battery rack...
Page 66
02.16 Locate and trace the multi-wire harness 02.23 Slip the PBBU fuse holder and battery in the lower portion of the EPSA (the area away override button through their respective ports from the built-in mounting bracket). The harness in the control panel (Figure 11). The PBBU mount- originates from the transformer and the terminals ing bracket should be flush against the rear of the mounted in the control panel. This harness ter- control panel. The harness should flow around minates in a...
Page 67
EPSA-104 INSTALLATION SECTION 100-020-250 JUNE 1983 1 02.41 Select a location for the batteries near the power supply. The loop length of the cable connecting them to the power supply will de- termine the minimum gauge wire which can be used in the cable. See Table A. DANGER!: itive terminal of battery #2 (see Figure 13). 02.49 Connect the two batteries with the single-wire cable-one end to the positive terminal on battery if1 and the other end to the negative terminal on battery #2 (Figure...
Page 68
tr3H- 1~4 11x3 IHLCH~ IUIY SECTION 100-020-250 JUNE 1983 02.53 Replace the terminal strip cover and test the STRATA system functions under both AC and battery back-up power. IMPORTANT: When testing is complete, make certain that the battery override button is in the OFF position and that the AC ON indicator i? lit. . . -7-
Page 69
TOSHIBA SYSTEM PRACTICES ELECTRONJC KEY TELEPHONE SYSTEM SYSTEM PROGRAMMING SECTION 100-020-300 JUNE 1983 S&ii&a XII&XX SYSTEM PROGRAMMING
Page 70
PARAGRAPH SUBJECT _ PAGE 01 02 02.00 02.10 02.20 02.30 02.40 * 02.50 02.60 02.70 02.80 03 03.00 SYSTEM PROGRAMMING SECTION 100-020-300 JUNE 1983 - TABLE OF CONTENTS TABLE of CONTENTS. ........................................... i ILLUSTRATION LIST. ........................................... ii INTRODUCTION ................................................ 1 PROGRAMMING PROCEDURES ................................... 1 General...