Page 51
1) Lock in the SET switch on the MCAU: * The MCAU LED and MW/FL LED on station 17 will go on. 2) Depress IFJ key on station 17: l SPKR LED will light steadily. 3) Dial m 4 m on dial pad: l SPKR LED will flash continuously. 4) Depress the following keys: l II (1 m -1 -the correspond- ing LEDs will light. 5) Depress the [I key: l All station 17 LEDs (except MW/FL) will go off. 6) Release the SET switch on the MCAU: l The MCAU LED and MW/FL LED on station 17 will go off. 10.14 To clear...
Page 52
INSTALLATION SECTION 100-020-200 JUNE 1983 INC: Selects the data (hour, minute, day, etc.) for the item number selected by the MOD switch and displayed by LED #l. LED #2 displays data selected by the INC switch. i Depressing the INC switch once increments data by 1. l Depressing and holding the INC switch causes data to increase continuously until the INC switch is released. :i -I: Y! MSMU : -7 .1 I t. -, FIGURE 40-MSMU FACEPLATE 10.25 To set clock and calendar: 1) Verify that the...
Page 53
b) 4 d) 4 f) l SPKR LED: on steady l Listen for intercom dial tone via EKT speaker Adjust speaker volume with the volume control on the rear right side of the EKT. Depress the [cl] key: . CO 1 LED: l-use flash .SPKR LED: on steadv l Listen for CO/PBX d*ial tone via EKT speaker Dial any digit (2~9) on the dial pad and dial tone will stop. Depress the m key: l Listen for circuit break followed by dial tone after approximately 2 seconds. Depress each a key in order on every EKT, the...
Page 54
INSTALLATION SECTION 100-020-200 JUNE 1983 11.03 This completes the station functional check; repeat the procedure for all stations in the system. 11 .lO Off Premise Extension / Conventional Telephone Functional Check 11.11 Perform the following test procedure at each Off Premise Extension/Conventional Telephone (OPX) location: a) Lift the OPX handset and listen for intercom dial tone. 1120 OPL Circuit Functional Check b) Dial the number of another station: l Dial tone will stop when the...
Page 55
l Verify that a 2-way voice connection is established. I) Depress OPL CO line key on an EKT: l Verify that the privacy feature prevents access. m) Go on-hook at the OPL telephone. n) Make another incoming call to the OPL CO line. o) Answer the call using an EKT: l Verify that a 2-way voice connection is established. p) Lift the OP L telephone handset: l Verify that a 3-way voice connection is established. q) Go on-hook at both stations. i) 11.30 SMDR Feature Functional Check 11.31 Perform...
Page 56
INSTALLAl IWN SECTION 100-020-200 JUNE 1983 11.40 Feature Check 11.41 Verify that all system features function properly per Section 100-020-400, Operating Procedures. 12 MISCELLANEOUS EQUIPMENT CONNECTIONS 12.00 Wiring Connections 12.01 All connections to miscellaneous equip- ment are made via the barrier strip mounted on the front of the MPRU PCB, as shown in Figure 43. STU2 MINU 1 a 1 x 0 4MSTl . I L MINU 0 MOU 0 Ol3Gh-l @ @@ MOPU TEL 0 #2 MOPU FIGURE 43-MPRU CONNECTION...
Page 57
INS IALLAI ION SECTION 100-020-200 JUNE 1983 See Paragraph 12.80 for the correct volume setting sequence. 12.50 External Amplifier Connection 12.51 If more power is required than the MPRU amplifier can deliver, a customer-provided external amplifier may be connected to the 8/600 terminals on the MPRU (connect external speakers to the external amplifier). 12.52 Determine which output impedance is most suitable for the amplifier being used, and make the selection with the SW2 switch on the...
Page 58
INSTALLATION SECTION 100-020-200 JUNE 1983 I- (0 I 0 ( T -J I FIGURE 46-VOLUME SETTING CONTROLS 1 I 12.82 Adjust the MOH level first using the following procedure: 1) 2) 3) 4) 5) 6) Set the MOH volume control on the front of the MPRU to its lowest level (counter- clockwise). Lift the handset on one station and call another station using 2 CO/PBX lines. At the called station, put the incoming call on hold, and listen on the handset (not the speaker) of the calling EKT. Using...
Page 59
ground noise that is about average for that particular installation. 2) 3) Disconnect the CO call and activate BGM at the EKT using the m key. Using only the BGM volume control on the front of the MPRU, adjust the BGM to a com- fortable level. Do not use the EKT volume control. 12.90 Night Relay Service 12.91 As an option, STRATA can provide a dry contact for the purpose of controlling an external loud ringing bell (or similar device) or an answering machine when the system is in the “Nite”...
Page 60
TOSHIBA SYSTEM PRACTICES ELECTRONIC KEY TELEPHONE SYSTEM TOSHIBA PUBLICATIONS SECTION 100-020-250 JUNE 1983 Strata XII&XX POWER SUPPLY (EPSA-104) INSTALLATION