a) External Page--the relay is activated when- ever the external page circuit is accessed. A “make” contact is provided for control of background music on external page. This is- required only when an external page amplifier is used. b) Night Relay Service-relay will provide a dry contact at the NR terminals on the front of the MPRU PCB. A strap option on the MPRU allows the NR relay to function in one of two modes: 1) Answering Machine Control- if the strap remains intact, the relay is oper-...
Page 22
TOSHIBA SYSTEM PRACTICES ELECTRONIC KEY TELEPHONE SYSTEM INSTALLATION SECTION 100-020-200 JUNE 1983 SGrata +’ - XII&xx INSTALLATION
Page 23
TOSHIBA SYSTEM PRACTICES INS IALLAI IUN ELECTRONIC KEY TELEPHONE SYSTEM INSTALLATlbN SECTION 100-020-200 JUNE 1983 PARAGRAPH TABLE OF CONTENTS SUBJECT PAGE TABLEofCONTENTS ................................................... ..i ILLUSTRATION LIST ii .................................................... GENERAL ...................................................................................................................... PACKING.. ; MKSU LOCATION REQUIREMENTS...
Page 24
TOSHIBA SYSTEM PRACTICES ELECTRONIC KEY TELEPHONE SYSTEM INSTALLATlON ILLUSTRATION LIST FIGURE SUBJECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 IN3 IHLLAI IUN SECTION 100-020-200 JUNE 1983 PAGE CRDUBATTERYSTRAP.. ........................................ .._ ... 1 AMMUBArrERYSTRAP ............................................... 1 MSMUBATTERYSTRAP...
Page 25
INSTALLATION SECTION 100-020-200 JUNE 1983 01 GENERAL 01.01 This section describes the installation precedures necessary to ensure proper operation of the STRATA XII & XX systems. The instal- lation procedures for the two systems vary only in relation to size; all other factors are the same. 02 PACKING 02.01 When a STRATA system is received, examine all packages and carefully note any visible damage. If any damage is found, bring it to the attention of the delivery carrier and make the...
Page 26
INSTALLATION SECTION 100-020-200 JUNE 1983 FIGURE 3-MSMU BATTERY STRAP 03 MKSU LOCATION REQUIREMENTS 03.00 Power Requirements 03.01 The STRATA MKSU (both XII & XX) requires 24 VDC. This is provided by the power supply (EPSA), which in turn requires power from a grounded 115 VAC outlet. The outlet should be separately fused and rated at 15 amps. 03.02 The same EPSA power supply is used with both STRATA systems. 03.03 The 54-inch cord provided to connect the EPSA to the MKSU dictates the...
Page 27
INSTALLATION SECTION 100-020-200 JUNE 1983 1 Drilling Template 1 Back Plate 1 Side Plate A 1 Side Plate B 2 Side Angles 12 Binding-head Screws 04.22 Be certain that all parts are included before proceeding. 04.23 In addition to those items supplied in the MKWM kit, six fasteners, suitable for the type of wall chosen, must be supplied by the installer. The fasteners will the wall mount bracket and A typical fastener would be: l/4-in. Toggle Bolt l/4-in. Molly Fastener l/4-in. Lag...
Page 28
INSTALLATION SECTION 100-020-200 JUNE 1983 d) e) holes in the back plate. Tighten them loosely so that approximately 3/8-in. gap remains be- tween the head of the fastener and the mount- ing surface. install the wall mount assembly by slipping the two keyholes in the back plate over the two fasteners installed in Step C. Install the lower two fasteners in the back plate and tighten all four fasteners securing the wall mount assembly. 04.27 The MKSU must be prepared for wall mounting by...
Page 29
b) : c) d) e) f) Cl) SECTION 100-020-200 JUNE 1983 Loosely attach the side angles to the lower system operations and battery-protected RAM sides of the MKSU by sliding their keyholes for system data storage are located on the over the previously mentioned screws. AMMU. Ensure that the side angles are properly aligned with the holes in the mounting bracket and that the two top holes are aligned with the holes in the mounting surface. CRDU: Fasten the MKSU to the mounting surface loosely,...
Page 30
INSTALLATION SECTION 100-020-200 JUNE 1983 (each system uses only one MDSU). The MDSU serves up to two fully functional DSS consoles and two DSS consoles which are used as Busy Lamp Field terminals only. MSMU/S&J: The SCNU is required and mounts directly on the MSMU to form a single unit. This optional PC6 serves as an interface between the MKSU and a printer or storage device used for the SMDR feature. The PCB is equip- ped with an RS 232C-type interface (one per system). MOPU (MF/DP or...